CoChat

Use of Indium-111–Labeled Hepatocytes to Determine the Biodistribution of Transplanted Hepatocytes Through Portal Vein Infusion

BOHNEN, NICOLAAS I., CHARRON, MARTIN, REYES, JORGE, RUBINSTEIN, WENDY, STROM, STEPHEN C., SWANSON, DENNIS, TOWBIN, RICHARD · 2000 · Clinical Nuclear Medicine
Cited by 69

The DOI matches its Crossref record.

Abstract

PURPOSE: Hepatocyte transplantation is useful for ex vivo gene therapy and liver repopulation. Methods for hepatic reconstitution were recently developed, but hepatocyte transplantation systems must be optimized. The authors report their experience with In-111 oxyquinolone labeling of a test dose of hepatocytes (108 cells) for noninvasive assessment of the biodistribution of transplanted hepatocytes in a 5-year-old child with omithine transcarbamoylase deficiency. MATERIALS AND METHODS: Donor hepatocytes (approximately 108) were radiolabeled using a commercially available In-111 oxyquinolone solution (specific activity of 1 mCi/ml). RESULTS: The overall labeling efficiency was 36.4%. A final dose of approximately 290 ,uCi of the In-111-labeled hepatocytes in 10 ml serum-free phosphate-buffered saline was infused percutaneously into the portal vein approximately 2.5 hours after their preparation. The study was performed 3 hours before cell transplantation (109 cells). Quantitative analysis of the biodistribution of In-111-labeled hepatocytes indicated that cells were predominantly localized in the liver immediately after portal vein-infused transplantation. The predominant hepatic distribution was persistent for as long as 7 days after the procedure, with an average liver-to-spleen ratio of 9.5 to 1. No significant pulmonary radiotracer uptake was present. CONCLUSION: These results indicate that In-111 labeling of hepatocytes is useful for the short-term noninvasive analysis of the biodistribution of transplanted hepatocytes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003072-200006000-00012

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 69

Metadata

Authors
BOHNEN, N. I., CHARRON, M., REYES, J., RUBINSTEIN, W., STROM, S. C., SWANSON, D., & TOWBIN, R.
Venue
Clinical Nuclear Medicine
Published
2000-06
Volume
25
Issue
6
Pages
447-450
ISSN
0363-9762 (ISSN-L)
OpenAlex
W2325553041
Cited by
69
References
0
FWCI
0.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of Indium-111–Labeled Hepatocytes to Determine the Biodistribution of Transplanted Hepatocytes Through Portal Vein Infusion. https://app.cochat.ai/papers/10.1097/00003072-200006000-00012
The paper
BOHNEN, N. I., CHARRON, M., REYES, J., RUBINSTEIN, W., STROM, S. C., SWANSON, D., & TOWBIN, R. (2000). Use of Indium-111–Labeled Hepatocytes to Determine the Biodistribution of Transplanted Hepatocytes Through Portal Vein Infusion. Clinical Nuclear Medicine. https://doi.org/10.1097/00003072-200006000-00012

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.