Linear and Nonlinear Current Density Reconstructions
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Minimum norm algorithms for EEG source reconstruction are studied in view of their spatial resolution, regularization, and lead-field normalization properties, and their computational efforts. Two classes of minimum norm solutions are examined: linear least squares methods and nonlinear L1-norm approaches. Two special cases of linear algorithms, the well known Minimum Norm Least Squares and an implementation with Laplacian smoothness constraints, are compared to two nonlinear algorithms comprising sparse and standard L1-norm methods. In a signal-to-noise-ratio framework, two of the methods allow automatic determination of the optimum regularization parameter. Compensation methods for the different depth dependencies of all approaches by lead-field normalization are discussed. Simulations with tangentially and radially oriented test dipoles at two different noise levels are performed to reveal and compare the properties of all approaches. Finally, cortically constrained versions of the algorithms are applied to two epileptic spike data sets and compared to results of single equivalent dipole fits and spatiotemporal source models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simplex Method for Function Minimization
Nelder, J. A., & Mead, R. (1965) · The Computer Journal · doi:10.1093/comjnl/7.4.308 · Cited by 28,905
Analysis of Discrete Ill-Posed Problems by Means of the L-Curve
Hansen, P. C. (1992) · SIAM Review · doi:10.1137/1034115 · Cited by 3,903
Automatic 3D intersubject registration of MR volumetric data in standardized Talairach space
Collins, D. L., Neelin, P., Peters, T. M., & Evans, A. C. (1994) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199403000-00005 · Cited by 3,431
Pascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869
Dale, A. M., & Sereno, M. I. (1993) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1993.5.2.162 · Cited by 2,003
Interpreting magnetic fields of the brain: minimum norm estimates
Hämäläinen, M. S., & Ilmoniemi, R. J. (1994) · Medical & Biological Engineering & Computing · doi:10.1007/bf02512476 · Cited by 1,995
Multiple dipole modeling and localization from spatio-temporal MEG data
Mosher, J. C., Lewis, P. S., & Leahy, R. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141192 · Cited by 1,048
Realistic conductivity geometry model of the human head for interpretation of neuromagnetic data
Hamalainen, M. S., & Sarvas, J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16463 · Cited by 989
Numerical Applications of a Formalism for Geophysical Inverse Problems
Backus, G. E., & Gilbert, J. F. (1967) · Geophysical Journal International · doi:10.1111/j.1365-246x.1967.tb02159.x · Cited by 943
Two bilateral sources of the late AEP as identified by a spatio-temporal dipole model
Scherg, M., & Von Cramon, D. (1985) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(85)90033-4 · Cited by 683
Cited by
MNE software for processing MEG and EEG data
Gramfort, A., Luessi, M., Larson, E., Engemann, D. A., Strohmeier, D., Brodbeck, C., Parkkonen, L., & Hämäläinen, M. S. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.10.027 · Cited by 1,951
Michel, C. M., Murray, M. M., Lantz, G., Gonzalez, S., Spinelli, L., & Grave de Peralta, R. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.001 · Cited by 1,655
Spatiotemporal Analysis of Multichannel EEG: CARTOOL
Brunet, D., Murray, M. M., & Michel, C. M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/813870 · Cited by 731
Multiple sparse priors for the M/EEG inverse problem.
Friston, K., Harrison, L., Daunizeau, J., Kiebel, S., Phillips, C., Trujillo-Barreto, N., Henson, R., Flandin, G., & Mattout, J. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.09.048 · Cited by 589
“To emphasize the superiority of the MSP solutions, we examined them for a common failing of simple models, namely a bias toward superficial sources (Fuchs et al., 1999).”
The time course of visual word recognition as revealed by linear regression analysis of ERP data
Hauk, O., Davis, M. H., Ford, M., Pulvermüller, F., & Marslen-Wilson, W. D. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.11.048 · Cited by 586
Lin, F.-H., Witzel, T., Ahlfors, S. P., Stufflebeam, S. M., Belliveau, J. W., & Hämäläinen, M. S. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.11.054 · Cited by 505
Triggering sleep slow waves by transcranial magnetic stimulation
Massimini, M., Ferrarelli, F., Esser, S. K., Riedner, B. A., Huber, R., Murphy, M., Peterson, M. J., & Tononi, G. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0702495104 · Cited by 489
Intracranial EEG Substrates of Scalp EEG Interictal Spikes
Tao, J. X., Ray, A., Hawes‐Ebersole, S., & Ebersole, J. S. (2005) · Epilepsia · doi:10.1111/j.1528-1167.2005.11404.x · Cited by 424
Neural Sources of Focused Attention in Visual Search
Hopf, J.-M. (2000) · Cerebral Cortex · doi:10.1093/cercor/10.12.1233 · Cited by 420
Epileptic source localization with high density EEG: how many electrodes are needed?
Lantz, G., Grave de Peralta, R., Spinelli, L., Seeck, M., & Michel, C. M. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00337-1 · Cited by 413
Decomposing EEG data into space–time–frequency components using Parallel Factor Analysis
Miwakeichi, F., Martı́nez-Montes, E., Valdés-Sosa, P. A., Nishiyama, N., Mizuhara, H., & Yamaguchi, Y. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.03.039 · Cited by 374
Electrical neuroimaging based on biophysical constraints
Grave de Peralta Menendez, R., Murray, M. M., Michel, C. M., Martuzzi, R., & Gonzalez Andino, S. L. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.09.051 · Cited by 365
A direct demonstration of cortical LTP in humans: A combined TMS/EEG study
Esser, S. K., Huber, R., Massimini, M., Peterson, M. J., Ferrarelli, F., & Tononi, G. (2006) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2005.11.003 · Cited by 361
Concurrent EEG/fMRI analysis by multiway Partial Least Squares
Martı́nez-Montes, E., Valdés-Sosa, P. A., Miwakeichi, F., Goldman, R. I., & Cohen, M. S. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.03.038 · Cited by 326
Hauk, O. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.12.018 · Cited by 300
Electrophysiological source imaging: A noninvasive window to brain dynamics
He, B., Sohrabpour, A., Brown, E., & Liu, Z. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-120853 · Cited by 297
Distributed current estimates using cortical orientation constraints
Lin, F., Belliveau, J. W., Dale, A. M., & Hämäläinen, M. S. (2006) · Human Brain Mapping · doi:10.1002/hbm.20155 · Cited by 289
Lemieux, L., Salek-Haddadi, A., Josephs, O., Allen, P., Toms, N., Scott, C., Krakow, K., Turner, R., & Fish, D. R. (2001) · NeuroImage · doi:10.1006/nimg.2001.0853 · Cited by 277
Movement related activity in the high gamma range of the human EEG
Ball, T., Demandt, E., Mutschler, I., Neitzel, E., Mehring, C., Vogt, K., Aertsen, A., & Schulze-Bonhage, A. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.02.032 · Cited by 274
Bayesian model averaging in EEG/MEG imaging
Trujillo-Barreto, N. J., Aubert-Vázquez, E., & Valdés-Sosa, P. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.11.008 · Cited by 262
Delayed Striate Cortical Activation during Spatial Attention
Noesselt, T., Hillyard, S. A., Woldorff, M. G., Schoenfeld, A., Hagner, T., Jäncke, L., Tempelmann, C., Hinrichs, H., & Heinze, H.-J. (2002) · Neuron · doi:10.1016/s0896-6273(02)00781-x · Cited by 262
Medial temporal theta state before an event predicts episodic encoding success in humans
Guderian, S., Schott, B. H., Richardson-Klavehn, A., & Düzel, E. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0900289106 · Cited by 260
EEG source localization in focal epilepsy: Where are we now?
Plummer, C., Harvey, A. S., & Cook, M. (2008) · Epilepsia · doi:10.1111/j.1528-1167.2007.01381.x · Cited by 252
Electric source imaging of human brain functions
Michel, C. M., Thut, G., Morand, S., Khateb, A., Pegna, A. J., Grave de Peralta, R., Gonzalez, S., Seeck, M., & Landis, T. (2001) · Brain Research Reviews · doi:10.1016/s0165-0173(01)00086-8 · Cited by 243
“response of single-trial event-related fMRI [40] solve this Distributed inverse solutions have been extensively tested problem only partially: covariance-based analysis of PET in many simulations and have been repeatedly applied to data cannot give information about the direction of activa- the localization of epilept…”
BackgroundVisual stimuli activate auditory cortex in deaf subjects: evidence from MEG
Finney, E. M., Clementz, B. A., Hickok, G., & Dobkins, K. R. (2003) · NeuroReport · doi:10.1097/00001756-200308060-00004 · Cited by 243
Worrell, G. A., Lagerlund, T. D., Sharbrough, F. W., Brinkmann, B. H., Busacker, N. E., Cicora, K. M., & O'Brien, T. J. (2000) · Brain Topography · doi:10.1023/a:1023407521772 · Cited by 242
Localizing Visual Discrimination Processes in Time and Space
Hopf, J.-M., Vogel, E., Woodman, G., Heinze, H.-J., & Luck, S. J. (2002) · Journal of Neurophysiology · doi:10.1152/jn.2002.88.4.2088 · Cited by 240
“A distributed source model (a model of the distribution of current over the cortical surface) served for source localization based on the minimum norm least-squares method (MNLS) (Fuchs et al. 1999).”
Functional coupling of simultaneous electrical and metabolic activity in the human brain
Oakes, T. R., Pizzagalli, D. A., Hendrick, A. M., Horras, K. A., Larson, C. L., Abercrombie, H. C., Schaefer, S. M., Koger, J. V., & Davidson, R. J. (2004) · Human Brain Mapping · doi:10.1002/hbm.20004 · Cited by 235
“Whereas some independent simulations [Fuchs et al., 1999] have suggested that the LORETA algorithm performs better than other linear algorithms (e.g., minimum norm least squares), others have raised considerable criticisms against it, particularly in cases of different sources with similar…”
MethodInfluentialEvaluation of EEG localization methods using realistic simulations of interictal spikes
Grova, C., Daunizeau, J., Lina, J.-M., Bénar, C. G., Benali, H., & Gotman, J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.053 · Cited by 233
Electroencephalography and High-Density Electrophysiological Source Localization
Pizzagalli, D. A. (2009) · Handbook of Psychophysiology · doi:10.1017/cbo9780511546396.003 · Cited by 226
Evaluation of sLORETA in the Presence of Noise and Multiple Sources
Wagner, M., Fuchs, M., & Kastner, J. (2004) · Brain Topography · doi:10.1023/b:brat.0000032865.58382.62 · Cited by 218
“For the one-dipole data with an SNR of 20, the methods behave as published previously (Pascual-Marqui 1994; Fuchs et al. 1999; Pascual-Marqui et al. 2002): LORETA computes blurred distributions whose maxima are close to the real source locations (figure 1, row 1), MNLS delivers source locations…”
BackgroundMethodSelf-citationThe advantage of combining MEG and EEG: Comparison to fMRI in focally stimulated visual cortex
Sharon, D., Hämäläinen, M. S., Tootell, R. B. H., Halgren, E., & Belliveau, J. W. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.03.066 · Cited by 215
“Anatomically constrained depth-weighted MNE inverse solution: To compensate for the inherent superficial bias of the MNE, depth-weighting has been suggested (Fuchs et al., 1999; Lin et al., 2006b).”
BackgroundHopf, J.-M., Boelmans, K., Schoenfeld, M. A., Luck, S. J., & Heinze, H.-J. (2004) · The Journal of Neuroscience · doi:10.1523/jneurosci.3564-03.2004 · Cited by 209
“…model ( CSF - layer BEM with 1510 Ϯ 147 nodes ) was used in conjunction with the observed ERMF response to estimate a model of the distribution of current over the cortical surface by means of the minimum norm least squares method ( L2 norm ) ( Ha - malainen and Ilmoniemi , 1994 ; Fuchs et al .”
MethodBarkley, G. L., & Baumgartner, C. (2003) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200305000-00002 · Cited by 202
“Thus, distributed source models could add additional information on the spatial distribution of the irritative zone (Fuchs et al., 1999; Michel et al., 1999).”
BackgroundInfluentialAttal, Y., & Schwartz, D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0059856 · Cited by 199
“To alleviate this problem, it is possible to apply depth weighting [18,19] to the MNE solution, obtaining a weighted minimum norm estimate (wMNE).”
MethodHauk, O., Wakeman, D. G., & Henson, R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.09.053 · Cited by 189
“Forward solutions for all sources in the model are normalized by a measure of their overall amplitude (e.g. a norm of the corresponding columns of the leadfield matrix) (e.g. Fuchs et al., 1999; Lin et al., 2006), which has been shown to improve localization error (Lin et al., 2006).”
InfluentialGenerators of the intracranial P50 response in auditory sensory gating
Korzyukov, O., Pflieger, M. E., Wagner, M., Bowyer, S. M., Rosburg, T., Sundaresan, K., Elger, C. E., & Boutros, N. N. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.12.011 · Cited by 183
“Using the method described by Fuchs et al. (1999), a current density regularization parameter lambda was optimized so that the residual deviation equaled 1/SNR (signal-to-noise ratio) for the latency yielding the highest SNR in the examined time range.”
Self-citation128-Channel EEG Source Imaging in Epilepsy: Clinical Yield and Localization Precision
Michel, C. M., Lantz, G., Spinelli, L., de Peralta, R. G., Landis, T., & Seeck, M. (2004) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200403000-00001 · Cited by 183
“Single-spike EEG source localization is principally feasible and can lead to fairly stable results if the signal-to-noise ratio is sufficient (Fuchs et al., 1999; Lantz et al., 1997a, 2001a, 2003a; Michel et al., 1999; Scherg et al., 1999).”
BackgroundElectromagnetic Inverse Solutions in Anatomically Constrained Spherical Head Models
Spinelli, L., Andino, S. G., Lantz, G., Seeck, M., & Michel, C. M. (2000) · Brain Topography · doi:10.1023/a:1026607118642 · Cited by 182
“Several solutions using other weighting strategies, regularizations and constraints have been suggested recently to ameliorate the depth precision of the solutions (e.g., Grave de Peralta and Gonzalez Andino 1998b; Fuchs et al. 1999).”
BackgroundMethodInfluentialSpectral spatiotemporal imaging of cortical oscillations and interactions in the human brain
Lin, F.-H., Witzel, T., Hämäläinen, M. S., Dale, A. M., Belliveau, J. W., & Stufflebeam, S. M. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.04.027 · Cited by 182
“Whereas Fuchs et al. (1999) suggest c = 0.”
BackgroundInfluentialswLORETA: a novel approach to robust source localization and synchronization tomography
Palmero-Soler, E., Dolan, K., Hadamschek, V., & Tass, P. A. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/7/002 · Cited by 175
Lantz, G., Spinelli, L., Seeck, M., de Peralta Menendez, R. G., Sottas, C. C., & Michel, C. M. (2003) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200309000-00003 · Cited by 170
“Intracranially verified propagation from the temporal tip to anterolateral temporal neocortex has been retrieved both with spatio-temporal dipole modeling (Scherg et al., 1999) and with a current density algorithm (Fuchs et al., 1999).”
BackgroundMethodHauk, O., Shtyrov, Y., & Pulvermüller, F. (2008) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2008.03.013 · Cited by 169
Feige, B., Aertsen, A., & Kristeva-Feige, R. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.5.2622 · Cited by 164
“Under these circumstances (sensor distribution, source model used, and color scale) the drop from 100 to 75% happens within a volume of 3 ϫ 3 ϫ 3 cm (Fuchs et al. 1999).”
MethodCaldara, R., Thut, G., Servoir, P., Michel, C. M., Bovet, P., & Renault, B. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00407-8 · Cited by 161
“A critical review of this solution is provided elsewhere (Fuchs et al., 1999; Michel et al., 1999a).”
RULLMANN, M., ANWANDER, A., DANNHAUER, M., WARFIELD, S., DUFFY, F., & WOLTERS, C. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.09.009 · Cited by 161
“It is well-known that a regularization without any depth-weighting gives preference to superficial sources (Pascual-Marqui and Michel, 1994; Fuchs et al., 1999).”
Iwasaki, M., Pestana, E., Burgess, R. C., Lüders, H. O., Shamoto, H., & Nakasato, N. (2005) · Epilepsia · doi:10.1111/j.0013-9580.2005.21104.x · Cited by 160
Hauck, M., Lorenz, J., & Engel, A. K. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.2283-07.2007 · Cited by 159
“Under these circumstances (sensor distribution, source model used, and color scale), the drop from 100 to 75% happens within a volume of 3 3 3 cm (Fuchs et al., 1999).”
MethodSparse source imaging in electroencephalography with accurate field modeling
Ding, L., & He, B. (2008) · Human Brain Mapping · doi:10.1002/hbm.20448 · Cited by 131
Integration of EEG/MEG with MRI and fMRI
Liu, Z., Ding, L., & He, B. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1657787 · Cited by 102
“The inverse problem then turns to retrieving the scalar distribution of dipole strength over the oriented cortical patches [11], [30]–[34].”
BackgroundAn alternative subspace approach to EEG dipole source localization
Xu, X.-L., Xu, B., & He, B. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/2/010 · Cited by 73
Kim, M., Cho, K. I. K., Yoon, Y. B., Lee, T. Y., & Kwon, J. S. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2016.11.027 · Cited by 30
Electrophysiological Mapping and Neuroimaging
He, B., & Ding, L. (2013) · Neural Engineering · doi:10.1007/978-1-4614-5227-0_12 · Cited by 26
Metadata
- Authors
- Fuchs, M., Wagner, M., Köhler, T., & Wischmann, H.-A.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 1999-05
- Volume
- 16
- Issue
- 3
- Pages
- 267-295
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2081465201
- Cited by
- 436
- References
- 28
- FWCI
- 10.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.