Diurnal Variation of Corneal Sensitivity and Thickness
The DOI matches its Crossref record.
Abstract
PURPOSE: To measure the diurnal variation of central corneal sensitivity and thickness over 24 hours. METHODS: A noncontact pneumatic esthesiometer to measure central corneal sensitivity and an optical pachymeter to measure central corneal thickness were used on 20 noncontact lens wearers. These measurements were performed at 22:00 before 8 hours of sleep and on the following day on eye opening and at hourly intervals between 7:00 and 22:00. RESULTS: Central corneal sensitivity varied by 35% over the 24 hours. Sensitivity was significantly lower by 17.1 +/- 2.1% on eye opening and recovered to the level of the previous night after 4 hours. Corneal sensitivity continued to increase throughout the day but was not significantly higher. Central corneal thickness varied by 3.9% over the 24 hours. The mean overnight corneal swelling was 2.9 +/- 0.31%, and 2 hours after eye opening, the cornea had deswelled to the same thickness as the previous night. The cornea thinned further throughout the day, but there were no statistically significant differences between the values after 14:00. There was a high correlation between corneal sensitivity and thickness over time (r = 0.8; p < 0.05). DISCUSSION: Corneal sensitivity correlated with corneal thickness: both were higher on awakening and then decreased and remained below the levels measured the previous night. This may be due to physiological and/or environmental factors. The lack of significant differences between the values after 14:00 suggests that baseline may be measured at any time from 7 hours after eye opening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Central Corneal Thickness and Corneal Hysteresis Associated With Glaucoma Damage
Congdon, N. G., Broman, A. T., Bandeen-Roche, K., Grover, D., & Quigley, H. A. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2005.12.007 · Cited by 507
Peripheral Refraction in Myopic Patients After Orthokeratology
Queirós, A., González-Méijome, J. M., Jorge, J., Villa-Collar, C., & Gutiérrez, A. R. (2010) · Optometry and Vision Science · doi:10.1097/opx.0b013e3181d951f7 · Cited by 200
“and at least 2 h after lens removal to minimize the influence of treatment regression(27) and diurnal variations in corneal thickness that might potentially influence anterior corneal topography.(28,29)”
BackgroundDiurnal Variation of Corneal Shape and Thickness
Read, S. A., & Collins, M. J. (2009) · Optometry and Vision Science · doi:10.1097/opx.0b013e3181981b7e · Cited by 182
Determination of the Modulus of Elasticity of the Human Cornea
Elsheikh, A., Wang, D., & Pye, D. (2007) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20071001-11 · Cited by 179
Hubanova, R., Aptel, F., Chiquet, C., Mottet, B., & Romanet, J. (2014) · Acta Ophthalmologica · doi:10.1111/aos.12241 · Cited by 51
Metadata
- Authors
- du Toit, R., Vega, J. A., Fonn, D., & Simpson, T.
- Venue
- Cornea
- Published
- 2003-04
- Volume
- 22
- Issue
- 3
- Pages
- 205-209
- ISSN
- 0277-3740 (ISSN-L)
- OpenAlex
- W2025993200
- Cited by
- 197
- References
- 0
- FWCI
- 6.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diurnal Variation of Corneal Sensitivity and Thickness. https://app.cochat.ai/papers/10.1097/00003226-200304000-00004
- The paper
- du Toit, R., Vega, J. A., Fonn, D., & Simpson, T. (2003). Diurnal Variation of Corneal Sensitivity and Thickness. Cornea. https://doi.org/10.1097/00003226-200304000-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.