Fibrin sheath enhances central venous catheter infection
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine whether fibrin-coated central venous catheters have a higher infection rate, and spawn more septic emboli, than uncoated catheters after exposure to bacteremia. DESIGN: Animal study comparing catheter infection and blood cultures of fibrin-coated and uncoated catheters exposed to bacteremia. SETTING: Animal laboratory. SUBJECTS: Adult male Sprague-Dawley rats. INTERVENTIONS: A total of 210 rats had catheters placed with the proximal end buried subcutaneously. Rats were divided into three groups: tail vein bacterial injection on day 0 (no fibrin group) or on day 10 (fibrin group), or no injection/saline injection (control, n = 40). Bacterial injections were 1 x 108 colony forming units of either Staphylococcus epidermidis (n = 100) or Enterobacter cloacae (n = 60). Animals were killed 3 days after injection. Blood cultures were obtained via cardiac puncture, and catheters were removed via the chest. Half of the catheter was rolled onto agar and the other half was placed in trypticase soy broth. Plates and broth were incubated at 37 degrees C for 48 hrs. The presence of >15 colonies on roll plates, or growth in broth, was accepted as a positive sign of infection. Microscopy was performed on day 20-10 catheters. Thirty animals without catheters had bacterial injections and underwent blood culture 3 days after injection. MEASUREMENTS AND MAIN RESULTS: Catheter infection with S. epidermidis occurred in 32% of roll plates and 80% of broth from the fibrin group vs. 4% and 20% from the no fibrin group (p <.01 for each). Catheter infection with E. cloacae occurred in 50% of roll plates and 80% of broth from the fibrin group vs. 0% and 12% from the no fibrin group (p <.01 for each). Positive blood cultures occurred in 47 of 68 animals from the fibrin group vs. 8 of 68 from the no fibrin group (p <.01). Microscopy showed a fibrin sheath on 20 of 20 catheters. Without catheters, 30 of 30 blood cultures were negative. CONCLUSION: The fibrin sheath significantly enhanced catheter-related infection and persistent bacteremia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomaterial-Centered Infection: Microbial Adhesion Versus Tissue Integration
Gristina, A. G. (1987) · Science · doi:10.1126/science.3629258 · Cited by 2,156
A Semiquantitative Culture Method for Identifying Intravenous-Catheter-Related Infection
Maki, D. G., Weise, C. E., & Sarafin, H. W. (1977) · New England Journal of Medicine · doi:10.1056/nejm197706092962301 · Cited by 2,027 · cited 1×
“The distal half of the catheter was removed and rolled onto a 5% sheep blood agar plate according to the technique described by Maki et al (25).”
MethodMajor trends in the microbial etiology of nosocomial infection
Schaberg, D. R., Culver, D. H., & Gaynes, R. P. (1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)90346-y · Cited by 1,109 · cited 2×
“Catheter infection develops via several routes (1, 2): exogenously, i.”
BackgroundPittet, D. (1994) · JAMA · doi:10.1001/jama.1994.03510440058033 · Cited by 926
Secular trends in nosocomial primary bloodstream infections in the United States, 1980–1989.
Banerjee, S. N., Emori, T. G., Culver, D. H., Gaynes, R. P., Jarvis, W. R., Horan, T., Edwards, J. R., Tolson, J., Henderson, T., Martone, W. J., et al. (1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)90349-3 · Cited by 880
Adherence and Growth of Coagulase-Negative Staphylococci on Surfaces of Intravenous Catheters
Peters, G., Locci, R., & Pulverer, G. (1982) · Journal of Infectious Diseases · doi:10.1093/infdis/146.4.479 · Cited by 559
Raad, I., Costerton, W., Sabharwal, U., Sadlowski, M., Anaissie, E., & Bodey, G. P. (1993) · Journal of Infectious Diseases · doi:10.1093/infdis/168.2.400 · Cited by 553 · cited 1×
“Exogenous catheter contamination has been studied extensively by many authors, who have shown correlation between infecting organisms and the flora of the skin surrounding the exit site (3–6), the hub (8, 7, 13, 14), and the hands of healthcare workers (20).”
BackgroundGuideline for Prevention of Intravascular-Device-Related Infections
Pearson, M. L., & The Hospital Infection Control Practices Advisory Committee (1996) · Infection Control and Hospital Epidemiology · doi:10.2307/30141155 · Cited by 531
Herrmann, M., Vaudaux, P. E., Pittet, D., Auckenthaler, R., Lew, P. D., Perdreau, F. S., Peters, G., & Waldvogel, F. A. (1988) · The Journal of Infectious Diseases · doi:10.1093/infdis/158.4.693 · Cited by 522
Liñares, J., Sitges-Serra, A., Garau, J., Pérez, J. L., & Martín, R. (1985) · Journal of Clinical Microbiology · doi:10.1128/jcm.21.3.357-360.1985 · Cited by 474
Mack, D., Siemssen, N., & Laufs, R. (1992) · Infection and Immunity · doi:10.1128/iai.60.5.2048-2057.1992 · Cited by 372 · cited 1×
“epidermidis isolated from an infected patient’s catheter and previously described (38) was used for this study.”
MethodFibrin Sleeve Formation on Indwelling Subclavian Central Venous Catheters
Hoshal, V. L. (1971) · Archives of Surgery · doi:10.1001/archsurg.1971.01350040115023 · Cited by 368 · cited 1×
“This fibrin sheath rapidly forms around intravenous catheters within 24 hrs, and then continues to evolve over weeks and months to contain collagen and even smooth muscle (21, 39).”
BackgroundCoagulase-Negative Staphylococcal Bacteremia: Mortality and Hospital Stay
Martin, M. A., Pfaller, M. A., & Wenzel, R. P. (1989) · Annals of Internal Medicine · doi:10.7326/0003-4819-110-1-9 · Cited by 333
Gray, E. D., Verstegen, M., Peters, G., & Regelmann, W. E. (1984) · The Lancet · doi:10.1016/s0140-6736(84)90413-6 · Cited by 289 · cited 1×
“Some authors have shown the fibrin sheath to be protective against bacterial colonization and infection by preventing bacterial adherence (40), whereas others have shown that the fibrin sheath interferes with granulocyte and immune function (37, 41) and inhibits the action of glycopeptide antibiotics (42).”
BackgroundConsequences of Intravascular Catheter Sepsis
Arnow, P. M., Quimosing, E. M., & Beach, M. (1993) · Clinical Infectious Diseases · doi:10.1093/clind/16.6.778 · Cited by 283
BJORNSON, H. S., COLLEY, R., Bower, R. H., Duty, V. P., Schwartz-Fulton, J., & Fischer, J. E. (1982) · PubMed · Cited by 272
Nationwide epidemic of septicemia caused by contaminated intravenous products
Maki, D. G., Rhame, F. S., Mackel, D. C., & Bennett, J. V. (1976) · The American Journal of Medicine · doi:10.1016/0002-9343(76)90713-0 · Cited by 260
Interference with granulocyte function by Staphylococcus epidermidis slime
Johnson, G. M., Lee, D. A., Regelmann, W. E., Gray, E. D., Peters, G., & Quie, P. G. (1986) · Infection and Immunity · doi:10.1128/iai.54.1.13-20.1986 · Cited by 245 · cited 2×
“Some authors have shown the fibrin sheath to be protective against bacterial colonization and infection by preventing bacterial adherence (40), whereas others have shown that the fibrin sheath interferes with granulocyte and immune function (37, 41) and inhibits the action of glycopeptide antibiotics (42).”
BackgroundVaudaux, P., Pittet, D., Haeberli, A., Huggler, E., Nydegger, U. E., Lew, D. P., & Waldvogel, F. A. (1989) · Journal of Infectious Diseases · doi:10.1093/infdis/160.5.865 · Cited by 234 · cited 2×
“In vitro evidence suggests that the fibrin sheath promotes adherence of coagulase-negative staphylococci to artificial surfaces (34, 44).”
BackgroundReed, C. D., & Tolley, J. (1967) · PubMed · Cited by 218
Salzman, M. B., Isenberg, H. D., Shapiro, J. F., Lipsitz, P. J., & Rubin, L. G. (1993) · Journal of Infectious Diseases · doi:10.1093/infdis/167.2.487 · Cited by 214
Farber, B. F., Kaplan, M. H., & Clogston, A. G. (1990) · Journal of Infectious Diseases · doi:10.1093/infdis/161.1.37 · Cited by 211 · cited 1×
“Some authors have shown the fibrin sheath to be protective against bacterial colonization and infection by preventing bacterial adherence (40), whereas others have shown that the fibrin sheath interferes with granulocyte and immune function (37, 41) and inhibits the action of glycopeptide antibiotics (42).”
BackgroundCooper, G. L., & Hopkins, C. C. (1985) · New England Journal of Medicine · doi:10.1056/nejm198505023121802 · Cited by 185
Haley, R. W., Schaberg, D. R., Von Allmen, S. D., & McGowan, J. E. (1980) · Journal of Infectious Diseases · doi:10.1093/infdis/141.2.248 · Cited by 175 · cited 1×
“Moreover, the use of catheters and the incidence of infections are both increasing (28, 30, 31).”
BackgroundDickinson, G. M., & Bisno, A. L. (1989) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.33.5.597 · Cited by 173 · cited 2×
“The presence of biofilm has been shown to aid in attachment and to protect against the cellular immune response (36, 37).”
BackgroundMaki, D. G., & Martin, W. T. (1975) · The Journal of Infectious Diseases · doi:10.1093/infdis/131.3.267 · Cited by 171
Composition and formation of the sleeve enveloping a central venous catheter
Xiang, D. Z., Verbeken, E. K., Van Lommel, A. T. L., Stas, M., & De Wever, I. (1998) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(98)70162-4 · Cited by 170 · cited 1×
“The sequential development and maturation of the fibrin sheath in rats has been well characterized microscopically by Xiang et al (23).”
Molecular mechanisms of Staphylococcus epidermidis biofilm formation
Mack, D. (1999) · Journal of Hospital Infection · doi:10.1016/s0195-6701(99)90074-9 · Cited by 163 · cited 1×
“Whether bacteria migrate from exogenous sources or encounter the catheter via hematogenous spreading, the first step in colonization and infection is adherence and attachment to the catheter (33).”
BackgroundEtiology of Catheter-Associated Sepsis: Correlation With Thrombogenicity
Stillman, R. M., Soliman, F., Garcia, L., & SAWYER, P. N. (1977) · Archives of Surgery · doi:10.1001/archsurg.1977.01370120087011 · Cited by 163
Sitges‐Serra, A., Liñares, J., Pérez, J. L., Jaurrieta, E., & Lorente, L. (1985) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607185009003322 · Cited by 160
Pettigrew, R. A., Lang, S. D. R., Haydock, D. A., Parry, B. R., Bremner, D. A., & Hill, G. L. (1985) · Journal of British Surgery · doi:10.1002/bjs.1800720121 · Cited by 159
Foreign Body Infection: Role of Fibronectin as a Ligand for the Adherence of Staphylococcus aureus
Vaudaux, P. E., Suzuki, R., Waldvogel, F. A., Morgenthaler, J. ‐., & Nydegger, U. E. (1984) · The Journal of Infectious Diseases · doi:10.1093/infdis/150.4.546 · Cited by 157
Vaudaux, P. E., Pittet, D., Haeberli, A., Lerch, P. G., Morgenthaler, J. ‐., Proctor, R. A., Waldvogel, F. A., & Lew, D. P. (1993) · The Journal of Infectious Diseases · doi:10.1093/infdis/167.3.633 · Cited by 142
SOURCE AND ROUTE OF MICROBIAL COLONISATION OF PARENTERAL NUTRITION CATHETERS
Cicco, M. D., Chiaradia, V., Veronesi, A., Santini, G., Panarello, G., Fracasso, A., Testa, V., & Tesio, F. (1989) · The Lancet · doi:10.1016/s0140-6736(89)91861-8 · Cited by 101 · cited 1×
“Exogenous catheter contamination has been studied extensively by many authors, who have shown correlation between infecting organisms and the flora of the skin surrounding the exit site (3–6), the hub (8, 7, 13, 14), and the hands of healthcare workers (20).”
BackgroundIn-Use Contamination of Intravenous Infusion Fluid
Maki, D. G., Anderson, R. L., & Shulman, J. A. (1974) · Applied Microbiology · doi:10.1128/am.28.5.778-784.1974 · Cited by 53
Raja, R. H., Raucci, G., & Höök, M. (1990) · Infection and Immunity · doi:10.1128/iai.58.8.2593-2598.1990 · Cited by 51
Cited by
Tong, S. Y. C., Davis, J. S., Eichenberger, E., Holland, T. L., & Fowler, V. G. (2015) · Clinical Microbiology Reviews · doi:10.1128/cmr.00134-14 · Cited by 5,192
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
KDOQI Clinical Practice Guideline for Vascular Access: 2019 Update
Lok, C. E., Huber, T. S., Lee, T., Shenoy, S., Yevzlin, A. S., Abreo, K., Allon, M., Asif, A., Astor, B. C., Glickman, M. H., et al. (2020) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2019.12.001 · Cited by 2,590
Guidelines for the prevention of intravascular catheter-related infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2011.01.003 · Cited by 1,066
“Due to the formation of the fibrin sheath, silastic catheters are associated with higher risk of catheter infections than polyurethane catheters [217].”
Management of occlusion and thrombosis associated with long-term indwelling central venous catheters
Baskin, J. L., Pui, C.-H., Reiss, U., Wilimas, J. A., Metzger, M. L., Ribeiro, R. C., & Howard, S. C. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60220-8 · Cited by 445
Metadata
- Authors
- Mehall, J. R., Saltzman, D. A., Jackson, R. J., & Smith, S. D.
- Venue
- Critical Care Medicine
- Published
- 2002-04
- Volume
- 30
- Issue
- 4
- Pages
- 908-912
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W1972862300
- Cited by
- 170
- References
- 36
- FWCI
- 5.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.