Intense Granulomatous Inflammatory Lesions Associated With Absorbable Internal Fixation Devices Made of Polyglycolide in Ankle Fractures
The DOI matches its Crossref record.
Abstract
Since absorbable internal fracture fixation devices made of polyglycolide have been increasingly used clinically, a peculiar type of complication has emerged. After an initially uneventful course, a local nonbacterial inflammatory reaction appears two to four months after the operation, resulting in a copiously discharging sinus on the skin. A series of 286 patients with unimalleolar or bimalleolar fractures were treated by open reduction and internal fixation using cylindrical rods made of polyglycolide. Among these there occurred 18 nonbacterial inflammatory tissue responses (6.3% of the total) requiring surgical drainage. Six patients had an intense reaction necessitating repeated surgical measures and inpatient management. The hospital stay of these patients averaged 18 days. The mean duration of the discharge from the lesions was 10.8 weeks. Microscopic examination of biopsy specimens showed a nonspecific foreign-body reaction composed mainly of neutrophilic polymorphonuclear leukocytes and foreign-body giant cells phagocytizing the polymer debris left behind by the decomposing implants. On roentgenograms, osteolytic increase of the diameter of the implant channels was observed, but the bony union of the fracture seemed not to be disturbed. Thus the factors increasing the susceptibility of some individuals to this complication remain unknown.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In clinical studies where PGA was used as fracture fixation, foreign-body responses or osteolytic reactions have been reported”
From Biodegradable synthetic polymers for tissue engineering (2003) · cites this paper as Böstman, 1992
Citations
Cites
Still being checked.
Cited by
Biodegradation and biocompatibility of PLA and PLGA microspheres
Anderson, J. M., & Shive, M. S. (1997) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(97)00048-3 · Cited by 2,617
Biodegradable synthetic polymers for tissue engineering
CSIRO Molecular Science, B. 1., & Gunatillake, P. (2003) · European Cells and Materials · doi:10.22203/ecm.v005a01 · Cited by 1,765
Athanasiou, K. A., Niederauer, G. G., & Agrawal, C. M. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85754-1 · Cited by 1,497
Biodegradation and biocompatibility of PLA and PLGA microspheres
Anderson, J. M., & Shive, M. S. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.004 · Cited by 814
Biodegradable Materials for Bone Repair and Tissue Engineering Applications
Sheikh, Z., Najeeb, S., Khurshid, Z., Verma, V., Rashid, H., & Glogauer, M. (2015) · Materials · doi:10.3390/ma8095273 · Cited by 782
Host response to tissue engineered devices
Babensee, J. E., Anderson, J. M., McIntire, L. V., & Mikos, A. G. (1998) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(98)00023-4 · Cited by 585
Clinical biocompatibility of biodegradable orthopaedic implants for internal fixation: a review
Böstman, O., & Pihlajamäki, H. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00129-0 · Cited by 509
Self-citationAdverse Tissue Reactions to Bioabsorbable Fixation Devices
B??stman, O. M., & Pihlajam??ki, H. K. (2000) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200002000-00026 · Cited by 476
Self-citationLam, C. X. F., Savalani, M. M., Teoh, S.-H., & Hutmacher, D. W. (2008) · Biomedical Materials · doi:10.1088/1748-6041/3/3/034108 · Cited by 444
Recent developments in biodegradable synthetic polymers
Gunatillake, P., Mayadunne, R., & Adhikari, R. (2006) · Biotechnology Annual Review · doi:10.1016/s1387-2656(06)12009-8 · Cited by 444
Graft Fixation in Cruciate Ligament Reconstruction
Brand, J., Weiler, A., Caborn, D. N. M., Brown, C. H., & Johnson, D. L. (2000) · The American Journal of Sports Medicine · doi:10.1177/03635465000280052501 · Cited by 436
Michelson, J. D. (1995) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199501000-00020 · Cited by 275
Biodegradable Implants in Sports Medicine: The Biological Base
Weiler, A., Hoffmann, R. F. G., Stähelin, A. C., Helling, H.-J., & Südkamp, N. P. (2000) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/s0749-8063(00)90055-0 · Cited by 236
Bone Formation with Use of rhBMP-2 (Recombinant Human Bone Morphogenetic Protein-2)*
ZEGZULA, H. D., BUCK, D. C., BREKKE, J., WOZNEY, J. M., & HOLLINGER, J. O. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199712000-00003 · Cited by 239
Surface Chemistry of Biodegradable Polymers for Drug Delivery Systems
Ha, C.-S., & Gardella, J. A. (2005) · Chemical Reviews · doi:10.1021/cr040419y · Cited by 229
Polyglycolic Acid-Induced Inflammation: Role of Hydrolysis and Resulting Complement Activation
Ceonzo, K., Gaynor, A., Shaffer, L., Kojima, K., Vacanti, C. A., & Stahl, G. L. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.301 · Cited by 209
Degradation Behaviors of Electrospun Resorbable Polyester Nanofibers
Dong, Y., Liao, S., Ngiam, M., Chan, C. K., & Ramakrishna, S. (2009) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2008.0619 · Cited by 200
Poly(α-hydroxy acids): carriers for bone morphogenetic proteins
Hollinger, J. O., & Leong, K. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85763-2 · Cited by 203
Weiler, A., Windhagen, H. J., Raschke, M. J., Laumeyer, A., & Hoffmann, R. F. G. (1998) · The American Journal of Sports Medicine · doi:10.1177/03635465980260010401 · Cited by 196
Preliminary results of an absorbable interference screw
Barber, F. A., Elrod, B. F., McGuire, D. A., & Paulos, L. E. (1995) · Arthroscopy · doi:10.1016/0749-8063(95)90129-9 · Cited by 178
Absorbable polyglycolide devices in trauma and bone surgery
Ashammakhi, N., & Rokkanen, P. (1997) · Biomaterials · doi:10.1016/s0142-9612(96)00107-x · Cited by 166
Weiler, A., Helling, H. J., Kirch, U., Zirbes, T. K., & Rehm, K. E. (1996) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.78b3.0780369 · Cited by 187
Böstman, O. M. (1998) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.80b2.0800333 · Cited by 159
Self-citationWilliams, D. F. (2017) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.6b00607 · Cited by 134
Thordarson, D. B., Samuelson, M. A., Shepherd, L. E., Merkle, P. F., & Lee, J. (2001) · Foot & Ankle International · doi:10.1177/107110070102200411 · Cited by 134
Myocardial tissue engineering: the extracellular matrix☆
Akhyari, P., Kamiya, H., Haverich, A., Karck, M., & Lichtenberg, A. (2008) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2008.03.062 · Cited by 127
Ashammakhi, N. A., Peltoniemi, H. H., Waris, E., Suuronen, R., Serlo, W. S., Kellomäki, M., Törmälä, P., & Waris, T. H. (2001) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-200107000-00027 · Cited by 135
Foreign‐Body Reaction to the Bioabsorbable Suretac Device
Burkart, A., Imhoff, A. B., & Roscher, E. (2000) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/s0749-8063(00)90134-8 · Cited by 125
Claes, L. E., Ignatius, A. A., Rehm, K. E., & Scholz, C. (1996) · Biomaterials · doi:10.1016/0142-9612(95)00327-4 · Cited by 123
Adverse reactions to an absorbable shoulder fixation device
Edwards, D. J., Hoy, G., Saies, A. D., & Hayes, M. G. (1994) · Journal of Shoulder and Elbow Surgery · doi:10.1016/s1058-2746(09)80040-2 · Cited by 124
Biostability and biological performance of a PDMS-based polyurethane for controlled drug release
Simmons, A., Padsalgikar, A., Ferris, L. M., & Poole-Warren, L. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.007 · Cited by 119
Polymers, Drug Release, and Drug‐Eluting Stents
COMMANDEUR, S., VAN BEUSEKOM, H. M. M., & VAN DER GIESSEN, W. J. (2006) · Journal of Interventional Cardiology · doi:10.1111/j.1540-8183.2006.00198.x · Cited by 118
Bioresorbable Plates and Screws for Clinical Applications: A Review
Pina, S., & Ferreira, J. M. F. (2012) · Journal of Healthcare Engineering · doi:10.1260/2040-2295.3.2.243 · Cited by 119
Athanasiou, K. A., Schmitz, J. P., & Agrawal, C. M. (1998) · Tissue Engineering · doi:10.1089/ten.1998.4.53 · Cited by 110
Erdmann, N., Bondarenko, O. O., Hewicker‐Trautwein, M., Angrisani, N., Reifenrath, J., Lucas, A., & Meyer‐Lindenberg, A. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-63 · Cited by 108
Larsen, M. W., Pietrzak, W. S., & DeLee, J. C. (2005) · The American Journal of Sports Medicine · doi:10.1177/0363546504265927 · Cited by 112
Metallic or Absorbable Fracture Fixation Devices: A Cost Minimization Analysis
B�stman, O. (1996) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199608000-00029 · Cited by 103
Self-citationPoly(α-hydroxy acid) based polymers: A review on material and degradation aspects
Ginjupalli, K., Shavi, G. V., Averineni, R. K., Bhat, M., Udupa, N., & Upadhya, N. P. (2017) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2017.08.024 · Cited by 105
Complications of open reduction and internal fixation of ankle fractures
Leyes, M., Torres, R., & Guillén, P. (2003) · Foot and Ankle Clinics · doi:10.1016/s1083-7515(02)00162-6 · Cited by 98
The history of suture anchors in orthopaedic surgery
Visscher, L. E., Jeffery, C., Gilmour, T., Anderson, L., & Couzens, G. B. (2018) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2018.11.008 · Cited by 97
Bioresorbable implants — practical considerations
Pietrzak, W. S., Sarver, D. R., & Verstynen, M. L. (1996) · Bone · doi:10.1016/s8756-3282(96)00139-1 · Cited by 114
Shi, Z., Zheng, F., Zhou, Z., Li, M., Fan, Z., Ye, H., Zhang, S., Xiao, T., Chen, L., Tao, T. H., et al. (2019) · Advanced Science · doi:10.1002/advs.201801617 · Cited by 94
Devices for Dentoalveolar Regeneration: An Up‐To‐Date Literature Review
Hardwick, R., Hayes, B. K., & Flynn, C. (1995) · Journal of Periodontology · doi:10.1902/jop.1995.66.6.495 · Cited by 94
Effect of RGD coating on osteocompatibility of PLGA-polymer disks in a rat tibial wound
Eid, K., Chen, E., Griffith, L., & Glowacki, J. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200111)57:2<224::aid-jbm1162>3.0.co;2-f · Cited by 90
Bach, F., Carlier, R., Elis, J. B., Mompoint, D. M., Feydy, A., Judet, O., Beaufils, P., & Vallée, C. A. (2002) · Radiology · doi:10.1148/radiol.2252010357 · Cited by 86
Barber, F. A., & Herbert, M. A. (1999) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/s0749-8063(99)70003-4 · Cited by 82
Tomblyn, S., Pettit Kneller, E. L., Walker, S. J., Ellenburg, M. D., Kowalczewski, C. J., Van Dyke, M., Burnett, L., & Saul, J. M. (2016) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.33438 · Cited by 78
Marti, C. B., Imhoff, A. B., Bahrs, C., & Roméro, J. (1997) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s001670050053 · Cited by 80
Tangpasuthadol, V., Pendharkar, S. M., Peterson, R. C., & Kohn, J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00105-8 · Cited by 91
Biodegradable fixation of mandibular fractures in children: Stability and early results
Yerit, K. C., Hainich, S., Enislidis, G., Turhani, D., Klug, C., Wittwer, G., Oeckher, M., Undt, G., Kermer, C., Watzinger, F., et al. (2005) · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · doi:10.1016/j.tripleo.2004.11.013 · Cited by 87
Al‐Sukhun, J., & Lindqvist, C. (2006) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2006.03.010 · Cited by 71
Outcome after surgery for Maisonneuve fracture of the fibula
Sproule, J. A., Khalid, M., O’Sullivan, M. E., & McCabe, J. P. (2003) · Injury · doi:10.1016/s0020-1383(03)00155-4 · Cited by 74
Weber, N., Bolikal, D., Bourke, S. L., & Kohn, J. (2004) · Journal of Biomedical Materials Research. Part A · doi:10.1002/jbm.a.20086 · Cited by 69
Al‐Sukhun, J., Törnwall, J., Lindqvist, C., & Kontio, R. K. (2005) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2005.09.013 · Cited by 66
Ylikontiola, L. P., Sundqvuist, K., Sándor, G. K. B., Törmälä, P., & Ashammakhi, N. A. (2004) · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · doi:10.1016/j.tripleo.2003.10.030 · Cited by 65
Comparison of costs in ankle fractures treated with absorbable or metallic fixation devices
Juutilainen, T., P�ti�l�, H., Ruuskanen, M. M., & Rokkanen, P. (1997) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/bf00393710 · Cited by 62
Delayed Foreign-body Reaction to Absorbable Implants in Metacarpal Fracture Treatment
Givissis, P., Stavridis, S. I., Papagelopoulos, P. J., Antonarakos, P. D., & Christodoulou, A. G. (2010) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-010-1388-3 · Cited by 65
Fractures of the Lower Extremity
Whittle, A. P. (2008) · Elsevier eBooks · doi:10.1016/b978-0-323-03329-9.50054-4 · Cited by 64
Bhattacharya, K., Bag, A. K., Tripathi, R. P., Samanta, S. K., Pal, B. C., Shaha, C., & Mandal, C. (2014) · Europe PMC (PubMed Central) · Cited by 66
Spotlight on Naturally Absorbable Osteofixation Devices
Ashammakhi, N. A., Suuronen, R., Tiainen, J., Törmälä, P. O., & Waris, T. H. (2003) · Journal of Craniofacial Surgery · doi:10.1097/00001665-200303000-00021 · Cited by 63
Ashammakhi, N. A., Rénier, D., Arnaud, É., Marchac, D., Ninkovic, M. M., Donaway, D., Jones, B. M., Serlo, W. S., Laurikainen, K., Törmälä, P., et al. (2004) · Journal of Craniofacial Surgery · doi:10.1097/00001665-200407000-00031 · Cited by 62
Complications of Absorbable Fixation in Maxillofacial Surgery: A Meta-Analysis
Yang, L., Xu, M., Jin, X., Xu, J., Lu, J., Zhang, C., Tian, T., & Teng, L. (2013) · PLoS ONE · doi:10.1371/journal.pone.0067449 · Cited by 57
Biomechanical Evaluation of Polylactide Absorbable Screws Used for Syndesmosis Injury Repair
Thordarson, D. B., Hedman, T. P., Gross, D., & Magre, G. R. (1997) · Foot & Ankle International · doi:10.1177/107110079701801004 · Cited by 57
Lee, J.-W., & Gardella, J. A. J. (2001) · Macromolecules · doi:10.1021/ma0022351 · Cited by 58
In vivo comparison of a metal versus a biodegradable suture anchor 1
DeJong, L. E. S., DeBerardino, L. T. M., Brooks, D. E., & Judson, K. (2004) · Arthroscopy · doi:10.1016/j.arthro.2004.03.008 · Cited by 53
Gonzalez-Lomas, G. P., Cassilly, R. T., Remotti, F., & Levine, W. N. (2010) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-010-1580-5 · Cited by 52
Local foreign-body reactions to biodegradable implants
Hoffmann, R. F. G., Weiler, A., Helling, H. J., Krettek, C., & Rehm, K. E. (1997) · Der Unfallchirurg · doi:10.1007/s001130050172 · Cited by 71
Flipped patellar tendon autograft anterior cruciate ligament reconstruction
Barber, F. A. (2000) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1053/jars.2000.4384 · Cited by 51
Verheyen, C. C. P. M., De Wijn, J. R., van Blitterswijk, C. A., Rozing, P. M., & de Groot, K. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270817 · Cited by 50
Peltoniemi, H. H., Tulamo, R., Toivonen, T. S., Hallikainen, D., Törmälä, P., & Waris, T. H. (1999) · Journal of neurosurgery · doi:10.3171/jns.1999.90.5.0910 · Cited by 51
Bioscrew fixation of patellar tendon autografts
Barber, F. A., Elrod, B. F., McGuire, D. A., & Paulos, L. E. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00130-7 · Cited by 53
Hunt, J. A., & Callaghan, J. T. (2008) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-008-0528-8 · Cited by 48
Caminear, D. S., Pavlovich, R., & Pietrzak, W. S. (2005) · The Journal of Foot & Ankle Surgery · doi:10.1053/j.jfas.2005.02.003 · Cited by 46
Barber, F. A. (1999) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/s0749-8063(99)70052-6 · Cited by 52
Krishnamurithy, G., Murali, M. R., Hamdi, M., Abbas, A. A., Raghavendran, H. R. B., & Kamarul, T. (2013) · Ceramics International · doi:10.1016/j.ceramint.2013.06.067 · Cited by 48
Marques, A. P., Reis, R. L., & Hunt, J. A. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30155 · Cited by 46
Gómez, G., Korkiakoski, S., González, M.-M., Länsman, S., Ellä, V., Salo, T. A., Kellomäki, M., Ashammakhi, N. A., & Arnaud, É. (2006) · Journal of Craniofacial Surgery · doi:10.1097/01.scs.0000231624.87640.55 · Cited by 41
Absorbable Biologically Based Internal Fixation
Ibrahim, A. M. S., Koolen, P. G. L., Kim, K., Perrone, G. S., Kaplan, D. L., & Lin, S. J. (2014) · Clinics in Podiatric Medicine and Surgery · doi:10.1016/j.cpm.2014.09.009 · Cited by 43
Böstman, O. M. (1994) · Scandinavian Journal of Social Medicine · doi:10.1177/140349489402200107 · Cited by 39
Self-citationPark, H. B., Keyurapan, E., Gill, H. S., Selhi, H. S., & McFarland, E. G. (2006) · The American Journal of Sports Medicine · doi:10.1177/0363546505284240 · Cited by 38
Tissue Engineering Skeletal Muscle
Kosnik, P. E., Dennis, R. G., & Vandenburgh, H. H. (2003) · Springer eBooks · doi:10.1007/0-387-21547-6_28 · Cited by 40
Monteiro, G. C., Ejnisman, B., Andreoli, C. V., Pochini, A. C., & Cohen, M. (2008) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2007.12.013 · Cited by 36
Wildemann, B., Sander, A., Schwabe, P., Lucke, M., Stöckle, U., Raschke, M. J., Haas, N., & Schmidmaier, G. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.10.004 · Cited by 46
The in vivo histology of an absorbable suture anchor: a preliminary report
Barber, F. A., & Deck, M. A. (1995) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/0749-8063(95)90092-6 · Cited by 41
Buijs, G. J., Stegenga, B., & Bos, R. R. M. (2006) · Journal of Dental Research · doi:10.1177/154405910608501102 · Cited by 40
Biodegradable metallic suture anchors: A review
Nouri, A., Shirvan, A. R., Li, Y., & Wen, C. (2022) · Smart Materials in Manufacturing · doi:10.1016/j.smmf.2022.100005 · Cited by 45
Fractures of the Lower Extremity
Rudloff, M. I. (2013) · Elsevier eBooks · doi:10.1016/b978-0-323-07243-4.00054-2 · Cited by 42
Buelow, J.-U., Siebold, R., & Ellermann, A. (2000) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s001670000120 · Cited by 34
Winet, H., Hollinger, J. O., & Stevanovic, M. (1995) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100130507 · Cited by 31
Poly‐D,L‐Lactide Interference Screws for Anterior Cruciate Ligament Reconstruction
Barber, F. A. (2005) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2005.04.104 · Cited by 30
Palmieri, A., Zollino, I., Clauser, L. C., Lucchese, A., Girardi, A., Farinella, F., & Carinci, F. (2011) · Journal of Craniofacial Surgery · doi:10.1097/scs.0b013e31820f7d34 · Cited by 29
PIHLAJAMÄKI, H. K., Böstman, O. M., & Rokkanen, P. (1994) · International Orthopaedics · doi:10.1007/bf02484413 · Cited by 28
Self-citationBiomedical Applications of Polyhydroxyalkanoates
Lizarraga‐Valderrama, L. R., Panchal, B., Thomas, C., Boccaccini, A. R., & Roy, I. (2016) · Wiley eBooks · doi:10.1002/9781119126218.ch20 · Cited by 30
Böstman, O. M., Viljanen, J., Salminen, S., & PIHLAJAMÄKI, H. K. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00123-x · Cited by 29
Self-citationPapalia, R., Franceschi, F., Balzani, L. A. D., D’Adamio, S., Denaro, V., & Maffulli, N. (2014) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2014.03.030 · Cited by 25
Early Experience with Biodegradable Implants in Pediatric Patients
Mavrogenis, A. F., Kanellopoulos, A. D., Nomikos, G. N., Papagelopoulos, P. J., & Soucacos, P. N. (2008) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-008-0537-4 · Cited by 25
Varga, M., Józsa, G., Hanna, D., Tóth, M., Hajnal, B., Krupa, Z., & Kassai, T. (2022) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-022-05305-w · Cited by 24
Biodegradable internal fixation
Strycker, M. L. (1995) · The Journal of Foot & Ankle Surgery · doi:10.1016/s1067-2516(09)80107-5 · Cited by 25
Biomechanical Failure of Metacarpal Fracture Resorbable Plate Fixation
Lionelli, G. T., & Korentager, R. A. (2002) · Annals of Plastic Surgery · doi:10.1097/00000637-200208000-00015 · Cited by 23
Weber, C., Eifler, R., Seitz, J., Maier, H. J., Reifenrath, J., Lenarz, T., & Ďurišin, M. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.03.003 · Cited by 23
Metadata
- Authors
- BÖSTMAN, O. M.
- Affiliations
- Helsinki University Hospital (FI)
- Corresponding author
- BÖSTMAN, O. M.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1992-05
- Volume
- 278
- Issue
- 278
- Pages
- 193???199
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2310493614
- Semantic Scholar
- a558e4523ac81881f0d1fd695bba78b80282957d
- Cited by
- 185
- References
- 0
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 1 · 2022: 3 · 2021: 3 · 2020: 3 · 2019: 3 · 2018: 1 · 2017: 3 · 2016: 4 · 2015: 6 · 2014: 4 · 2013: 5 · 2012: 5
- FWCI
- 4.45
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Orthopaedics and Related Research (publishedVersion)
- PubMed (publishedVersion)
- PubMed
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Foot and Ankle Surgery
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- polyglycolic acid, absorbable implants, ankle fractures, foreign body reaction, granulomatous inflammation, sinus tract, osteolysis, open reduction and internal fixation, bimalleolar fractures, surgical drainage
- MeSH terms
- Drainage, Foreign-Body Reaction, Humans, Polyglycolic Acid, Radiography, Reoperation, Ankle Injuries, Prostheses and Implants, Fractures, Bone
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.