Cardiac performance in response to PEEP in patients with cardiac dysfunction
The DOI matches its Crossref record.
Abstract
The effect of PEEP on cardiac performance was evaluated in 21 patients with left ventricular (LV) dysfunction. Twenty-three data sets were divided into three groups according to pulmonary arterial wedge pressure (PAWP). In three of four group A data sets (PAWP = 12 mm Hg), cardiac output (CO) decreased when PEEP was added. In four of six group B data sets (PAWP = 14-18 mm Hg) and in 12 of 13 group C data sets (PAWP less than or equal to 19 mm Hg), CO increased with addition of PEEP. In group C, the mean increase in CO was 500 ml/min, and the mean level of best PEEP was 3.9 cm H2O. When PAWP exceeded 18 mm Hg, PEEP was safe and in many instances augmented CO.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
van Diepen, S., Katz, J. N., Albert, N. M., Henry, T. D., Jacobs, A. K., Kapur, N. K., Kilic, A., Menon, V., Ohman, E. M., Sweitzer, N. K., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000525 · Cited by 1,869
Adaptive Servo-Ventilation for Central Sleep Apnea in Systolic Heart Failure
Cowie, M. R., Woehrle, H., Wegscheider, K., Angermann, C., d’Ortho, M.-P., Erdmann, E., Levy, P., Simonds, A. K., Somers, V. K., Zannad, F., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1506459 · Cited by 1,107
Naughton, M. T., Rahman, M. A., Hara, K., Floras, J. S., & Bradley, T. D. (1995) · Circulation · doi:10.1161/01.cir.91.6.1725 · Cited by 466
Continuous positive airway pressure by face mask in acute cardiogenic pulmonary edema
Räsänen, J., Heikkilä, J., Downs, J., Nikki, P., Väisänen, I., & Viitanen, A. (1985) · The American Journal of Cardiology · doi:10.1016/0002-9149(85)90364-9 · Cited by 375
MICHARD, F., CHEMLA, D., RICHARD, C., WYSOCKI, M., PINSKY, M. R., LECARPENTIER, Y., & TEBOUL, J.-L. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.3.9805077 · Cited by 371
Naughton, M. T., Liu, P. P., Bernard, D. C., Goldstein, R. S., & Bradley, T. D. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.151.1.7812579 · Cited by 346
Ventilatory and hemodynamic effects of continuous positive airway pressure in left heart failure.
Lenique, F., Habis, M., Lofaso, F., Dubois-Randé, J. L., Harf, A., & Brochard, L. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.2.9032185 · Cited by 331
Reappraisal of Continuous Positive Airway Pressure Therapy in Acute Cardiogenic Pulmonary Edema
Lin, M., Yang, Y.-F., Chiang, H.-T., Chang, M.-S., Chiang, B. N., & Cheitlin, M. D. (1995) · Chest · doi:10.1378/chest.107.5.1379 · Cited by 322
Positive pressure ventilation in the cardiac intensive care unit
Alviar, C. L., Miller, P. E., McAreavey, D., Katz, J. N., Lee, B., Moriyama, B., Soble, J., van Diepen, S., Solomon, M. A., & Morrow, D. A. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.06.074 · Cited by 271
“In patients with elevated pulmonary capillary wedge pressure (PCWP), CO improves as PEEP is increased (from 0 to 8 cmH2O) (66); however, in patients with normal or low pulmonary capillary wedge pressure, PEEP may lower CO (61,67).”
BackgroundThe hemodynamic consequences of mechanical ventilation: an evolving story
Pinsky, M. R. (1997) · Intensive Care Medicine · doi:10.1007/s001340050364 · Cited by 202
Cheyne–Stokes respiration: friend or foe?: Figure 1
Naughton, M. T. (2012) · Thorax · doi:10.1136/thoraxjnl-2011-200927 · Cited by 191
“Fifth, the ‘apnoea’ in CSAeCSR, is more accurately described as a prolonged slow expiration during which the upper airway usually closes mid ‘apnoea’ resulting in 5e10 mm Hg ‘intrinsic’ positive end-expiratory pressure (PEEP) (see figure 1B) similar to that reported during wakefulness in HF over 75 years ago.34 Small…”
ResultInfluentialObesity-Hypoventilation Syndrome: Increased Risk of Death over Sleep Apnea Syndrome
Castro-Añón, O., Pérez de Llano, L. A., De la Fuente Sánchez, S., Golpe, R., Méndez Marote, L., Castro-Castro, J., & González Quintela, A. (2015) · PLOS ONE · doi:10.1371/journal.pone.0117808 · Cited by 174
“However, the theoretical concerns were not reproduced in the clinical setting and a number of mechanisms for the haemodynamic improvement observed with PEEP in patients with heart failure have been described [30].”
BackgroundFordyce, C. B., Katz, J. N., Alviar, C. L., Arslanian-Engoren, C., Bohula, E. A., Geller, B. J., Hollenberg, S. M., Jentzer, J. C., Sims, D. B., Washam, J. B., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000909 · Cited by 116
Metadata
- Authors
- GRACE, M. P., & GREENBAUM, D. M.
- Venue
- Critical Care Medicine
- Published
- 1982-06
- Volume
- 10
- Issue
- 6
- Pages
- 358-360
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2165999852
- Cited by
- 175
- References
- 0
- FWCI
- 4.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.