Intense Granulomatous Inflammatory Lesions Associated With Absorbable Internal Fixation Devices Made of Polyglycolide in Ankle Fractures
The DOI matches its Crossref record.
Abstract
Since absorbable internal fracture fixation devices made of polyglycolide have been increasingly used clinically, a peculiar type of complication has emerged. After an initially uneventful course, a local nonbacterial inflammatory reaction appears two to four months after the operation, resulting in a copiously discharging sinus on the skin. A series of 286 patients with unimalleolar or bimalleolar fractures were treated by open reduction and internal fixation using cylindrical rods made of polyglycolide. Among these there occurred 18 nonbacterial inflammatory tissue responses (6.3% of the total) requiring surgical drainage. Six patients had an intense reaction necessitating repeated surgical measures and inpatient management. The hospital stay of these patients averaged 18 days. The mean duration of the discharge from the lesions was 10.8 weeks. Microscopic examination of biopsy specimens showed a nonspecific foreign-body reaction composed mainly of neutrophilic polymorphonuclear leukocytes and foreign-body giant cells phagocytizing the polymer debris left behind by the decomposing implants. On roentgenograms, osteolytic increase of the diameter of the implant channels was observed, but the bony union of the fracture seemed not to be disturbed. Thus the factors increasing the susceptibility of some individuals to this complication remain unknown.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In clinical studies where PGA was used as fracture fixation, foreign-body responses or osteolytic reactions have been reported”
From Biodegradable synthetic polymers for tissue engineering (2003) · cites this paper as Böstman, 1992
Citations
Cites
Still being checked.
Cited by
Items 101–186 of 186
Liu, G., Chen, L., Gong, M., Xing, F., & Xiang, Z. (2019) · The Journal of Foot & Ankle Surgery · doi:10.1053/j.jfas.2019.01.015 · Cited by 22
Yang, J.-W., Park, H.-J., Yoo, K.-H., Chung, K., Jung, S., Oh, H.-K., Kim, H.-S., & Kook, M.-S. (2014) · Head & Face Medicine · doi:10.1186/1746-160x-10-15 · Cited by 22
Blow-out fractures in children: six years’ experience
Theologie‐Lygidakis, N., Iatrou, I. A., & Alexandridis, C. (2006) · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · doi:10.1016/j.tripleo.2006.08.031 · Cited by 21
New Sutures and Suture Anchors in Sports Medicine
Barber, F. A., Boothby, M. H., & Richards, D. P. (2006) · Sports Medicine and Arthroscopy Review · doi:10.1097/00132585-200609000-00010 · Cited by 21
Schmitz, J. P., Lemke, R. R., Zardeneta, G., Hollinger, J. O., & Milam, S. B. (2000) · Journal of Oral and Maxillofacial Surgery · doi:10.1053/joms.2000.8216 · Cited by 26
Acute and Chronic Syndesmotic Instability
Stenquist, D. S., Ye, M. Y., & Kwon, J. Y. (2020) · Clinics in Sports Medicine · doi:10.1016/j.csm.2020.06.002 · Cited by 17
MRI study of bioabsorbable poly-L-lactic acid devices used for fixation of fracture and osteotomies
Marumo, K., Sato, Y., Hidehiko, S., & Kurosaka, D. (2006) · Journal of Orthopaedic Science · doi:10.1007/s00776-005-0989-2 · Cited by 17
Rano, J. A., Savoy‐Moore, R. T., & Fallat, L. M. (2002) · The Journal of Foot & Ankle Surgery · doi:10.1016/s1067-2516(02)80004-7 · Cited by 17
Ekholm, M., Hietanen, J. H. P., Tulamo, R., Muhonen, J., Lindqvist, C., Kellomäki, M., & Suuronen, R. (2003) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1025642912270 · Cited by 16
Sadeghi-Avalshahr, A., Khorsand-Ghayeni, M., Nokhasteh, S., Shahri, M. M., Molavi, A. M., & Sadeghi-Avalshahr, M. (2017) · Polymer Bulletin · doi:10.1007/s00289-017-2158-0 · Cited by 16
Atkinson, P. J., Lancaster, R. L., Atkinson, T., Arnoczky, S. P., Haut, R. C., & Weisbrode, S. E. (1998) · The Journal of Foot & Ankle Surgery · doi:10.1016/s1067-2516(98)80010-0 · Cited by 17
Bone response to polymers based on poly-lactic acid and having different degradation times
Merolli, A., Gabbi, C., Cacchioli, A., Ragionieri, L., Caruso, L., Giannotta, L., & Leali, P. T. (2001) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1017912716351 · Cited by 15
Particulate retrieval of hydrolytically degraded poly(lactide-co-glycolide) polymers
Cordewener, F. W., Dijkgraaf, L. C., Ong, J. L., Agrawal, C. M., Zardeneta, G., Milam, S. B., & Schmitz, J. P. (2000) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(200004)50:1<59::aid-jbm9>3.0.co;2-m · Cited by 16
Pawaskar, A., Kekatpure, A., Cho, N. S., Rhee, Y. G., & Jeon, I. (2015) · Indian Journal of Orthopaedics · doi:10.4103/0019-5413.152452 · Cited by 14
Tissue Engineering of Skeletal Muscle
Klumpp, D., Raymund, H., & Beier, J. (2011) · InTech eBooks · doi:10.5772/21197 · Cited by 12
Park, M. C., & Tibone, J. E. (2006) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2005.06.030 · Cited by 11
A novel, resorbable suture anchor: Pullout strength from the human cadaver greater tuberosity
Stanford, R., Harrison, J., Goldberg, J. A., Sonnabend, D. H., Alvis, M. R., & Walsh, W. R. (2001) · Journal of Shoulder and Elbow Surgery · doi:10.1067/mse.2001.113085 · Cited by 12
Peltoniemi, H. H. (2000) · Helda - University of Helsinki Institutional Repository · Cited by 16
Rodrigues, S. M. D. S., Borges, M. F., de Magalhães, D., & Ruggiero, R. (2021) · Research Society and Development · doi:10.33448/rsd-v10i16.23640 · Cited by 10
Yan, H., Zhao, L., Wang, J., Lin, L., Wang, H., Wang, C., Yu, Y., Lu, M., & Xu, T. (2023) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2023.06.056 · Cited by 10
BIOABSORBABLE FIXATION OF SCAPHOID FRACTURES AND NON-UNIONS; ANALYSIS OF EARLY CLINICAL OUTCOMES
Ya’ish, F., Bailey, C., Kelly, C. P., & Craigen, M. A. C. (2013) · Hand Surgery · doi:10.1142/s0218810413500378 · Cited by 12
Periprosthetic Femoral Fracture Due to Biodegradable Cement Restrictor
Dhawan, R., Mangham, D. C., & Graham, N. (2012) · The Journal of Arthroplasty · doi:10.1016/j.arth.2012.02.013 · Cited by 9
Lewandrowski, K., Bondre, S., Shea, M., Untch, C. M., Hayes, W. C., Hile, D. D., Wise, D. L., & Trantolo, D. J. (2002) · PubMed · Cited by 15
Alternative Materials for Fracture Fixation
Leong, K. W. (1995) · Connective Tissue Research · doi:10.3109/03008209509116838 · Cited by 9
Use of Bioabsorbable Pins in Surgical Fixation of Comminuted Periarticular Fractures
Bassuener, S. R., Mullis, B., Harrison, R. K., & SANDERS, R. W. (2012) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0b013e318247c754 · Cited by 8
Böstman, O. M., & Päivärinta, U. (1994) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100120313 · Cited by 8
Self-citationProtein Interactions with Polylactide-Polyglycolide Particles and Scaffolds
Schmitz, J. P., Zardeneta, G., Agrawal, C. M., Lee, T., Athanasiou, K. A., & Milam, S. B. (1997) · Tissue Engineering · doi:10.1089/ten.1997.3.257 · Cited by 8
Leroux, T. S., Perez‐Ordoñez, B., & von Schroeder, H. P. (2007) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2007.01.005 · Cited by 7
Les matériels d'ostéosynthèse résorbables
Iera, D., Haddad, A. J., Sándor, G. K. B., & Ashmmakhi, N. (2005) · Annales de Chirurgie Plastique Esthétique · doi:10.1016/j.anplas.2005.04.006 · Cited by 9
Song, J. H., Kang, C., Park, W. H., Lee, G.-S., Lee, J. K., Kim, D. H., & Lee, S. W. (2021) · The Journal of Foot & Ankle Surgery · doi:10.1053/j.jfas.2021.01.010 · Cited by 6
Lin, Y. S., Feng, C., Ye, S. B., Lin, Y. J., Chen, C. F., Liao, C. J., Chang, K., & Tsay, R.-Y. (2001) · Journal of Medical and Biological Engineering · Cited by 6
Biocompatibility of solid poly (ortho ester)
Ekholm, M., Salo, A., Syrjänen, S., Laine, P. O., Lindqvist, C. M., Kellomäki, M., VIRTANEN, I., & Suuronen, R. (1997) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1018552010027 · Cited by 6
Osteolytic Reaction to Polylevolactic Acid Fracture Fixation
Rovinsky, D., Nissen, T. P., & Otsuka, N. Y. (2001) · Orthopedics · doi:10.3928/0147-7447-20010201-22 · Cited by 6
Bioresorbable Materials for Bone Fixation: Review of Biological Concepts and Mechanical Aspects
Suuronen, R., & Lindqvist, C. (2007) · Springer eBooks · doi:10.1007/978-0-387-22427-5_13 · Cited by 6
Biofunctionality and immunocompatibility of starch-based biomaterials
Marques, A. M. P. (2004) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · Cited by 7
Xenogenic Tissues and Biomaterials for the Skeletal System
Zeugolis, D. I., Keeney, M., Collin, E. C., Fontana, G., & Pandit, A. S. (2011) · Elsevier eBooks · doi:10.1016/b978-0-08-055294-1.00079-9 · Cited by 8
Bioabsorbable behaviour of magnesium alloys – an in vivo approach
Ďurišin, M. (2015) · Elsevier eBooks · doi:10.1016/b978-1-78242-077-4.00004-8 · Cited by 5
Tendon and Ligament Fixation to Bone
Hill, C. M., An, Y. H., & Young, F. A. (2006) · Humana Press eBooks · doi:10.1385/1-59259-942-7:257 · Cited by 5
Lewandrowski, K., Bondre, S., Shea, M., Untch, C. M., Hayes, W. C., Hile, D. D., Wise, D. L., & Trantolo, D. J. (2002) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856202320892984 · Cited by 6
Tissue Engineering for Cardiac Regeneration
Gaetani, R., Doevendans, P. A., Messina, E., & Sluijter, J. P. G. (2011) · Studies in mechanobiology, tissue engineering and biomaterials · doi:10.1007/8415_2011_82 · Cited by 5
Casillas, M. M. (2006) · Techniques in Foot & Ankle Surgery · doi:10.1097/00132587-200603000-00007 · Cited by 5
Bioresorbable Materials for Bone Fixation: Review of Biological Concepts and Mechanical Aspects
Seppänen‐Kaijansinkko, R., & Lindqvist, C. (2019) · Springer eBooks · doi:10.1007/978-1-4939-1529-3_12 · Cited by 5
Wright, D. (2008) · CRC Press eBooks · doi:10.1081/e-ebbe2-120013912 · Cited by 4
Parsons, E. M., Yu, J. S., Pedroza, A. D., & Kaeding, C. C. (2013) · The Knee · doi:10.1016/j.knee.2013.03.001 · Cited by 3
Diaphyseal fractures treated by polylactide and hydroxyapatite pins. Experimental study in rat
Griffet, J., Chevallier, A., Hayek, T. E., Odin, G., Pebeyre, B., & Accorsi, E. (1999) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1008975014015 · Cited by 3
Sinisaari, I., Pätiälä, H., Böstman, O. M., Mäkelä, E. A., Partio, E. K., Hirvensalo, E., Rokkanen, P., & Törmälä, P. (1997) · Journal of Orthopaedic Science · doi:10.1007/bf02489518 · Cited by 3
Self-citation2.21 Xenogenic Tissues and Biomaterials for the Skeletal System ☆
Graceffa, V., Wu, Z., Gaspar, D., Spanoudes, K., Isa, I. L. M., Biggs, M. J. P., Mullen, A. M., Pandit, A. S., & Zeugolis, D. I. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.10204-8 · Cited by 2
Bajwa, N., Singh, P. A., Jyoti, K., Baldi, A., Chandra, R., & Madan, J. (2021) · BENTHAM SCIENCE PUBLISHERS eBooks · doi:10.2174/9781681088235121010010 · Cited by 3
Griffet, J., Accorsi, E., Chevallier, A., Hayek, T. E., Odin, G., & Meouchy, W. (2002) · European Journal of Orthopaedic Surgery & Traumatology · doi:10.1007/s00590-002-0031-8 · Cited by 2
Bone Implants: Processing, Embedding, Cutting, and Histopathology
Troiano, N. W., & Kacena, M. A. (2006) · Journal of Histotechnology · doi:10.1179/his.2006.29.4.253 · Cited by 2
BOP: Biocompatible osteoconductive polymer: An experimental approach
Buron, F., Bourgois, R., Burny, F., Chaboteaux, C., d'Hemricourt, J., Banna, S. E., Pasteels, J. L., Sintzoff, S., & Vienne, A. R. (1994) · Clinical Materials · doi:10.1016/0267-6605(94)90120-1 · Cited by 2
Eine klinische Klassifikation über Fremdkörperreaktionen auf biodegradierbare Implantate
Hoffmann, R. F. G., Weiler, A., Helling, H. J., & Rehm, K. E. (1998) · Hefte zur Zeitschrift Der Unfallchirurg · doi:10.1007/978-3-642-80390-1_30 · Cited by 5
Malek, M., & Obwegeser, J. A. (2003) · Journal of Biomaterials Applications · doi:10.1177/0885328203018001004 · Cited by 2
Gatzka, C., Helling, H. J., Prokop, A., Fischbach, R., & Rehm, K. E. (1997) · Hefte zur Zeitschrift Der Unfallchirurg · doi:10.1007/978-3-642-60913-8_278 · Cited by 3
Wright, D. D. (2015) · Taylor & Francis eBooks · doi:10.1081/e-ebpp-120013912 · Cited by 2
Fernández‐Costa, J. M., Fernández‐Garibay, X., Ramón‐Azcón, J., & Tejedera‐Villafranca, A. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-91821-3.00018-9 · Cited by 1
Inflammatory Response to Polymeric Materials
Labarre, D., & Carreno, M. (2002) · Springer eBooks · doi:10.1007/0-306-47583-9_25 · Cited by 1
Hutmacher, D. W., & Lam, C. X. F. (2008) · Elsevier eBooks · doi:10.1533/9781845695033.5.319 · Cited by 4
Arthroscopic Management of Shoulder Instability: Bio-Anchor (Linvatec)
Barber, F. A. (2001) · Springer eBooks · doi:10.1007/978-0-387-21541-9_9 · Cited by 1
Αbsorbable Plates for Isolated Ulnar Diaphyseal Fractures in Adults - A Case Series Study.
Kapoutsis, D., Kitridis, D., Sachinis, N. P., Ploumis, A., & Givissis, P. (2020) · PubMed Central · doi:10.13107/jocr.2020.v10.i04.1798 · Cited by 1
Poly(α-hydroxy acids): carriers for bone morphogenetic proteins
HOLLINGER, J., & Leong, K. W. (1996) · Elsevier eBooks · doi:10.1016/b978-008045154-1.50018-6 · Cited by 2
In vitro and in vivo analyses of the biocompatibility of sintered TCP-HA composite screws
Sun, Y.-G., Lim, M.-S., Kim, Y., & Choi, J.-I. (2022) · Oral Biology Research · doi:10.21851/obr.46.04.202212.171 · Cited by 1
Use of an Allograft Bone Button for Rotator Cuff Repair
Bonutti, P. M., Cremens, M. J., Lee, F. S., & Gray, T. J. (2002) · Orthopedics · doi:10.3928/0147-7447-20020201-18 · Cited by 1
Bioabsorbable implants in knee surgery : An experimental and clinical study
Tuompo, P. (2004) · Helda - University of Helsinki Institutional Repository · Cited by 1
Weiler, A., Helling, H. J., Kirch, U., & Rehm, K. E. (1998) · Hefte zur Zeitschrift Der Unfallchirurg · doi:10.1007/978-3-642-80390-1_18 · Cited by 3
Sinisaari, I. (2004) · Helda - University of Helsinki Institutional Repository · Cited by 2
Arthroskopische Stabilisierung mit Ankern
Roscher, E., Imhoff, A. B., Hausberger, K., Sperner, G., Öttl, G. M., König, U., Lattig, C. F., Imhoff, A. B., & Hoffmann, F. (1999) · Steinkopff eBooks · doi:10.1007/978-3-642-58711-5_6 · Cited by 1
Materiali utilizzati per l’osteosintesi
Meyrueis, J.-P., Meyrueis, J.-P., & Sohier-Meyrueis, A. N. N. E. (2005) · EMC - Techniche Chirurgiche - Chirurgica Ortopedica · doi:10.1016/s2211-0801(05)70067-4
Bioabsorbable materials for osteosynthesis and small joint arthroplasty in the hand
Waris, E. (2008) · Helda - University of Helsinki Institutional Repository · Cited by 1
Resorbable Materials in Orthopedic Surgery
Borden, M. D. (2006) · Wiley eBooks · doi:10.1002/9780471740360.ebs0121
Choi, C.-H., Kim, S.-K., & Han, B.-R. (2008) · Clinics in Shoulder and Elbow · doi:10.5397/cise.2008.11.2.158
Stábile, G. A. V. (2007) · doi:10.47749/t/unicamp.2007.408762 · Cited by 1
for Osteosynthesis and Small Joint Arthroplasty in the Hand
Waris, E. (2008)
Nagata, M., Hoshi, N., Yoshinaka, H., Shiomi, H., Takenaka, M., Masuda, A., Maruyama, Y., Uchida, R., Azuma, T., & Kutsumi, H. (2016) · Progress in Biomaterials · doi:10.1007/s40204-016-0050-x
Management of Osteoporotic Fractures of Lower Extremities
Palczewski, D. (2002) · CRC Press eBooks · doi:10.1201/b14228-20
Anderson, J. C., & Paulos, L. E. (2008) · Elsevier eBooks · doi:10.1016/b978-1-4160-3834-4.10037-x
Claes, L., Ignatius, A. A., Rehm, K. E., & Scholz, C. (1998) · Hefte zur Zeitschrift Der Unfallchirurg · doi:10.1007/978-3-642-80390-1_13
Results after Operative Treatment for Maisonneuve Fracture
Lee, J. Y., Ha, S.-H., Sohn, H. M., & Lee, K.-C. (2007) · Journal of Korean Foot and Ankle Society
Tissue Engineering of Skeletal Muscle
(2008) · CRC Press eBooks · doi:10.1081/e-ebbe2-120005550
Tendon and muscle responses to biomaterials
Wang, W., Koh, B. T. H., & Steffi, C. (2020) · Elsevier eBooks · doi:10.1016/b978-0-08-102967-1.00028-1
(2000) · Springer eBooks · doi:10.1007/0-387-21854-8_4
Borden, M. D. (2006) · Wiley eBooks · doi:10.1002/0471732877.emd021 · Cited by 1
HARDWARE BREAKAGE AND IMPLANT FAILURE IN THE FOOT AND ANKLE
Miller, S. D. (1998) · Foot and Ankle Clinics · doi:10.1016/s1083-7515(24)00015-9
Konstantas, O., Roustemis, A. G., Koulalis, D., & Mastrokalos, D. S. (2025) · Journal of Long-Term Effects of Medical Implants · doi:10.1615/jlongtermeffmedimplants.2025062524
Metadata
- Authors
- BÖSTMAN, O. M.
- Affiliations
- Helsinki University Hospital (FI)
- Corresponding author
- BÖSTMAN, O. M.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1992-05
- Volume
- 278
- Issue
- 278
- Pages
- 193???199
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2310493614
- Semantic Scholar
- a558e4523ac81881f0d1fd695bba78b80282957d
- Cited by
- 185
- References
- 0
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 1 · 2022: 3 · 2021: 3 · 2020: 3 · 2019: 3 · 2018: 1 · 2017: 3 · 2016: 4 · 2015: 6 · 2014: 4 · 2013: 5 · 2012: 5
- FWCI
- 4.45
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Orthopaedics and Related Research (publishedVersion)
- PubMed (publishedVersion)
- PubMed
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Foot and Ankle Surgery
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- polyglycolic acid, absorbable implants, ankle fractures, foreign body reaction, granulomatous inflammation, sinus tract, osteolysis, open reduction and internal fixation, bimalleolar fractures, surgical drainage
- MeSH terms
- Drainage, Foreign-Body Reaction, Humans, Polyglycolic Acid, Radiography, Reoperation, Ankle Injuries, Prostheses and Implants, Fractures, Bone
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.