Accuracy and Reproducibility in Volumetric Analysis of Multiple Sclerosis Lesions
The DOI matches its Crossref record.
Abstract
The accuracy and reproducibility of dual-contrast segmentation based on nonparametric feature map analysis have been investigated in a multicomponent gelatin phantom. The root mean square errors in volume ranged from 0.02 cm3 for small volumes to 3.8 cm3 for larger volumes, with a mean error of 0.97 cm3. Average inter- and intraobserver coefficients of variation were found to be < 7% for all compartments. To evaluate the reproducibility of segmentation of clinical image data, volumes of total brain, CSF, and multiple sclerosis (MS) lesions were obtained from five image sets of MS patients. Inter- and intraobserver coefficients of variations were computed for the patient data and were found to be < 5% for brain, 17% for CSF, and 20% for MS lesions. Such variations were found to be reduced by appropriate preprocessing of the images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Morphometric analysis of white matter lesions in MR images: method and validation
Zijdenbos, A. P., Dawant, B. M., Margolin, R. A., & Palmer, A. C. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363096 · Cited by 1,265
MRI segmentation: Methods and applications
Clarke, L. P., Velthuizen, R. P., Camacho, M. A., Heine, J. J., Vaidyanathan, M., Hall, L. O., Thatcher, R. W., & Silbiger, M. L. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)00124-l · Cited by 695
Miller, D. H., Albert, P. S., Barkhof, F., Francis, G., Frank, J. A., Hodgkinson, S., Lublin, F. D., Paty, D. W., Reingold, S. C., & Simon, J. (1996) · Annals of Neurology · doi:10.1002/ana.410390104 · Cited by 444
Multiple sclerosis lesion quantification using fuzzy-connectedness principles
Udupa, J. K., Wei, L., Samarasekera, S., Miki, Y., van Buchem, M. A., & Grossman, R. I. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.640750 · Cited by 314
Information theoretic clustering
Gokcay, E., & Principe, J. C. (2002) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.982897 · Cited by 293
Reddick, W. E., Glass, J. O., Cook, E. N., Elkin, T. D., & Deaton, R. J. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.650887 · Cited by 290
Self-organizing map and clustering for wastewater treatment monitoring
López Garcı́a, H., & Machón González, I. (2004) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2004.03.004 · Cited by 211
FLAIR histogram segmentation for measurement of leukoaraiosis volume
Jack, C. R., O'Brien, P. C., Rettman, D. W., Shiung, M. M., Xu, Y., Muthupillai, R., Manduca, A., Avula, R., & Erickson, B. J. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10011 · Cited by 176
Hippocampal volume assessment in temporal lobe epilepsy: How good is automated segmentation?
Pardoe, H. R., Pell, G. S., Abbott, D. F., & Jackson, G. D. (2009) · Epilepsia · doi:10.1111/j.1528-1167.2009.02243.x · Cited by 164
“…changes associated with mTLE have been well characterized in numerous previous studies (Jack et al., 1990; Cook et al., 1992; Cendes et al., 1993a; Jackson et al., 1993; Van Paesschen et al., 1995; Marsh et al., 1997; Kuzniecky, 1998; Mackay et al., 2000; Keller et al., 2002; Bernasconi et al.,…”
BackgroundMethodMoore, B. D., Slopis, J. M., Schomer, D., Jackson, E. F., & Levy, B. M. (1996) · Neurology · doi:10.1212/wnl.46.6.1660 · Cited by 151
Self-citation
Metadata
- Authors
- Jackson, E. F., Narayana, P. A., Wolinsky, J. S., & Doyle, T. J.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1993-03
- Volume
- 17
- Issue
- 2
- Pages
- 200-205
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2050731694
- Cited by
- 79
- References
- 0
- FWCI
- 12.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.