Influence of Proprioceptive Input on Parkinsonian Tremor
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Previous studies have shown a modification of parkinsonian tremor (PT) by proprioceptive input induced by passive joint movements. The authors investigated the impact of electrically evoked proprioceptive input on PT. In eight patients with PT they recorded surface EMG from the opponens pollicis muscle, and forearm extensors and flexors. Rhythmic electrical stimulation was applied to the ipsilateral median nerve at the wrist using a submaximal stimulus intensity and stimulus frequencies between two stimuli per second and five stimuli per second. The tremor frequency did not adapt to the stimulus frequency. Tremor frequency of parkinsonian resting tremor increased significantly in the directly stimulated opponens pollicis muscle (mean +/- standard deviation, 4.35 +/- 0.64 Hz without stimulation versus 4.53 +/- 0.68 Hz with stimulation; P < 0.05, paired t-test), the not directly stimulated forearm muscles (4.90 +/- 0.72 Hz versus 5.18 +/- 0.73 Hz, P < 0.001), and the upper arm muscles (5.13 +/- 0.61 Hz versus 5.36 +/- 0.68 Hz, P < 0.01). Furthermore, the parkinsonian postural tremor accelerated significantly during ipsilateral median nerve stimulation (5.31 +/- 0.99 Hz versus 5.44 +/- 1.03 Hz, P < 0.05). Parkinsonian resting tremor in the forearm muscles also accelerated significantly during ipsilateral ulnar nerve stimulation (4.85 +/- 0.57 Hz versus 5.05 +/- 0.65 Hz, P < 0.05). Contralateral median nerve stimulation had no significant effect. These results suggest a close interaction between proprioceptive input and PT generation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Consensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981
Lee, R. G., & Stein, R. B. (1981) · Annals of Neurology · doi:10.1002/ana.410100606 · Cited by 205
Cited by
Online tremor suppression using electromyography and low-level electrical stimulation
Dosen, S., Muceli, S., Dideriksen, J. L., Romero, J. P., Rocon, E., Pons, J., & Farina, D. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2328296 · Cited by 120
“Similarly, electrical stimulation delivered at the wrist joint to median and ulnar nerves modulated the tremor frequency [30].”
BackgroundPeripheral electrical stimulation to reduce pathological tremor: a review
Pascual-Valdunciel, A., Hoo, G. W., Avrillon, S., Barroso, F. O., Goldman, J. G., Hernandez-Pavon, J. C., & Pons, J. L. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00811-9 · Cited by 66
“[37], who tested at 2 Hz, 3 Hz, and 5 Hz, and Munhoz et al.”
BackgroundMethodInfluentialA Review on Wearable Technologies for Tremor Suppression
Lora-Millan, J. S., Delgado-Oleas, G., Benito-León, J., & Rocon, E. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.700600 · Cited by 62
“Similarly, low-level electrical stimulation applied at the wrist joint modulated the tremor frequency (105).”
BackgroundJitkritsadakul, O., Thanawattano, C., Anan, C., & Bhidayasiri, R. (2015) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2015.08.1527 · Cited by 38
Metadata
- Authors
- Spiegel, J., Fu, G., Krick, C., Schimrigk, K., & Dillmann, U.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 2002-01
- Volume
- 19
- Issue
- 1
- Pages
- 84-89
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2077007854
- Cited by
- 20
- References
- 2
- FWCI
- 0.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Influence of Proprioceptive Input on Parkinsonian Tremor. https://app.cochat.ai/papers/10.1097/00004691-200201000-00012
- The paper
- Spiegel, J., Fu, G., Krick, C., Schimrigk, K., & Dillmann, U. (2002). Influence of Proprioceptive Input on Parkinsonian Tremor. Journal of Clinical Neurophysiology. https://doi.org/10.1097/00004691-200201000-00012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.