Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 304

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Assessing sedation during intensive care unit mechanical ventilation with the Bispectral Index and the Sedation-Agitation Scale

Simmons, LaVone E., Riker, Richard R., Prato, B. Stephen, Fraser, Gilles L.·1999·Critical Care Medicine

Abstract

OBJECTIVE: To describe the level of sedation for a cohort of mechanically ventilated adult intensive care unit (ICU) patients using validated subjective and objective tools. DESIGN: Prospective convenience sample. SETTING: Multidisciplinary 34-bed ICU at Maine Medical Center, a 599-bed nonuniversity, academic medical center. PATIENTS: Sixty-three adult ICU patients were monitored during 64 episodes of ventilatory support. MEASUREMENTS AND MAIN RESULTS: Patients were prospectively evaluated by one trained investigator using the revised Sedation-Agitation Scale (SAS) and were simultaneously monitored for 1 to 5 hrs using the Bispectral Index (BIS), a numeric scale from 0 to 100 derived from the electroencephalogram. BIS values were assigned to baseline, stimulated, and average conditions for each patient by a separate investigator blinded to SAS scores. Ventilator settings, medications, and the lung injury severity (LIS) score were also recorded. Sedation levels varied from very deep sedation (SAS score = 1, BIS score = 43) to mild agitation (SAS score = 5, BIS score = 100). Heavily sedated patients (SAS score = 1-2, n = 20) had higher FIO2 (0.52 vs. 0.42, p = .008), oxygenation index (9.4 vs. 5.4, p = .03), and LIS scores (1.3 vs. 0.7, p = .004) and lower baseline (66 vs. 78, p = .01), average (66 vs. 81, p < .001), and stimulated (89 vs. 96, p = .016) BIS scores compared with more awake patients. Patients with intermittent neuromuscular blockade use (n = 4) had higher FIO2 (0.65 vs. 0.44, p = .006), minute ventilation (14.6 vs. 9.9 L/min, p = .005), positive end-expiratory pressure (7.5 vs. 4.8 cm H2O, p = .05), oxygenation index (15.7 vs. 6.0, p < .001), and LIS scores (3.3 vs. 1.0, p = .036) and were more sedated, with higher suppression ratios (3.5 vs. 0.6, p = .05) and lower SAS scores (1.5 vs. 4, p = .035). The average BIS values correlated well with SAS (r2 = .21, p < .001). CONCLUSIONS: SAS and BIS work well to describe the depth of sedation for ventilated ICU patients. Deeper sedation and intermittent neuromuscular blockade were used for patients with greater ventilatory requirements and more severe lung disease. The correlation between subjective and objective scales varied in medical, surgical, and trauma patients. Further research with SAS and BIS may facilitate the development of quantitative sedation guidelines for the ICU.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-199908000-00016

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 304

Metadata

Authors
Simmons, L. E., Riker, R. R., Prato, B. S., & Fraser, G. L.
Venue
Critical Care Medicine
Published
1999-08
Volume
27
Issue
8
Pages
1499-1504
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2074068229
Cited by
304
References
22
FWCI
16.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessing sedation during intensive care unit mechanical ventilation with the Bispectral Index and the Sedation-Agitation Scale. https://app.cochat.ai/papers/10.1097/00003246-199908000-00016
The paper
Simmons, L. E., Riker, R. R., Prato, B. S., & Fraser, G. L. (1999). Assessing sedation during intensive care unit mechanical ventilation with the Bispectral Index and the Sedation-Agitation Scale. Critical Care Medicine. https://doi.org/10.1097/00003246-199908000-00016

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.