Diurnal Variation of Corneal Shape and Thickness
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
PURPOSE: To investigate associations between the diurnal variation in a range of corneal parameters, including anterior and posterior corneal topography, and regional corneal thickness. METHODS: Fifteen subjects had their corneas measured using a rotating Scheimpflug camera (Pentacam) every 3 to 7 h over a 24-h period. Anterior and posterior corneal axial curvature, pachymetry and anterior chamber depth were analyzed. The best fitting corneal sphero-cylinder from the axial curvature, and the average corneal thickness for a series of different corneal regions were calculated. Measures of intraocular pressure and axial length were also taken at each measurement session. RESULTS: Significant diurnal variation was found to occur in both the anterior and posterior corneal curvature and in the regional corneal thickness. Flattening of the anterior corneal best sphere was observed at the early morning measurement upon waking (p < 0.0001). The posterior cornea also underwent a significant steepening (p < 0.0001) and change in astigmatism 90/180 degrees at this time. A significant swelling of the cornea (p < 0.0001) was also evident upon waking. Highly significant associations were found between the diurnal variation in corneal thickness and the changes in corneal curvature. CONCLUSIONS: Small but significant diurnal variation occurs in the regional thickness and the shape of the anterior and posterior cornea. The largest changes in the cornea are typically evident upon waking. The regional corneal swelling observed at this time was not uniform, being slightly greater in peripheral corneal regions. The pattern of corneal swelling evident on waking resulted in a steepening of the posterior, and a flattening of the anterior corneal surface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thibos, L. N., WHEELER, W., & Horner, D. G. (1997) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1997.tb04707.x · Cited by 1,238
Bland, J. M., & Altman, D. G. (1995) · BMJ · doi:10.1136/bmj.310.6977.446 · Cited by 1,034
Ambrósio, R., Alonso, R. S., Luz, A., & Coca Velarde, L. G. (2006) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2006.06.025 · Cited by 451
The specific architecture of the anterior stroma accounts for maintenance of corneal curvature
Muller, L. J. (2001) · British Journal of Ophthalmology · doi:10.1136/bjo.85.4.437 · Cited by 424
The shape of the anterior and posterior surface of the aging human cornea
Dubbelman, M., Sicam, V. A. D. P., & Van der Heijde, G. L. (2006) · Vision Research · doi:10.1016/j.visres.2005.09.021 · Cited by 378
LACKNER, B., SCHMIDINGER, G., PIEH, S., FUNOVICS, M. A., & SKORPIK, C. (2005) · Optometry and Vision Science · doi:10.1097/01.opx.0000180817.46312.0a · Cited by 311
Barkana, Y., Gerber, Y., Elbaz, U., Schwartz, S., Ken-Dror, G., Avni, I., & Zadok, D. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2005.03.058 · Cited by 298
A new non-contact optical device for ocular biometry
Santodomingo-Rubido, J. (2002) · British Journal of Ophthalmology · doi:10.1136/bjo.86.4.458 · Cited by 294
Shankar, H., Taranath, D., Santhirathelagan, C. T., & Pesudovs, K. (2008) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2007.09.013 · Cited by 286
Comparison of Dynamic Contour Tonometry with Goldmann Applanation Tonometry
Kaufmann, C., Bachmann, L. M., & Thiel, M. A. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0018 · Cited by 281 · cited 1×
“The DCT has been found to exhibit good inter- and intra-observer repeatability, comparable to Goldmann applanation tonometry.(50) The tonometer’s calibration was checked using the Pascal tonometer performance test kit before commencement of the study.”
Method
Cited by
Diurnal Variations in Axial Length, Choroidal Thickness, Intraocular Pressure, and Ocular Biometrics
Chakraborty, R., Read, S. A., & Collins, M. J. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-7364 · Cited by 499
Self-citationCorneal Deformation Measurement Using Scheimpflug Noncontact Tonometry
Hon, Y., & Lam, A. K. C. (2013) · Optometry and Vision Science · doi:10.1097/opx.0b013e318279eb87 · Cited by 235
“It is well supported that diurnal variation exists for corneal thickness.(23,24) Increased corneal thickness (both central and peripheral) is shown immediately after waking because of overnight corneal swelling of approximately 2.”
Background
Metadata
- Authors
- Read, S. A., & Collins, M. J.
- Venue
- Optometry and Vision Science
- Publisher
- Wiley
- Published
- 2009-03
- Volume
- 86
- Issue
- 3
- Pages
- 170-180
- ISSN
- 1040-5488 (ISSN-L)
- OpenAlex
- W2048829657
- Cited by
- 182
- References
- 44
- FWCI
- 5.87
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diurnal Variation of Corneal Shape and Thickness. https://app.cochat.ai/papers/10.1097/opx.0b013e3181981b7e
- The paper
- Read, S. A., & Collins, M. J. (2009). Diurnal Variation of Corneal Shape and Thickness. Optometry and Vision Science. https://doi.org/10.1097/opx.0b013e3181981b7e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.