Artifact Correction of the Ongoing EEG Using Spatial Filters Based on Artifact and Brain Signal Topographies
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Review and analysis of continuous EEG recordings may be impeded by physiological artifacts such as blinks, eye movements, or cardiac activity. Spatial filters based on artifact and brain signal topographies can remove artifacts completely without distortion of relevant brain activity. The authors describe the basic principle of artifact correction by spatial filtering and they review different approaches to estimate artifact and brain signal topographies. The main focus is on the preselection approach, which is fast enough to be applied while paging through the segments of a digital EEG recording. Examples of real EEG segments, containing epileptic seizure activity or interictal spikes contaminated by artifacts, show that spatial filtering by preselection can be a useful tool during EEG review. Advantages and disadvantages of the different spatial filter approaches are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Independent component analysis: algorithms and applications
Hyvärinen, A., & Oja, E. (2000) · Neural Networks · doi:10.1016/s0893-6080(00)00026-5 · Cited by 8,705
Golub, G. H., & Loan, C. F. V. (1996) · Johns Hopkins University Press eBooks · Cited by 6,027
Removing electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334
Spherical splines for scalp potential and current density mapping
Perrin, F., Pernier, J., Bertrand, O., & Echallier, J. F. (1989) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(89)90180-6 · Cited by 2,706 · cited 2×
“Spherical spline maps (Perrin et al. 1989) of the topography at the marked time points of blink and signal activity illustrate the spatial correlation.”
BackgroundIndependent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Blind signal separation: statistical principles
Cardoso, J.-F. (1998) · Proceedings of the IEEE · doi:10.1109/5.720250 · Cited by 1,885
Jung, T.-P., Makeig, S., Westerfield, M., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00386-2 · Cited by 1,322
Signal-space projection method for separating MEG or EEG into components
Uusitalo, M. A., & Ilmoniemi, R. J. (1997) · Medical & Biological Engineering & Computing · doi:10.1007/bf02534144 · Cited by 913
A multiple source approach to the correction of eye artifacts
Berg, P., & Scherg, M. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90094-9 · Cited by 696 · cited 2×
“For continuous data in the absence of suitable optimized dipole source models, Berg and Scherg (1991a, 1994) proposed “surrogate” MSEC.”
BackgroundMethodSelf-citationTwo bilateral sources of the late AEP as identified by a spatio-temporal dipole model
Scherg, M., & Von Cramon, D. (1985) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(85)90033-4 · Cited by 683
Self-citationExtraction of ocular artefacts from EEG using independent component analysis
Vigário, R. N. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00042-8 · Cited by 639
Extended ICA Removes Artifacts from Electroencephalographic Recordings
Jung, T., Humphries, C., Lee, T.-W., Makeig, S., McKeown, M. J., Iragui, V. J., & B, T. J. S. A. (1997) · Cited by 425
Lagerlund, T. D., Sharbrough, F. W., & Busacker, N. E. (1997) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199701000-00007 · Cited by 319
Independent Component Analysis for Identification of Artifacts in Magnetoencephalographic Recordings
Vigário, R., Jousmäki, V., Hämäläinen, M., Hari, R., & Erkki Oja, A. (1997) · neural information processing systems · Cited by 266
Scherg, M., Ille, N., Bornfleth, H., & Berg, P. (2002) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200203000-00001 · Cited by 208
Self-citationThe correction of ocular artifacts: a topographic perspective
Picton, T. W., van Roon, P., Armilio, M. L., Berg, P., Ille, N., & Scherg, M. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00227-8 · Cited by 205
Self-citationDipole models of eye movements and blinks
Berg, P., & Scherg, M. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90154-v · Cited by 200
Self-citationThe transfer of EOG activity into the EEG for eyes open and closed
Gasser, T., Sroka, L., & Möcks, J. (1985) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(85)91058-2 · Cited by 179
Berg, P., & Scherg, M. (1991) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/12/a/010 · Cited by 169
Self-citationEEG dipole modeling in complex partial epilepsy
Ebersole, J. S. (1991) · Brain Topography · doi:10.1007/bf01132768 · Cited by 132
Correcting ocular artifacts in the EEG: A comparison of several methods
BRUNIA, C. H. M., Möcks, J., & van den Berg-Lenssen, M. M. C. (1989) · Research portal (Tilburg University) · Cited by 86
Functional localization based on measurements with a whole-head magnetometer system
H�m�l�inen, M. S. (1995) · Brain Topography · doi:10.1007/bf01195254 · Cited by 66
Cardiac Artifacts in Magnetoencephalogram
Jousm??ki, V., & Hari, R. (1996) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199603000-00008 · Cited by 59
Blinks, Saccades, Extraocular Muscles and Visual Evoked Potentials (Reply to Verleger)
Picton, T. W., Roon, P. V., Armilio, M. L., Berg, P., Ille, N., & Scherg, M. (2000) · Journal of Psychophysiology · doi:10.1027//0269-8803.14.4.210 · Cited by 20
Self-citation
Cited by
EEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
Chaumon, M., Bishop, D. V. M., & Busch, N. A. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.02.025 · Cited by 833
Good practice for conducting and reporting MEG research
Gross, J., Baillet, S., Barnes, G. R., Henson, R. N., Hillebrand, A., Jensen, O., Jerbi, K., Litvak, V., Maess, B., Oostenveld, R., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.10.001 · Cited by 738
Prestimulus oscillations predict visual perception performance between and within subjects
Hanslmayr, S., Aslan, A., Staudigl, T., Klimesch, W., Herrmann, C. S., & Bäuml, K.-H. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.07.011 · Cited by 698
A brief introduction to the use of event-related potentials in studies of perception and attention
Woodman, G. F. (2010) · Attention Perception & Psychophysics · doi:10.3758/app.72.8.2031 · Cited by 632
Metadata
- Authors
- Ille, N., Berg, P., & Scherg, M.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 2002-03
- Volume
- 19
- Issue
- 2
- Pages
- 113-124
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2033632093
- Cited by
- 741
- References
- 24
- FWCI
- 3.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.