Mechanism and Clinical Significance of Wear Debris-Induced Osteolysis
Abstract
Loosening of joint replacement components is often multifactorial. The quality of initial fixation is very important to the outcome of the arthroplasty and is often a factor in short-term and long-term failure. This paper discusses another important factor of implant loosening, namely wear debris induced osteolysis. Macrophages activated by the phagocytosis of particulate wear debris are the key cells in this process, which can potentially occur in any implant system regardless of implant design or fixation mode. This is because each implant system creates wear debris from the articulating surfaces and the interfaces. The clinical consequences of wear debris cover a broad spectrum from radiolucencies to massive osteolysis and implant failure. For this reason, the reduction of wear debris should be a primary goal of orthopedic research in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The operation of the century: total hip replacement
Learmonth, I. D., Young, C., & Rorabeck, C. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60457-7 · Cited by 2,848
Biomedical applications of polymer-composite materials: a review
Ramakrishna, S., Mayer, J., Wintermantel, E., & Leong, K. W. (2001) · Composites Science and Technology · doi:10.1016/s0266-3538(00)00241-4 · Cited by 1,642
Biological reactions to wear debris in total joint replacement
Ingham, E., & Fisher, J. (2000) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411001535219 · Cited by 708
Raphel, J., Holodniy, M., Goodman, S. B., & Heilshorn, S. C. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.01.016 · Cited by 674
Grey Goo on the Skin? Nanotechnology, Cosmetic and Sunscreen Safety
Nohynek, G. J., Lademann, J., Ribaud, C., & Roberts, M. S. (2007) · Critical Reviews in Toxicology · doi:10.1080/10408440601177780 · Cited by 644
Metadata
- Authors
- AMSTUTZ, H. C., CAMPBELL, P., KOSSOVSKY, N., & CLARKE, I. C.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1992-03
- Volume
- 276
- Issue
- 276
- Pages
- 7???18
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2073573464
- Cited by
- 670
- References
- 0
- FWCI
- 20.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanism and Clinical Significance of Wear Debris-Induced Osteolysis. https://app.cochat.ai/papers/10.1097/00003086-199203000-00003
- The paper
- AMSTUTZ, H. C., CAMPBELL, P., KOSSOVSKY, N., & CLARKE, I. C. (1992). Mechanism and Clinical Significance of Wear Debris-Induced Osteolysis. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-199203000-00003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.