Natural History of Autografts and Allografts
The DOI matches its Crossref record.
Abstract
The clinical outcome of bone grafting procedures depends on many factors, including type and fixation of the bone graft as well as the site and status of the host bed. Bone grafts serve one or both of two main functions, as a source of osteogenetic cells and as a mechanical support. Autografts, both cancellous and cortical, are usually implanted fresh and are often osteogenetic, whether by providing a source of osteoprogenitor cells or by being osteoinductive. The latter is a process whereby the transplanted tissue induces mesenchymal cells of the recipient to differentiate into osteoblastic cells. Cortical grafts, whether autogeneic or allogeneic, at least initially act as weight-bearing space fillers or struts. All bone grafts are initially resorbed, but cancellous grafts are completely replaced in time by creeping substitution, while cortical grafts remain an admixture of necrotic and viable bone for a prolonged period of time. The three-dimensional framework, which supports invasion of the bone grafts by capillaries and osteoprogenitor cells, termed “osteoconduction,” is another important function of both autografts and allografts. Fresh allografts are more slowly and less completely replaced by host bones because they invoke both local and systemic immune responses that diminish or destroy the osteoinductive and conductive processes. Although freezing or freeze-drying of allografts improves acceptance, their failure rate is still too high. These processes are also influenced by the vascularity and composition of the host bed. Thus, the interaction of the host and the bone graft determines the success of these procedures, which ultimately is to provide a mechanically efficient support structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wei, G., & Ma, P. X. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.12.005 · Cited by 1,271
Bone Graft Materials: An Overview of the Basic Science
Bauer, T. W., & Muschler, G. F. (2000) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200002000-00003 · Cited by 998
Ma, P. X., Zhang, R., Xiao, G., & Franceschi, R. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200102)54:2<284::aid-jbm16>3.0.co;2-w · Cited by 429
Hollinger, J. O., Brekke, J., Gruskin, E., & Lee, D. (1996) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199603000-00008 · Cited by 405
Sawin, P. D., Traynelis, V. C., & Menezes, A. H. (1998) · Journal of Neurosurgery · doi:10.3171/jns.1998.88.2.0255 · Cited by 373
Biological principles of bone graft healing
Cypher, T. J., & Grossman, J. P. (1996) · The Journal of Foot and Ankle Surgery · doi:10.1016/s1067-2516(96)80061-5 · Cited by 294
Preparation and characterization of nano‐hydroxyapatite/chitosan composite scaffolds
Kong, L., Gao, Y., Cao, W., Gong, Y., Zhao, N., & Zhang, X. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30414 · Cited by 278
Persistent Iliac Crest Donor Site Pain: Independent Outcome Assessment
Heary, R. F., Schlenk, R. P., Sacchieri, T. A., Barone, D., & Brotea, C. (2002) · Neurosurgery · doi:10.1097/00006123-200203000-00015 · Cited by 268
Three-dimensional degradable porous polymer-ceramic matrices for use in bone repair
Devin, J. E., Attawia, M. A., & Laurencin, C. T. (1996) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856296x00435 · Cited by 174
Anjaneyulu, U., Priyadarshini, B., Nirmala Grace, A., & Vijayalakshmi, U. (2017) · Journal of Sol-Gel Science and Technology · doi:10.1007/s10971-016-4243-5 · Cited by 67
Metadata
- Authors
- GOLDBERG, V. M., & STEVENSON, S.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1987-12
- Volume
- 225
- Pages
- 7-16
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W4252530191
- Cited by
- 436
- References
- 0
- FWCI
- 0.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.