The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Independent Component Analysis as a Tool to Eliminate Artifacts in EEG: A Quantitative Study
Open accessAbstract
Independent component analysis (ICA) is a novel technique that calculates independent components from mixed signals. A hypothetical clinical application is to remove artifacts in EEG. The goal of this study was to apply ICA to standard EEG recordings to eliminate well-known artifacts, thus quantifying its efficacy in an objective way. Eighty samples of recordings with spikes and evident artifacts of electrocardiogram (EKG), eye movements, 50-Hz interference, muscle, or electrode artifact were studied. ICA components were calculated using the Joint Approximate Diagonalization of Eigen-matrices (JADE) algorithm. The signal was reconstructed excluding those components related to the artifacts. A normalized correlation coefficient was used as a measure of the changes caused by the suppression of these components. ICA produced an evident clearing-up of signals in all the samples. The morphology and the topography of the spike were very similar before and after the removal of the artifacts. The correlation coefficient showed that the rest of the signal did not change significantly. Two examiners independently looked at the samples to identify the changes in the morphology and location of the discharge and the artifacts. In conclusion, ICA proved to be a useful tool to clean artifacts in short EEG samples, without having the disadvantages associated with the digital filters. The distortion of the interictal activity measured by correlation analysis was minimal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Independent component analysis: algorithms and applications
Hyvärinen, A., & Oja, E. (2000) · Neural Networks · doi:10.1016/s0893-6080(00)00026-5 · Cited by 8,705
Independent Component Analysis
(2004) · Independent Component Analysis · doi:10.7551/mitpress/3717.003.0014 · Cited by 7,903
Removing electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334
Blind signal separation: statistical principles
Cardoso, J.-F. (1998) · Proceedings of the IEEE · doi:10.1109/5.720250 · Cited by 1,885
Jung, T.-P., Makeig, S., Westerfield, M., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00386-2 · Cited by 1,322
Independent component approach to the analysis of EEG and MEG recordings
Vigario, R., Sarela, J., Jousmiki, V., Hamalainen, M., & Oja, E. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.841330 · Cited by 796
Ille, N., Berg, P., & Scherg, M. (2002) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200203000-00002 · Cited by 741
Calhoun, V. D., Adali, T., Pearlson, G. D., & Pekar, J. J. (2001) · Human Brain Mapping · doi:10.1002/hbm.1024 · Cited by 697
Extraction of ocular artefacts from EEG using independent component analysis
Vigário, R. N. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00042-8 · Cited by 639
Fetal electrocardiogram extraction by blind source subspace separation
de Lathauwer, L., de Moor, B., & Vandewalle, J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.841326 · Cited by 502
Cited by
Delorme, A., Sejnowski, T., & Makeig, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.004 · Cited by 1,759
EEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
EMG and EOG artifacts in brain computer interface systems: A survey
Fatourechi, M., Bashashati, A., Ward, R. K., & Birch, G. E. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.10.019 · Cited by 638
Castellanos, N. P., & Makarov, V. A. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.05.033 · Cited by 569
Canonical Correlation Analysis Applied to Remove Muscle Artifacts From the Electroencephalogram
Clercq, W. D., Vergult, A., Vanrumste, B., Van Paesschen, W., & Van Huffel, S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.879459 · Cited by 522
Metadata
- Authors
- Iriarte, J., Urrestarazu, E., Valencia, M., Alegre, M., Malanda, A., Viteri, C., & Artieda, J.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 2003-07
- Volume
- 20
- Issue
- 4
- Pages
- 249-257
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2011957681
- Cited by
- 289
- References
- 26
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Independent Component Analysis as a Tool to Eliminate Artifacts in EEG: A Quantitative Study. https://app.cochat.ai/papers/10.1097/00004691-200307000-00004
- The paper
- Iriarte, J., Urrestarazu, E., Valencia, M., Alegre, M., Malanda, A., Viteri, C., & Artieda, J. (2003). Independent Component Analysis as a Tool to Eliminate Artifacts in EEG: A Quantitative Study. Journal of Clinical Neurophysiology. https://doi.org/10.1097/00004691-200307000-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.