CoChat

Effects of the Number of Channels and Speech-to-Noise Ratio on Rate of Connected Discourse Tracking Through a Simulated Cochlear Implant Speech Processor

Faulkner, A., Rosen, S., Wilkinson, L. · 2001 · Ear and Hearing
Cited by 37

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To investigate the effects of number of channels and speech-to-noise ratio on connected discourse tracking (CDT) through simulations of cochlear implant speech processing. Previous studies have used citation-form vowel and consonant materials or simple sentences. CDT rates were expected to be less likely to be limited by ceiling effects and more representative of everyday speech communication. DESIGN: Four normal-hearing subjects were presented with speech processed through a real-time sine-excited vocoder having three, four, eight, or 12 channels. Amplitude envelopes extracted from each band modulated sinusoidal carrier signals placed at each band center frequency. Speech-spectrum shaped noise was added to speech before vocoder processing at three signal to noise ratios based on real-time measurements of speech level (+7, +12, +17 dB). RESULTS: CDT rates increased significantly with number of channels up to eight in both quiet and noise, and decreased significantly with each increase in noise level from quiet. CONCLUSIONS: The effects on CDT rates of the number of channels and speech-to-noise ratio are highly correlated with intelligibility measures for Hearing in Noise Test (HINT) sentences, consonants and vowels. However, HINT sentence scores even in noise show ceiling effects that obscure the advantages of processors with eight or more channels. Moderate levels of noise that have only slight effects on other measures significantly affected CDT rate. CDT rates with three or four bands of spectral information were much lower than asymptotic rates, especially in the presence of noise.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003446-200110000-00007

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 37

Metadata

Authors
Faulkner, A., Rosen, S., & Wilkinson, L.
Venue
Ear and Hearing
Published
2001-10
Volume
22
Issue
5
Pages
431-438
ISSN
0196-0202 (ISSN-L)
OpenAlex
W1998260046
Cited by
37
References
1
FWCI
0.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of the Number of Channels and Speech-to-Noise Ratio on Rate of Connected Discourse Tracking Through a Simulated Cochlear Implant Speech Processor. https://app.cochat.ai/papers/10.1097/00003446-200110000-00007
The paper
Faulkner, A., Rosen, S., & Wilkinson, L. (2001). Effects of the Number of Channels and Speech-to-Noise Ratio on Rate of Connected Discourse Tracking Through a Simulated Cochlear Implant Speech Processor. Ear and Hearing. https://doi.org/10.1097/00003446-200110000-00007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.