Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,013

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Effect of a nursing-implemented sedation protocol on the duration of mechanical ventilation

Brook, Alan D., Ahrens, Thomas S., Schaiff, Robyn, Prentice, Donna, Sherman, Glenda, Shannon, William, Kollef, Marin H.·1999·Critical Care Medicine

Abstract

OBJECTIVE: To compare a practice of protocol-directed sedation during mechanical ventilation implemented by nurses with traditional non-protocol-directed sedation administration. DESIGN: Randomized, controlled clinical trial. SETTING: Medical intensive care unit (19 beds) in an urban teaching hospital. PATIENTS: Patients requiring mechanical ventilation (n = 321). INTERVENTIONS: Patients were randomly assigned to receive either protocol-directed sedation (n = 162) or non-protocol-directed sedation (n = 159). MEASUREMENTS AND MAIN RESULTS: The median duration of mechanical ventilation was 55.9 hrs (95% confidence interval, 41.0-90.0 hrs) for patients managed with protocol-directed sedation and 117.0 hrs (95% confidence interval, 96.0-155.6 hrs) for patients receiving non-protocol-directed sedation. Kaplan-Meier analysis demonstrated that patients in the protocol-directed sedation group had statistically shorter durations of mechanical ventilation than patients in the non-protocol-directed sedation group (chi-square = 7.00, p = .008, log rank test; chi-square = 8.54, p = .004, Wilcoxon's test; chi-square = 9.18, p = .003, -2 log test). Lengths of stay in the intensive care unit (5.7+/-5.9 days vs. 7.5+/-6.5 days; p = .013) and hospital (14.0+/-17.3 days vs. 19.9+/-24.2 days; p < .001) were also significantly shorter among patients in the protocol-directed sedation group. Among the 132 patients (41.1%) receiving continuous intravenous sedation, those in the protocol-directed sedation group (n = 66) had a significantly shorter duration of continuous intravenous sedation than those in the non-protocol-directed sedation group (n = 66) (3.5+/-4.0 days vs. 5.6+/-6.4 days; p = .003). Patients in the protocol-directed sedation group also had a significantly lower tracheostomy rate compared with patients in the non-protocol-directed sedation group (10 of 162 patients [6.2%] vs. 21 of 159 patients [13.2%], p = .038). CONCLUSIONS: The use of protocol-directed sedation can reduce the duration of mechanical ventilation, the intensive care unit and hospital lengths of stay, and the need for tracheostomy among critically ill patients with acute respiratory failure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-199912000-00001

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 1,013

Metadata

Authors
Brook, A. D., Ahrens, T. S., Schaiff, R., Prentice, D., Sherman, G., Shannon, W., & Kollef, M. H.
Venue
Critical Care Medicine
Published
1999-12
Volume
27
Issue
12
Pages
2609-2615
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2160359556
Cited by
1,013
References
24
FWCI
20.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of a nursing-implemented sedation protocol on the duration of mechanical ventilation. https://app.cochat.ai/papers/10.1097/00003246-199912000-00001
The paper
Brook, A. D., Ahrens, T. S., Schaiff, R., Prentice, D., Sherman, G., Shannon, W., & Kollef, M. H. (1999). Effect of a nursing-implemented sedation protocol on the duration of mechanical ventilation. Critical Care Medicine. https://doi.org/10.1097/00003246-199912000-00001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.