In Vivo Validation of MR Velocity Imaging
The DOI matches its Crossref record.
Abstract
Calculations of left ventricular stroke volume obtained by summing the areas of multiple contiguous transverse magnetic resonance (MR) slices in systole and diastole using a spin echo sequence have been compared in 10 healthy volunteers with the stroke output derived from velocity maps in the ascending aorta using a field even-echo rephasing sequence. The results gave a correlation coefficient of 0.97 (p less than 0.001) and a standard error of estimate of 3.2 ml. Velocity maps have also been obtained in the pulmonary artery, the descending aorta, and the superior vena cava. The accuracy of this technique and the theoretical limitations of MR measurements have implications for the earlier detection of atheroma in the coronary and other arteries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
4D flow cardiovascular magnetic resonance consensus statement
Dyverfeldt, P., Bissell, M., Barker, A. J., Bolger, A. F., Carlhäll, C.-J., Ebbers, T., Francios, C. J., Frydrychowicz, A., Geiger, J., Giese, D., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0174-5 · Cited by 877
Grothues, F., Moon, J. C., Bellenger, N. G., Smith, G. S., Klein, H. U., & Pennell, D. J. (2004) · American Heart Journal · doi:10.1016/j.ahj.2003.10.005 · Cited by 776
Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report?
PENNELL, D. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.040 · Cited by 747
Asymmetric redirection of flow through the heart
Kilner, P. J., Yang, G.-Z., Wilkes, A. J., Mohiaddin, R. H., Firmin, D. N., & Yacoub, M. H. (2000) · Nature · doi:10.1038/35008075 · Cited by 715
Self-citationMOOREJR, J., XU, C., GLAGOV, S., ZARINS, C., & KU, D. (1994) · Atherosclerosis · doi:10.1016/0021-9150(94)90207-0 · Cited by 425
Beerbaum, P., Körperich, H., Barth, P., Esdorn, H., Gieseke, J., & Meyer, H. (2001) · Circulation · doi:10.1161/01.cir.103.20.2476 · Cited by 309
Hunter, P. J., Pullan, A. J., & Smaill, B. H. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121537 · Cited by 291
Stanković, Z. B., Allen, B. D., García, J., Jarvis, K., & Markl, M. (2014) · PubMed · doi:10.3978/j.issn.2223-3652.2014.01.02 · Cited by 281
Kim, W. Y., Walker, P. G., Pedersen, E. M., Poulsen, J. K., Oyre, S., Houlind, K., & Yoganathan, A. P. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00141-l · Cited by 274
Clinical Indications for Cardiovascular Magnetic Resonance (CMR): Consensus Panel Report #
Pennell, D., Sechtem, U., Higgins, C., Manning, W., Pohost, G., Rademakers, F., van Rossum, A., Shaw, L., & Kent Yucel, E. (2004) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-200038581 · Cited by 274
Cardiovascular magnetic resonance phase contrast imaging
Nayak, K. S., Nielsen, J.-F., Bernstein, M. A., Markl, M., D. Gatehouse, P., M. Botnar, R., Saloner, D., Lorenz, C., Wen, H., S. Hu, B., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0172-7 · Cited by 264
Cardiac MR Imaging: State of the Technology
Finn, J. P., Nael, K., Deshpande, V., Ratib, O., & Laub, G. (2006) · Radiology · doi:10.1148/radiol.2412041866 · Cited by 215
Powell, A. J., Maier, S. E., Chung, T., & Geva, T. (2000) · Pediatric Cardiology · doi:10.1007/s002469910014 · Cited by 207
“Several authors demonstrated close agreement between ventricular stroke volume obtained by PVC MRI and that obtained by subtracting end systolic volume from end diastolic volume [4, 11, 20, 28, 34].”
BackgroundQuantification of mitral regurgitation by velocity-encoded cine nuclear magnetic resonance imaging
Fujita, N., Chazouilleres, A. F., Hartiala, J. J., O'sullivan, M., Heidenreich, P., Kaplan, J. D., Sakuma, H., Foster, E., Caputo, G. R., & Higgins, C. B. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90642-4 · Cited by 198
van der Geest, R. J., & Reiber, J. H. C. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199911)10:5<602::aid-jmri3>3.0.co;2-c · Cited by 183
“The clinical value of VEC-MRI has been proved in the evaluation of flow in the greater arteries (15,16), atrioventricular valve planes (13), coronary arteries (17), and bypass grafts (18).”
BackgroundDetermination of wall shear stress in the aorta with the use of MR phase velocity mapping
Osinnski, J. N., Ku, D. N., Mukundan, S., Loth, F., & Pettigrew, R. I. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050605 · Cited by 174
Muthurangu, V., Taylor, A., Andriantsimiavona, R., Hegde, S., Miquel, M. E., Tulloh, R., Baker, E., Hill, D. L. G., & Razavi, R. S. (2004) · Circulation · doi:10.1161/01.cir.0000138741.72946.84 · Cited by 165
Quantitation of cardiac output with velocity-encoded, phase-difference magnetic resonance imaging
Hundley, W. G., Li, H. F., Hillis, L. D., Meshack, B. M., Lange, R. A., Willard, J. E., Landau, C., & Peshock, R. M. (1995) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)80772-3 · Cited by 163
Assessment of Coronary Arterial Flow and Flow Reserve in Humans With Magnetic Resonance Imaging
Hundley, W. G., Lange, R. A., Clarke, G. D., Meshack, B. M., Payne, J., Landau, C., McColl, R., Sayad, D. E., Willett, D. L., Willard, J. E., et al. (1996) · Circulation · doi:10.1161/01.cir.93.8.1502 · Cited by 161
Cardiac MR Imaging Assessment Following Tetralogy of Fallot Repair
Norton, K. I., Tong, C., Glass, R. B. J., & Nielsen, J. C. (2006) · RadioGraphics · doi:10.1148/rg.261055064 · Cited by 67
Metadata
- Authors
- Firmin, D. N., Nayler, G. L., Klipstein, R. H., Underwood, S. R., Rees, R. S. O., & Longmore, D. B.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1987-09
- Volume
- 11
- Issue
- 5
- Pages
- 751-756
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2089775122
- Cited by
- 332
- References
- 0
- FWCI
- 5.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.