Wear Patterns on Retrieved Polyethylene Tibial Inserts and Their Relationship to Technical Considerations During Total Knee Arthroplasty
The DOI matches its Crossref record.
Abstract
Fifty-five unconstrained polyethylene tibial inserts were retrieved at revision total knee arthroplasty and examined for evidence of wear after a mean implantation time of 34.2 months (2.5-80 months). Twenty inserts were ultra-high molecular weight polyethylene (UHMWPE) and 35 were carbon-reinforced polyethylene. Topographic maps of the articular and metal-backed surfaces of each component were constructed to characterize the extent and location of polyethylene degradation, identified visually by mode. In 32 of the retrieved inserts, pre- and postarthroplasty or prerevision radiographs were analyzed for component positioning, sizing, and extremity alignment. These factors then were compared with the patterns and severity of polyethylene wear on the inserts to establish correlations. Severe generalized articular wear was seen in inserts with third body wear from patellar metal-backed failure and cement debris. Severe localized delamination wear was seen in inserts with rotational-subluxation patterns of wear (p = 0.05). The external rotation subluxation wear pattern was strongly associated with knees that had lateral subluxation of the patella (p = 0.0002). Articular wear and cold flow into screw holes tended to be greater in the tightest prearthroplasty compartment (medial in the varus knee [p = 0.0157]; lateral in the valgus knees [p = 0.0226]). Fourteen of 16 knees with a preoperative varus deformities--even when corrected to a normal postarthroplasty anatomic axis--still had greater medial compartment articular wear (p = 0.001). Twelve of these knees did not have a medial release at the time of initial arthroplasty. Preoperative varus also was found to be related to the occurrence of posteromedial cold flow of polyethylene into tibial tray screw holes (p = 0.007). Increasing tibial insert posterior slope was associated with increasingly posterior articular wear track location (p = 0.03). This study indicates that unconstrained tibial component wear patterns and severity may be associated with clinical and mechanical factors under the surgeon's control, including component size and position, and knee alignment and ligament balance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Meta-Analysis of Alignment Outcomes in Computer-Assisted Total Knee Arthroplasty Surgery
Mason, J. B., Fehring, T. K., Estok, R., Banel, D., & Fahrbach, K. (2007) · The Journal of Arthroplasty · doi:10.1016/j.arth.2007.08.001 · Cited by 548
Song, E.-K., Seon, J.-K., Yim, J.-H., Netravali, N. A., & Bargar, W. L. (2013) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-012-2407-3 · Cited by 447
Current Concepts Review - Wear in Total Hip and Knee Replacements*
SCHMALZRIED, T. P., & CALLAGHAN, J. J. (1999) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199901000-00016 · Cited by 395
Good Alignment After Total Knee Arthroplasty Leads to Faster Rehabilitation and Better Function
Longstaff, L. M., Sloan, K., Stamp, N., Scaddan, M., & Beaver, R. (2009) · The Journal of Arthroplasty · doi:10.1016/j.arth.2008.03.002 · Cited by 380
Osteolysis around total knee arthroplasty: A review of pathogenetic mechanisms
Gallo, J., Goodman, S. B., Konttinen, Y. T., Wimmer, M. A., & Holinka, M. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.05.005 · Cited by 353
Meta-Analysis of Navigation vs Conventional Total Knee Arthroplasty
Hetaimish, B. M., Khan, M. M., Simunovic, N., Al-Harbi, H. H., Bhandari, M., & Zalzal, P. K. (2012) · The Journal of Arthroplasty · doi:10.1016/j.arth.2011.12.028 · Cited by 352
Computer Assisted Knee Replacement
Delp, S. L., Stulberg, D. S., Davies, B., Picard, F., & Leitner, F. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199809000-00007 · Cited by 336
THREE-DIMENSIONAL MECHANICS, KINEMATICS, AND MORPHOLOGY OF THE KNEE VIEWED IN VIRTUAL REALITY
ECKHOFF, D. G., BACH, J. M., SPITZER, V. M., REINIG, K. D., BAGUR, M. M., BALDINI, T. H., & FLANNERY, N. M. P. (2005) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200511002-00009 · Cited by 293
Surgical Techniques and Instrumentation in Total Knee Arthroplasty
Vail, T. P., Lang, J. E., & Van Sikes, C. (2012) · Insall & Scott Surgery of the Knee · doi:10.1016/b978-1-4377-1503-3.00105-0 · Cited by 230
van der List, J. P., Chawla, H., Joskowicz, L., & Pearle, A. D. (2016) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-016-4305-9 · Cited by 200
“1 3 wear patterns [129], instability [90] and decreased proprioception [5].”
BackgroundSpencer, J. M., Chauhan, S. K., Sloan, K., Taylor, A., & Beaver, R. J. (2007) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.89b4.18094 · Cited by 187
The cruciate ligaments in total knee arthroplasty
Stiehl, J. B., Komistek, R. D., Cloutier, J.-M., & Dennis, D. A. (2000) · The Journal of Arthroplasty · doi:10.1054/arth.2000.4638 · Cited by 182
Harris, M. L., Morberg, P., Bruce, W. J. M., & Walsh, W. R. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00072-x · Cited by 159
“(Collier et al., 1990; Kadoya et al., 1997; Wang et al., 1995; Wasielewski et al., 1994) Many factors contribute to wear and failure of UHMWPE including component geometry and loading conditions.”
Background
Metadata
- Authors
- WASIELEWSKI, R. C., GALANTE, J. O., LEIGHTY, R. M., NATARAJAN, R. N., & ROSENBERG, A. G.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1994-02
- Volume
- 299
- Issue
- 299
- Pages
- 31???43
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2073483220
- Cited by
- 563
- References
- 0
- FWCI
- 6.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.