Noninvasive Measurement of Regional Cerebral Blood Flow by Near-Infrared Spectroscopy and Indocyanine Green
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Clinicians lack a practical method for measuring CBF rapidly, repeatedly, and noninvasively at the bedside. A new noninvasive technique for estimation of cerebral hemodynamics by use of near-infrared spectroscopy (NIRS) and an intravenously infused tracer dye is proposed. Kinetics of the infrared tracer indocyanine green were monitored on the intact skull in pigs. According to an algorithm derived from fluorescein flowmetry, a relative blood flow index (BFI) was calculated. Data obtained were compared with cerebral and galeal blood flow values assessed by radioactive microspheres under baseline conditions and during hemorrhagic shock and resuscitation. Blood flow index correlated significantly ( r s = 0.814, P < 0.001) with cortical blood flow but not with galeal blood flow ( r s = 0.258). However, limits of agreement between BFI and CBF are rather wide (± 38.2 ± 6.4 mL 100 g−1 min−1) and require further studies. Data presented demonstrate that detection of tracer kinetics in the cerebrovasculature by NIRS may serve as valuable tool for the noninvasive estimation of regional CBF. Indocyanine green dilution curves monitored noninvasively on the intact skull by NIRS reflect dye passage through the cerebral, not extracerebral, circulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries
Aaslid, R., Markwalder, T.-M., & Nornes, H. (1982) · Journal of Neurosurgery · doi:10.3171/jns.1982.57.6.0769 · Cited by 3,046
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Kety, S. S., & Schmidt, C. F. (1948) · Journal of Clinical Investigation · doi:10.1172/jci101994 · Cited by 2,059
Blood flow measurements with radionuclide-labeled particles
Heymann, M. A., Payne, B. D., Hoffman, J. I. E., & Rudolph, A. M. (1977) · Progress in Cardiovascular Diseases · doi:10.1016/s0033-0620(77)80005-4 · Cited by 2,036
Frackowiak, R. S. J., Lenzi, G.-L., Jones, T., & Heather, J. D. (1980) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198012000-00001 · Cited by 1,242
Some sources of error in measuring regional blood flow with radioactive microspheres.
Buckberg, G. D., Luck, J. C., Payne, D. B., Hoffman, J. I., Archie, J. P., & Fixler, D. E. (1971) · Journal of Applied Physiology · doi:10.1152/jappl.1971.31.4.598 · Cited by 1,132
INDOCYANINE GREEN: OBSERVATIONS ON ITS PHYSICAL PROPERTIES, PLASMA DECAY, AND HEPATIC EXTRACTION*
Cherrick, G. R., Stein, S. W., Leevy, C. M., & Davidson, C. S. (1960) · Journal of Clinical Investigation · doi:10.1172/jci104072 · Cited by 979
Wray, S., Cope, M., Delpy, D. T., Wyatt, J. S., & Reynolds, E. O. R. (1988) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/0005-2728(88)90069-2 · Cited by 912
Cited by
Near-Infrared Spectroscopy in Bio-Applications
Beć, K. B., Grabska, J., & Huck, C. W. (2020) · Molecules · doi:10.3390/molecules25122948 · Cited by 471
Near‐infrared spectroscopy for monitoring muscle oxygenation
Boushel, R., & Piantadosi, C. A. (2000) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.2000.00713.x · Cited by 299
Direct measurement of tissue blood flow and metabolism with diffuse optics
Mesquita, R. C., Durduran, T., Yu, G., Buckley, E. M., Kim, M. N., Zhou, C., Choe, R., Sunar, U., & Yodh, A. G. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0232 · Cited by 195
Early Experience with Fluorescent Angiography in Free-Tissue Transfer Reconstruction
Pestana, I. A., Coan, B., Erdmann, D., Marcus, J., Levin, L. S., & Zenn, M. R. (2009) · Plastic and Reconstructive Surgery · doi:10.1097/prs.0b013e31819e67c1 · Cited by 191
Can the cerebral metabolic rate of oxygen be estimated with near-infrared spectroscopy?
Boas, D. A., Strangman, G., Culver, J. P., Hoge, R. D., Jasdzewski, G., Poldrack, R. A., Rosen, B. R., & Mandeville, J. B. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/15/311 · Cited by 175
Boushel, R., Langberg, H., Olesen, J., Nowak, M., Simonsen, L., Bülow, J., & Kjær, M. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.5.1868 · Cited by 163
“Recently, this technique has been validated with other methods for resting cerebral blood flow measurements in human infants (21, 27) and in pigs (15).”
Method
Metadata
- Authors
- Kuebler, W. M., Sckell, A., Habler, O., Kleen, M., Kuhnle, G. E. H., Welte, M., Messmer, K., & Goetz, A. E.
- Venue
- Journal of Cerebral Blood Flow & Metabolism
- Publisher
- SAGE Publications
- Published
- 1998-04
- Volume
- 18
- Issue
- 4
- Pages
- 445-456
- ISSN
- 0271-678X (ISSN-L)
- 1559-7016
- OpenAlex
- W2087825415
- Cited by
- 206
- References
- 38
- FWCI
- 3.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.