CoChat

Skeletal muscle partial pressure of oxygen in patients with sepsis

BOEKSTEGERS, PETER, WEIDENHÖFER, STEPHAN, KAPSNER, THOMAS, WERDAN, KARL · 1994 · Critical Care Medicine
Cited by 245

The DOI matches its Crossref record.

Abstract

OBJECTIVE: In order to obtain direct evidence for tissue hypoxia in patients with sepsis oxygen, partial pressure was measured within skeletal muscle. Furthermore, serial intermittent and continuous measurements of skeletal muscle PO2 in patients with sepsis were used to find out whether skeletal muscle oxygenation may change in the course of sepsis and depends on the severity of sepsis. DESIGN: Prospective study. SETTING: Intensive care unit of a university hospital. PATIENTS: Intensive care patients (n = 98) with sepsis (group 1, n = 39; group 4, n = 28), limited infection (group 2, n = 16), and cardiogenic shock (group 3, n = 15). INTERVENTIONS: Pulmonary artery catheterization; standard antibiotic therapy and volume replacement. MEASUREMENTS AND MAIN RESULTS: Skeletal muscle PO2 was determined by polarographic needle electrodes or catheter probes. In patients with sepsis (n = 67), no evidence for skeletal muscle hypoxia was obtained from the PO2 distribution within biceps muscle. Mean skeletal muscle PO2 was increased in patients with sepsis (group 1, 48 torr [6.4 kPa]) compared with patients with limited infection (group 2, 28 torr [3.7 kPa]), p < .001) and with patients with cardiogenic shock (group 3, 22 torr [2.9 kPa], p < .001). Serial measurements of the PO2 distribution during seven consecutive days in another 28 patients (group 4) with sepsis showed that a more severe degree of sepsis was associated with an increase of mean skeletal muscle (p < .001). These results were confirmed by continuous measurements of mean skeletal muscle PO2, using PO2 catheters. CONCLUSIONS: In patients with sepsis, oxygen transport to skeletal muscle was not critically reduced. Serial intermittent and continuous measurements of skeletal muscle PO2 showed that skeletal muscle PO2 increased in relation to the severity of the stage of sepsis. Our findings suggest that oxygen utilization within skeletal muscle decreased with deterioration of sepsis, thereby increasing skeletal muscle PO2.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-199404000-00021

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
BOEKSTEGERS, P., WEIDENHÖFER, S., KAPSNER, T., & WERDAN, K.
Venue
Critical Care Medicine
Published
1994-04
Volume
22
Issue
4
Pages
640-650
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2051179657
Cited by
245
References
0
FWCI
6.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.