A Multicenter Clinical Trial of a Biosynthetic Skin Replacement, Dermagraft-TC, Compared with Cryopreserved Human Cadaver Skin for Temporary Coverage of Excised Burn Wounds
Abstract
This multicenter study compared the use of a biosynthetic human skin substitute with frozen human cadaver allograft for the temporary closure of excised burn wounds. Dermagraft-TC (Advanced Tissue Sciences, Inc.) (DG-TC) consists of a synthetic material onto which human neonatal fibroblasts are cultured. Burn wounds in 66 patients with a mean age of 36 years and a mean burn size of 44% total body surface area (28% total body surface area full-thickness) were surgically excised. Two comparable sites, each approximately 1% total body surface area in size, were randomized to receive either DG-TC or allograft. Both sites were then treated in the same manner. When clinically indicated (> 5 days after application) both skin replacements were removed, and the wound beds were evaluated and prepared for grafting. DG-TC was equivalent or superior to allograft with regard to autograft take at postautograft day 14. DG-TC was also easier to remove, had no epidermal slough, and resulted in less bleeding than did allograft while maintaining an adequate wound bed. Overall satisfaction was better with DG-TC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tissue Engineering and Regenerative Medicine: History, Progress, and Challenges
Berthiaume, F., Maguire, T. J., & Yarmush, M. L. (2011) · Annual Review of Chemical and Biomolecular Engineering · doi:10.1146/annurev-chembioeng-061010-114257 · Cited by 734
Support of the metabolic response to burn injury
Herndon, D. N., & Tompkins, R. G. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16360-5 · Cited by 532
Self-citationHróbjartsson, A., Thomsen, A. S. S., Emanuelsson, F., Tendal, B., Hilden, J., Boutron, I., Ravaud, P., & Brorson, S. (2013) · Canadian Medical Association Journal · doi:10.1503/cmaj.120744 · Cited by 527
Synthetic polymeric biomaterials for wound healing: a review
Mir, M., Ali, M. N., Barakullah, A., Gulzar, A., Arshad, M., Fatima, S., & Asad, M. (2018) · Progress in Biomaterials · doi:10.1007/s40204-018-0083-4 · Cited by 525
Engineered skin substitutes: practices and potentials
Supp, D. M., & Boyce, S. T. (2005) · Clinics in Dermatology · doi:10.1016/j.clindermatol.2004.07.023 · Cited by 520
Metadata
- Authors
- Purdue, G. F., Hunt, J. L., Still, J. M., Law, E. J., Herndon, D. N., Goldfarb, I. W., Schiller, W. R., Hansbrough, J. F., Hickerson, W. L., Himel, H. N., Kealey, G. P., Twomey, J., Missavage, A. E., Solem, L. D., Davis, M., Totoritis, M., & Gentzkow, G. D.
- Venue
- Journal of Burn Care & Rehabilitation
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-01
- Volume
- 18
- Issue
- 1
- Pages
- 52-57
- ISSN
- 0273-8481 (ISSN-L)
- OpenAlex
- W2035055796
- Cited by
- 174
- References
- 0
- FWCI
- 4.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Multicenter Clinical Trial of a Biosynthetic Skin Replacement, Dermagraft-TC, Compared with Cryopreserved Human Cadaver Skin for Temporary Coverage of Excised Burn Wounds. https://app.cochat.ai/papers/10.1097/00004630-199701000-00009
- The paper
- Purdue, G. F., Hunt, J. L., Still, J. M., Law, E. J., Herndon, D. N., Goldfarb, I. W., Schiller, W. R., Hansbrough, J. F., Hickerson, W. L., Himel, H. N., Kealey, G. P., Twomey, J., Missavage, A. E., Solem, L. D., Davis, M., Totoritis, M., & Gentzkow, G. D. (1997). A Multicenter Clinical Trial of a Biosynthetic Skin Replacement, Dermagraft-TC, Compared with Cryopreserved Human Cadaver Skin for Temporary Coverage of Excised Burn Wounds. Journal of Burn Care & Rehabilitation. https://doi.org/10.1097/00004630-199701000-00009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.