A Fully Automatic Multimodality Image Registration Algorithm
The DOI matches its Crossref record.
Abstract
OBJECTIVE: A fully automatic multimodality image registration algorithm is presented. The method is primarily designed for 3D registration of MR and PET images of the brain. However, it has also been successfully applied to CT-PET, MR-CT, and MR-SPECT registrations. MATERIALS AND METHODS: The head contour is detected on the MR image using a gradient threshold method. The head region in the MR image is then segmented into a set of connected components using the K-means clustering algorithm. When the two image sets are registered, the segmentation of the MR image indirectly generates a segmentation of the PET image. The best registration is taken to be the one that optimizes the segmentation induced on the PET image. In this article, the K-means minimum variance criterion is used as a cost function, and the optimization is performed using the method of coordinate descent. RESULTS: The algorithm was tested on 80 H2 15O PET and MR image pairs from 10 subjects. Qualitatively correct results were obtained in all cases. With use of external markers visible in both image modalities, the average registration error was estimated to be < 3 mm. CONCLUSION: The algorithm presented in this article requires no user interaction and can be applied to a wide range of registration problems. Quantitative and qualitative evaluations of the algorithm indicate a high degree of accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A survey of medical image registration
Maintz, J. B. A., & Viergever, M. A. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80026-8 · Cited by 3,327
Evaluation of 14 nonlinear deformation algorithms applied to human brain MRI registration
Klein, A., Andersson, J., Ardekani, B. A., Ashburner, J., Avants, B., Chiang, M.-C., Christensen, G. E., Collins, D. L., Gee, J., Hellier, P., et al. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.037 · Cited by 2,227
Self-citationDiffeomorphic registration using geodesic shooting and Gauss–Newton optimisation
Ashburner, J., & Friston, K. J. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.12.049 · Cited by 503
Image guidance for precise conformal radiotherapy
Mackie, T. R., Kapatoes, J., Ruchala, K., Lu, W., Wu, C., Olivera, G., Forrest, L., Tome, W., Welsh, J., Jeraj, R., et al. (2003) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(03)00090-7 · Cited by 484
Kaisti, K. K., Långsjö, J. W., Aalto, S., Oikonen, V., Sipilä, H., Teräs, M., Hinkka, S., Metsähonkala, L., & Scheinin, H. (2003) · Anesthesiology · doi:10.1097/00000542-200309000-00015 · Cited by 428
Update on Bispectral Index monitoring
Johansen, J. W. (2006) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2005.08.004 · Cited by 313
Microstructural White Matter Abnormalities and Remission of Geriatric Depression
Alexopoulos, G. S., Murphy, C. F., Gunning-Dixon, F. M., Latoussakis, V., Kanellopoulos, D., Klimstra, S., Lim, K. O., & Hoptman, M. J. (2008) · American Journal of Psychiatry · doi:10.1176/appi.ajp.2007.07050744 · Cited by 299
Attention-deficit/hyperactivity disorder: a preliminary diffusion tensor imaging study
Ashtari, M., Kumra, S., Bhaskar, S. L., Clarke, T., Thaden, E., Cervellione, K. L., Rhinewine, J., Kane, J. M., Adesman, A., Milanaik, R., et al. (2005) · Biological Psychiatry · doi:10.1016/j.biopsych.2004.11.047 · Cited by 295
Self-citationLipton, M. L., Gulko, E., Zimmerman, M. E., Friedman, B. W., Kim, M., Gellella, E., Gold, T., Shifteh, K., Ardekani, B. A., & Branch, C. A. (2009) · Radiology · doi:10.1148/radiol.2523081584 · Cited by 290
Self-citationKaisti, K. K., Metsähonkala, L., Teräs, M., Oikonen, V., Aalto, S., Jääskeläinen, S., Hinkka, S., & Scheinin, H. (2002) · Anesthesiology · doi:10.1097/00000542-200206000-00015 · Cited by 276
Romero, L. M., & Remage-Healey, L. (2000) · General and Comparative Endocrinology · doi:10.1006/gcen.2000.7491 · Cited by 259
Evaluation of volume-based and surface-based brain image registration methods
Klein, A., Ghosh, S. S., Avants, B., Yeo, B. T. T., Fischl, B., Ardekani, B., Gee, J. C., Mann, J. J., & Parsey, R. V. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.01.091 · Cited by 255
Self-citationMRI study of white matter diffusion anisotropy in schizophrenia
Ardekani, B. A., Nierenberg, J., Hoptman, M. J., Javitt, D. C., & Lim, K. O. (2003) · NeuroReport · doi:10.1097/00001756-200311140-00004 · Cited by 244
Self-citationArdekani, B. A., Guckemus, S., Bachman, A., Hoptman, M. J., Wojtaszek, M., & Nierenberg, J. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.07.014 · Cited by 243
“In ART, there is an option for performing an initial rigid-body registration using the method described by Ardekani et al. (1995).”
MethodSelf-citationSzeszko, P. R., Robinson, D. G., Ashtari, M., Vogel, J., Betensky, J., Sevy, S., Ardekani, B. A., Lencz, T., Malhotra, A. K., McCormack, J., et al. (2008) · Neuropsychopharmacology · doi:10.1038/sj.npp.1301480 · Cited by 242
“For all individuals the cropped SPGR volume was registered to their fast spin echo T2/PD volumes (Ardekani et al, 1995) yielding a resliced SPGR volume with the same orientation and voxel size as the T2/PD volumes.”
MethodSelf-citationFunctional Identification of the Primary Motor Area by Corticospinal Tractography
Kamada, K., Sawamura, Y., Takeuchi, F., Kawaguchi, H., Kuriki, S., Todo, T., Morita, A., Masutani, Y., Aoki, S., & Kirino, T. (2005) · Operative Neurosurgery · doi:10.1227/01.neu.0000144311.88383.ef · Cited by 241
“Within each defined cluster on the functional data sets, the algorithm iteratively updated the registration parameters using affine transformation to minimize results of the cost function, which evaluated the spatial difference between anatomic and functional data sets (2).”
MethodLipton, M. L., Gellella, E., Lo, C., Gold, T., Ardekani, B. A., Shifteh, K., Bello, J. A., & Branch, C. A. (2008) · Journal of Neurotrauma · doi:10.1089/neu.2008.0547 · Cited by 239
“• Registration to standard space: The 3D nonlinear registration module of ART registered each subject's 3D FSPGR volume to a standard T1-weighted template (Montreal Neurological Institute [MNI] atlas).”
MethodInfluentialSelf-citationWhite Matter Abnormalities in Obsessive-compulsive Disorder: A Diffusion Tensor Imaging Study
Szeszko, P. R., Ardekani, B. A., Ashtari, M., Malhotra, A. K., Robinson, D. G., Bilder, R. M., & Lim, K. O. (2005) · Archives of General Psychiatry · doi:10.1001/archpsyc.62.7.782 · Cited by 235
“Second, for each subject, the cropped SPGR volume was registered to their fast spin echo T2/PD volumes.(47) This yielded a resliced SPGR volume with the same orientation and voxel size as the T2/PD volumes.”
MethodSelf-citationGhahremani, D. G., Lee, B., Robertson, C. L., Tabibnia, G., Morgan, A. T., De Shetler, N., Brown, A. K., Monterosso, J. R., Aron, A. R., Mandelkern, M. A., et al. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.4284-11.2012 · Cited by 227
“After motion correction, PET images were coregistered to the participant’s structural MRI using a six-parameter, rigid-body transformation computed with the ART software package (Ardekani et al., 1995).”
Effect of Nitrous Oxide on Excitatory and Inhibitory Synaptic Transmission in Hippocampal Cultures
Mennerick, S., Jevtovic-Todorovic, V., Todorovic, S. M., Shen, W., Olney, J. W., & Zorumski, C. F. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-23-09716.1998 · Cited by 224
Ashtari, M., Cervellione, K. L., Hasan, K. M., Wu, J., McIlree, C., Kester, H., Ardekani, B. A., Roofeh, D., Szeszko, P. R., & Kumra, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.10.047 · Cited by 223
Self-citationSzeszko, P. R., Ardekani, B. A., Ashtari, M., Kumra, S., Robinson, D. G., Sevy, S., Gunduz-Bruce, H., Malhotra, A. K., Kane, J. M., Bilder, R. M., et al. (2005) · American Journal of Psychiatry · doi:10.1176/appi.ajp.162.3.602 · Cited by 191
“Second, the T2- and proton density-weighted volumes were registered to the spoiled-gradient recall acquisition volume within each subject (29).”
BackgroundSelf-citationPET: Physics, Instrumentation, and Scanners
Cherry, S. R., & Dahlbom, M. (2006) · PET · doi:10.1007/0-387-34946-4_1 · Cited by 181
Larsen, B., Seitz, A., & Larsen, R. (2000) · Anesthesia & Analgesia · doi:10.1097/00000539-200001000-00035 · Cited by 173
Preliminary evidence for brain complications in obese adolescents with type 2 diabetes mellitus
Yau, P. L., Javier, D. C., Ryan, C. M., Tsui, W. H., Ardekani, B. A., Ten, S., & Convit, A. (2010) · Diabetologia · doi:10.1007/s00125-010-1857-y · Cited by 168
“DTI image processing To create the group maps for voxelwise group comparisons a three-step approach was used to correct the images for echo planar acquisition distortions after optimising registration between the T2 and MPRAGE images [32].”
Self-citationA DTI study of white matter microstructure in individuals at high genetic risk for schizophrenia
HOPTMAN, M., NIERENBERG, J., BERTISCH, H., CATALANO, D., ARDEKANI, B., BRANCH, C., & DELISI, L. (2008) · Schizophrenia Research · doi:10.1016/j.schres.2008.07.023 · Cited by 143
“Next, the b=0 images were matched to the raw T2 weighted images and were corrected for distortion using ART.”
InfluentialSelf-citationHatazawa, J., Shimosegawa, E., Satoh, T., Toyoshima, H., & Okudera, T. (1997) · Stroke · doi:10.1161/01.str.28.10.1944 · Cited by 94
Metadata
- Authors
- Ardekani, B. A., Braun, M., Hutton, B. F., Kanno, I., & Iida, H.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1995-07
- Volume
- 19
- Issue
- 4
- Pages
- 615-623
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2040212643
- Cited by
- 310
- References
- 0
- FWCI
- 11.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.