Analysis of Emission Tomographic Scan Data: Limitations Imposed by Resolution and Background
The DOI matches its Crossref record.
Abstract
The proper analysis of positron emission tomographic scan data requires a careful knowledge of the limitations of the tomographic system used so that scan data can be collected and sampled in a manner consistent with those limitations. The present investigation was undertaken to clarify some of the limitations imposed by resolution. The usual imaging situation, e.g., 218FDG , C15O2, or 15O2 , involves imaging structures of limited size in all three dimensions which may appear either warm or cool in relation to some background level of activity. In emission tomography the importance of adequate data sampling within a given plane has been frequently emphasized. Little attention, however, has been given to proper z axis sampling for clinical scanning. The actual selection of regions of interest from scans can have a significant impact on the subsequent statistical analysis. Previous work on this subject has experimentally examined the relationship of object size to quantitative estimation in the hot spot-cold background situation for the one- and two-dimensional cases. Approximate three-dimensional recovery coefficients for the hot spot-cold background situation have been calculated. An examination of the factors discussed above, three-dimensional objects with varying contrast, z axis sampling, and selection of regions of interest, has not yet been addressed in the literature. The purpose of the present investigation is to examine these factors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Partial-Volume Effect in PET Tumor Imaging
Soret, M., Bacharach, S. L., & Buvat, I. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.035774 · Cited by 1,549
Müller-Gärtner, H. W., Links, J. M., Prince, J. L., Bryan, R. N., McVeigh, E., Leal, J. P., Davatzikos, C., & Frost, J. J. (1992) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1992.81 · Cited by 756
Erlandsson, K., Buvat, I., Pretorius, P. H., Thomas, B. A., & Hutton, B. F. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/21/r119 · Cited by 733
de la Fuente-Fernandez, R. (2004) · Brain · doi:10.1093/brain/awh290 · Cited by 402
Carson, R. E., Channing, M. A., Blasberg, R. G., Dunn, B. B., Cohen, R. M., Rice, K. C., & Herscovitch, P. (1993) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1993.6 · Cited by 375
Resolution modeling in PET imaging: Theory, practice, benefits, and pitfalls
Rahmim, A., Qi, J., & Sossi, V. (2013) · Medical Physics · doi:10.1118/1.4800806 · Cited by 357
Staging non—small cell lung cancer by whole-body positron emission tomographic imaging
Valk, P. E., Pounds, T. R., Hopkins, D. M., Haseman, M. K., Hofer, G. A., Greiss, H. B., Myers, R. W., & Lutrin, C. L. (1995) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(95)00752-0 · Cited by 316
MRI-PET Correlation in Three Dimensions Using a Volume-of-Interest (VOI) Atlas
Evans, A. C., Marrett, S., Torrescorzo, J., Ku, S., & Collins, L. (1991) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1991.40 · Cited by 264
Hoekstra, C. J., Paglianiti, I., Hoekstra, O. S., Smit, E. F., Postmus, P. E., Teule, G. J. J., & Lammertsma, A. A. (2000) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050570 · Cited by 251
“This will improve image contrast and give a direct view of glucose consumption, facilitating the definition of ROI [ 90 ].”
BackgroundZald, D. H., Cowan, R. L., Riccardi, P., Baldwin, R. M., Ansari, M. S., Li, R., Shelby, E. S., Smith, C. E., McHugo, M., & Kessler, R. M. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.2423-08.2008 · Cited by 234
“This resolution allows visualization of [ 18F]fallypride BPND in the substantia nigra (SN)/ ventral tegmental area (VTA) [see Kessler et al. (1984), for a discussion of the spatial resolution requirements for detecting activity in the SN].”
MethodSelf-citationEvans, A. C., Beil, C., Marrett, S., Thompson, C. J., & Hakim, A. (1988) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1988.92 · Cited by 232
Gear, J. I., Cox, M. G., Gustafsson, J., Gleisner, K. S., Murray, I., Glatting, G., Konijnenberg, M., & Flux, G. D. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4136-7 · Cited by 229
Statistical approaches in quantitative positron emission tomography
Leahy, R. M., & Qi, J. (2000) · Statistics and Computing · doi:10.1023/a:1008946426658 · Cited by 215
Absolute quantification in SPECT
Ritt, P., Vija, H., Hornegger, J., & Kuwert, T. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1770-8 · Cited by 213
“This process is compromised by photon scatter [3–5], photon attenuation [6–9], and partial volume artefacts [10, 11].”
BackgroundPöttgen, C., Levegrün, S., Theegarten, D., Marnitz, S., Grehl, S., Pink, R., Eberhardt, W., Stamatis, G., Gauler, T., Antoch, G., et al. (2006) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-05-0510 · Cited by 204
Seo, Y., Mari, C., & Hasegawa, B. H. (2008) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2008.01.001 · Cited by 198
“In addition, the quantitative accuracy of SPECT can be compromised by partial-volume errors [93].”
BackgroundAn outlook on future design of hybrid PET/MRI systems: Design of hybrid PET/MRI scanners
Zaidi, H., & Del Guerra, A. (2011) · Medical Physics · doi:10.1118/1.3633909 · Cited by 193
Partial Volume Correction Strategies in PET
Rousset, O., Rahmim, A., Alavi, A., & Zaidi, H. (2007) · PET Clinics · doi:10.1016/j.cpet.2007.10.005 · Cited by 190
“The concept of contrast recovery coefficient, introduced by Kessler and colleagues [15], reflects the rate of recovery that lies above”
BackgroundGonzalez-Escamilla, G., Lange, C., Teipel, S., Buchert, R., & Grothe, M. J. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.077 · Cited by 186
“The situation is different for effects related to limited spatial resolution of PET imaging, usually referred to as partial volume effects (Erlandsson et al., 2012; Kessler et al., 1984).”
BackgroundEvaluation of Pulmonary Lesions With FDG-PET
Knight, S. B., Delbeke, D., Stewart, J. R., & Sandler, M. P. (1996) · Chest · doi:10.1378/chest.109.4.982 · Cited by 182
Dopa decarboxylase activity of the living human brain.
Gjedde, A., Reith, J., Dyve, S., Léger, G., Guttman, M., Diksic, M., Evans, A., & Kuwabara, H. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.7.2721 · Cited by 170
Blankespoor, S. C., Xu, X., Kaiki, K., Brown, J. K., Tang, H. R., Cann, C. E., & Hasegawa, B. H. (1996) · IEEE Transactions on Nuclear Science · doi:10.1109/23.531891 · Cited by 170
A theoretical study of the contrast recovery and variance of MAP reconstructions from PET data
Qi, J., & Leahy, R. M. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.768839 · Cited by 167
“CRC [28] crc as a measure of resolution where”
BackgroundLee, J. A. (2010) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2010.07.003 · Cited by 159
“Several publications have pursued this line of investigation, in both SPECT [60,61] and PET [46] literatures.”
BackgroundKessler, R. M., Woodward, N. D., Riccardi, P., Li, R., Ansari, M. S., Anderson, S., Dawant, B., Zald, D., & Meltzer, H. Y. (2009) · Biological Psychiatry · doi:10.1016/j.biopsych.2008.12.029 · Cited by 136
“While the PET scanner used in this study does not have sufficient resolution to provide complete quantitative recovery of DA D2r levels in the substantia nigra, published calculated estimates of quantitative recovery for the substantia nigra indicate that the the 5-6 mm resolution of the scanner does allow substantial…”
Self-citationZaidi, H., Ruest, T., Schoenahl, F., & Montandon, M.-L. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.05.031 · Cited by 108
“This includes pioneering research attempting some sort of PVC through the application of recovery coefficients described in the reference above as well as those derived from Kessler’s formulation (Kessler et al., 1984).”
MethodPET quantification: strategies for partial volume correction
Bettinardi, V., Castiglioni, I., De Bernardi, E., & Gilardi, M. C. (2014) · Clinical and Translational Imaging · doi:10.1007/s40336-014-0066-y · Cited by 105
“These are generally spherical objects of known diameter, filled with a known radioactivity concentration that are then placed in a cold background [19–21].”
BackgroundPretorius, P. H., King, M. A., Pan, T.-S., Vries, D. J. D., Glick, S. J., & Byrne, C. L. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/2/014 · Cited by 72
A method for model-free partial volume correction in oncological PET
Hofheinz, F., Langner, J., Petr, J., Beuthien-Baumann, B., Oehme, L., Steinbach, J., Kotzerke, J., & van den Hoff, J. (2012) · EJNMMI Research · doi:10.1186/2191-219x-2-16 · Cited by 55
“While SUVmax is affected only for small structures (whose size is comparable to – or smaller than – the given spatial resolution), SUVmean is compromised even at target sizes much larger than the reconstructed spatial resolution [4,5].”
Background
Metadata
- Authors
- Kessler, R. M., Ellis, J. R., & Eden, M.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1984-06
- Volume
- 8
- Issue
- 3
- Pages
- 514-522
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2074210823
- Cited by
- 430
- References
- 0
- FWCI
- 4.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.