CoChat

Poor prognosis for existing monitors in the intensive care unit

Tsien, Christine L., Fackler, James C. · 1997 · Critical Care Medicine
Cited by 309

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To identify areas requiring the most urgent improvement in the intensive care unit (ICU); and to accurately determine the positive predictive value of routine critical care patient monitoring alarms, as well as the common causes for false-positive alarms. DESIGN: Prospective, observational study. SETTING: A multidisciplinary ICU in a university-affiliated children's hospital (excluding children with primary heart disease). INTERVENTIONS: The occurrence rate, cause, and appropriateness of all alarms from tracked monitors were recorded by a trained observer and validated by the bedside nurse over a 10-wk period for a single bedspace at a time. MEASUREMENTS AND MAIN RESULTS: After 298 monitored hrs, 86% of a total 2,942 alarms were found to be false-positive alarms, while an additional 6% were classified as clinically irrelevant true alarms. Only 8% of all alarms tracked during the study period were determined to be true alarms with clinical significance. Alarms were also classified according to whether they were clearly associated with a "patient intervention" (18%), were clearly not associated with a patient intervention (74%), or had unclear association to interventions (8%). While 11% of "nonpatient intervention" alarms were clinically significant true alarms, only 2% of "patient intervention" alarms were so. Positive predictive values for the various devices ranged from < 1% for the pulse oximeter's heart rate signal to 74% for the arterial catheter's mean systemic blood pressure signal during periods free from patient interventions. The pulse oximeter caused false-positive alarms most frequently, with common reasons being bad data format/bad connection and poor contact. CONCLUSION: Efforts to develop intelligent monitoring systems have more potential to deliver significantly improved patient care by initially targeting especially weak areas in ICU monitoring, such as pulse oximetry reliability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-199704000-00010

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 5

  1. Sara, 1986, Anaesth Intensive Care, 14, 448, 10.1177/0310057X8601400421 · doi:10.1177/0310057x8601400421
  2. Finley, 1991, Can J Anaesth, 38, 958, 10.1007/BF03008611 · doi:10.1007/bf03008611
  3. Crew, 1991, Intensive Care Med, 17, 359, 10.1007/BF01716197 · doi:10.1007/bf01716197
  4. Koski, 1992, Int J Clin Monit Comput, 8, 289, 10.1007/BF01739130 · doi:10.1007/bf01739130
  5. Fukui, 1989, J Clin Monit, 5, 211, 10.1007/BF01627458 · doi:10.1007/bf01627458

Cited by

See all 309

Metadata

Authors
Tsien, C. L., & Fackler, J. C.
Venue
Critical Care Medicine
Published
1997-04
Volume
25
Issue
4
Pages
614-619
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2002971490
Cited by
309
References
8
FWCI
8.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.