The DOI matches its Crossref record.
Analysis of Emission Tomographic Scan Data: Limitations Imposed by Resolution and Background
Abstract
The proper analysis of positron emission tomographic scan data requires a careful knowledge of the limitations of the tomographic system used so that scan data can be collected and sampled in a manner consistent with those limitations. The present investigation was undertaken to clarify some of the limitations imposed by resolution. The usual imaging situation, e.g., 218FDG , C15O2, or 15O2 , involves imaging structures of limited size in all three dimensions which may appear either warm or cool in relation to some background level of activity. In emission tomography the importance of adequate data sampling within a given plane has been frequently emphasized. Little attention, however, has been given to proper z axis sampling for clinical scanning. The actual selection of regions of interest from scans can have a significant impact on the subsequent statistical analysis. Previous work on this subject has experimentally examined the relationship of object size to quantitative estimation in the hot spot-cold background situation for the one- and two-dimensional cases. Approximate three-dimensional recovery coefficients for the hot spot-cold background situation have been calculated. An examination of the factors discussed above, three-dimensional objects with varying contrast, z axis sampling, and selection of regions of interest, has not yet been addressed in the literature. The purpose of the present investigation is to examine these factors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Partial-Volume Effect in PET Tumor Imaging
Soret, M., Bacharach, S. L., & Buvat, I. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.035774 · Cited by 1,549
Müller-Gärtner, H. W., Links, J. M., Prince, J. L., Bryan, R. N., McVeigh, E., Leal, J. P., Davatzikos, C., & Frost, J. J. (1992) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1992.81 · Cited by 756
Erlandsson, K., Buvat, I., Pretorius, P. H., Thomas, B. A., & Hutton, B. F. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/21/r119 · Cited by 733
de la Fuente-Fernandez, R. (2004) · Brain · doi:10.1093/brain/awh290 · Cited by 402
Carson, R. E., Channing, M. A., Blasberg, R. G., Dunn, B. B., Cohen, R. M., Rice, K. C., & Herscovitch, P. (1993) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1993.6 · Cited by 375
Metadata
- Authors
- Kessler, R. M., Ellis, J. R., & Eden, M.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1984-06
- Volume
- 8
- Issue
- 3
- Pages
- 514-522
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2074210823
- Cited by
- 430
- References
- 0
- FWCI
- 4.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis of Emission Tomographic Scan Data: Limitations Imposed by Resolution and Background. https://app.cochat.ai/papers/10.1097/00004728-198406000-00028
- The paper
- Kessler, R. M., Ellis, J. R., & Eden, M. (1984). Analysis of Emission Tomographic Scan Data: Limitations Imposed by Resolution and Background. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-198406000-00028
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.