Mechanism and Clinical Significance of Wear Debris-Induced Osteolysis
The DOI matches its Crossref record.
Abstract
Loosening of joint replacement components is often multifactorial. The quality of initial fixation is very important to the outcome of the arthroplasty and is often a factor in short-term and long-term failure. This paper discusses another important factor of implant loosening, namely wear debris induced osteolysis. Macrophages activated by the phagocytosis of particulate wear debris are the key cells in this process, which can potentially occur in any implant system regardless of implant design or fixation mode. This is because each implant system creates wear debris from the articulating surfaces and the interfaces. The clinical consequences of wear debris cover a broad spectrum from radiolucencies to massive osteolysis and implant failure. For this reason, the reduction of wear debris should be a primary goal of orthopedic research in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The operation of the century: total hip replacement
Learmonth, I. D., Young, C., & Rorabeck, C. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60457-7 · Cited by 2,848
Biomedical applications of polymer-composite materials: a review
Ramakrishna, S., Mayer, J., Wintermantel, E., & Leong, K. W. (2001) · Composites Science and Technology · doi:10.1016/s0266-3538(00)00241-4 · Cited by 1,642
Biological reactions to wear debris in total joint replacement
Ingham, E., & Fisher, J. (2000) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411001535219 · Cited by 708
Raphel, J., Holodniy, M., Goodman, S. B., & Heilshorn, S. C. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.01.016 · Cited by 674
Grey Goo on the Skin? Nanotechnology, Cosmetic and Sunscreen Safety
Nohynek, G. J., Lademann, J., Ribaud, C., & Roberts, M. S. (2007) · Critical Reviews in Toxicology · doi:10.1080/10408440601177780 · Cited by 644
Panilaitis, B., Altman, G. H., Chen, J., Jin, H.-J., Karageorgiou, V., & Kaplan, D. L. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00158-3 · Cited by 570
The influence of weight-bearing on the measurement of polyethylene wear in THA
Smith, P. N., Ling, R. S. M., & Taylor, R. (1999) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.81b2.9154 · Cited by 464
Current Concepts Review - Wear in Total Hip and Knee Replacements*
SCHMALZRIED, T. P., & CALLAGHAN, J. J. (1999) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199901000-00016 · Cited by 395
Composition and morphology of wear debris in failed uncemented total hip replacement
Shanbhag, A., Jacobs, J., Glant, T., Gilbert, J., Black, J., & Galante, J. (1994) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.76b1.8300684 · Cited by 387
Isolation of predominantly submicron‐sized UHMWPE wear particles from periprosthetic tissues
Campbell, P., Ma, S., Yeom, B., McKellop, H., Schmalzried, T. P., & Amstutz, H. C. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290118 · Cited by 352
Self-citationUrban, R. M., Jacobs, J. J., Gilbert, J. L., & Galante, J. O. (1994) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199409000-00009 · Cited by 337
EARLY OSTEOLYSIS FOLLOWING SECOND-GENERATION METAL-ON-METAL HIP REPLACEMENT
PARK, Y.-S., MOON, Y.-W., LIM, S.-J., YANG, J.-M., AHN, G., & CHOI, Y.-L. (2005) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200507000-00014 · Cited by 322
Nanotechnology, Cosmetics and the Skin: Is There a Health Risk?
Nohynek, G. J., Dufour, E. K., & Roberts, M. S. (2008) · Skin Pharmacology and Physiology · doi:10.1159/000131078 · Cited by 315
Green, T. R., Fisher, J., Matthews, J. B., Stone, M. H., & Ingham, E. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200009)53:5<490::aid-jbm7>3.0.co;2-7 · Cited by 310
McKELLOP, H., SHEN, F.-W., LU, B., CAMPBELL, P., & SALOVEY, R. (2000) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200012000-00004 · Cited by 264
Self-citationRisk Factors Affecting Outcome of Metal-on-Metal Surface Arthroplasty of the Hip
Beaul??, P. E., Dorey, F. J., LeDuff, M., Gruen, T., & Amstutz, H. C. (2004) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200401000-00015 · Cited by 254
Self-citationA unified theory of wear for ultra-high molecular weight polyethylene in multi-directional sliding
Wang, A. (2001) · Wear · doi:10.1016/s0043-1648(00)00522-6 · Cited by 245
Amorphous carbon as a bio-mechanical coating — mechanical properties and biological applications
Tiainen, V (2001) · Diamond and Related Materials · doi:10.1016/s0925-9635(00)00462-3 · Cited by 245
Failed innovation in total hip replacement: Diagnosis and proposals for a cure
Huiskes, R. (1993) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679308994602 · Cited by 215
Lee, S., Brennan, F. R., Jacobs, J. J., Urban, R. M., Ragasa, D. R., & Glant, T. T. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150107 · Cited by 201
“It is hypothesized that the formation of this aggressive granulomatous soft tissue is a response to particulate wear debris derived from the prosthetic material and (when present) bone cement (2,13).”
BackgroundIngram, J. H., Stone, M., Fisher, J., & Ingham, E. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.054 · Cited by 181
Al Sheheri, S. Z., Al-Amshany, Z. M., Al Sulami, Q. A., Tashkandi, N. Y., Hussein, M. A., & El-Shishtawy, R. M. (2019) · Designed Monomers and Polymers · doi:10.1080/15685551.2019.1565664 · Cited by 170
“Additionally, when UHPE implants are in relative motion with metal or ceramic material, it generates wear debris which migrates to tissues that cause osteolysis [83].”
BackgroundOsteolysis in Association with a Total Hip Arthroplasty with Ceramic Bearing Surfaces*
YOON, T. R., ROWE, S. M., JUNG, S. T., SEON, K. J., & MALONEY, W. J. (1998) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199810000-00007 · Cited by 169
Oparaugo, P. C., Clarke, I. C., Malchau, H., & Herberts, P. (2001) · Acta Orthopaedica Scandinavica · doi:10.1080/000164701753606644 · Cited by 166
Self-citationAn Overview of High-Entropy Alloys as Biomaterials
Castro, D., Jaeger, P., Baptista, A. C., & Oliveira, J. P. (2021) · Metals · doi:10.3390/met11040648 · Cited by 161
“In total hip arthroplasty (THA), wear is seen as a major cause of osteolysis, leading to bone loss due to the foreign-body autoimmune response, caused by the implant’s wear debris [23,24].”
BackgroundYamada, C., Ho, A., Akkaoui, J., Garcia, C., Duarte, C., & Movila, A. (2021) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2021.111503 · Cited by 33
Applications of nanobioceramics to healthcare technology
Feng, J., & Thian, E. S. (2013) · Nanotechnology Reviews · doi:10.1515/ntrev-2012-0065 · Cited by 16
Metadata
- Authors
- AMSTUTZ, H. C., CAMPBELL, P., KOSSOVSKY, N., & CLARKE, I. C.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1992-03
- Volume
- 276
- Issue
- 276
- Pages
- 7???18
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2073573464
- Cited by
- 670
- References
- 0
- FWCI
- 20.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.