Detection of Subtle Brain Changes Using Subvoxel Registration and Subtraction of Serial MR Images
The DOI matches its Crossref record.
Abstract
OBJECTIVE: The aim of this study was to examine the potential of accurate image registration for detecting subtle changes in the brain. MATERIALS AND METHODS: Isotropic T1-weighted volume images were obtained in 10 normal subjects and five patients on two or more occasions (including pre- and postcontrast studies). The images were segmented and a 3D rigid body translation and rotation technique was used with sinc interpolation to precisely match the images using a chi 2-test. The registered images and the subtraction images produced from them were used to detect changes in signal intensity, sit, shape, and size of the brain. RESULTS: Small changes due to differences in orientation of the head, growth, and development as well as inhalation of oxygen and carbogen (95% O2/5% CO2) were observed in normal subjects. Changes were also observed in patients with minor head trauma, a meningioma, an astrocytoma, and multiple sclerosis. Differences due to contrast enhancement and surgery and/or anesthesia were also seen. CONCLUSION: With use of subvoxel registration, subtle changes in the brain were detected in a variety of physiological and clinical situations where differences have hitherto been difficult or impossible to detect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Jenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888
A survey of medical image registration
Maintz, J. B. A., & Viergever, M. A. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80026-8 · Cited by 3,327
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
Accurate, Robust, and Automated Longitudinal and Cross-Sectional Brain Change Analysis
Smith, S. M., Zhang, Y., Jenkinson, M., Chen, J., Matthews, P. M., Federico, A., & De Stefano, N. (2002) · NeuroImage · doi:10.1006/nimg.2002.1040 · Cited by 2,013
Automated Image Registration: I. General Methods and Intrasubject, Intramodality Validation
Woods, R. P., Grafton, S. T., Holmes, C. J., Cherry, S. R., & Mazziotta, J. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199801000-00027 · Cited by 1,707
In-vivo measurement of activated microglia in dementia
Cagnin, A., Brooks, D. J., Kennedy, A. M., Gunn, R. N., Myers, R., Turkheimer, F. E., Jones, T., & Banati, R. B. (2001) · The Lancet · doi:10.1016/s0140-6736(01)05625-2 · Cited by 1,054
Newlands, E. S., Stevens, M. F. G., Wedge, S. R., Wheelhouse, R. T., & Brock, C. (1997) · Cancer Treatment Reviews · doi:10.1016/s0305-7372(97)90019-0 · Cited by 817
Medical image registration: a review
Oliveira, F. P. M., & Tavares, J. M. R. S. (2014) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2012.670855 · Cited by 737
Normalized Accurate Measurement of Longitudinal Brain Change
Smith, S. M., De Stefano, N., Jenkinson, M., & Matthews, P. M. (2001) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200105000-00022 · Cited by 488
Systematic meta-review and quality assessment of the structural brain alterations in schizophrenia
Shepherd, A. M., Laurens, K. R., Matheson, S. L., Carr, V. J., & Green, M. J. (2012) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2011.12.015 · Cited by 412
Freeborough, P. A., & Fox, N. C. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.640753 · Cited by 382
Visualisation and quantification of rates of atrophy in Alzheimer's disease
Fox, N. C., Freeborough, P. A., & Rossor, M. N. (1996) · The Lancet · doi:10.1016/s0140-6736(96)05228-2 · Cited by 378
Fox, N. C., & Freeborough, P. A. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070620 · Cited by 325
Voxel similarity measures for 3-D serial MR brain image registration
Holden, M., Hill, D. L. G., Denton, E. R. E., Jarosz, J. M., Cox, T. C. S., Rohlfing, T., Goodey, J., & Hawkes, D. J. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.836369 · Cited by 277
Weinberger, D. R., & McClure, R. K. (2002) · Archives of General Psychiatry · doi:10.1001/archpsyc.59.6.553 · Cited by 260
The benefit of stereology for quantitative radiology.
Roberts, N., Puddephat, M. J., & McNulty, V (2000) · The British Journal of Radiology · doi:10.1259/bjr.73.871.11089458 · Cited by 248
Voxel Similarity Measures for 3D Serial MR Brain Image Registration
Holden, M., Hill, D. L. G., Denton, E. R. E., Jarosz, J. M., Cox, T. C. S., & Hawkes, D. J. (1999) · Lecture Notes in Computer Science · doi:10.1007/3-540-48714-x_48 · Cited by 246
Modeling Brain Deformations in Alzheimer Disease by Fluid Registration of Serial 3D MR Images
Freeborough, P. A., & Fox, N. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199809000-00031 · Cited by 236
Current trends in medical image registration and fusion
El-Gamal, F. E.-Z. A., Elmogy, M., & Atwan, A. (2016) · Egyptian Informatics Journal · doi:10.1016/j.eij.2015.09.002 · Cited by 224
Longitudinal stability of MRI for mapping brain change using tensor-based morphometry
Leow, A. D., Klunder, A. D., Jack, C. R., Toga, A. W., Dale, A. M., Bernstein, M. A., Britson, P. J., Gunter, J. L., Ward, C. P., Whitwell, J. L., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.12.013 · Cited by 214
Bosc, M., Heitz, F., Armspach, J.-P., Namer, I., Gounot, D., & Rumbach, L. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00406-3 · Cited by 210
“Rigid (rotational and translational) registration has been used in Hajnal et al. (1995), Curati et al. (1996), and Rey et al. (2002), but it does not compensate for the significant voxel size changes that occur in commercial scanners.”
BackgroundRey, D., Subsol, G., Delingette, H., & Ayache, N. (2002) · Medical Image Analysis · doi:10.1016/s1361-8415(02)00056-7 · Cited by 201
Rutherford, M., Pennock, J., Schwieso, J., Cowan, F., & Dubowitz, L. (1996) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/fn.75.3.f145 · Cited by 192
Fast, accurate, and reproducible automatic segmentation of the brain in T1-weighted volume MRI data
Lemieux, L., Hagemann, G., Krakow, K., & Woermann, F. G. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199907)42:1<127::aid-mrm17>3.0.co;2-o · Cited by 186
Studholme, C., Drapaca, C., Iordanova, B., & Cardenas, V. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.872745 · Cited by 164
“SERIAL structural magnetic resonance imaging (MRI) of the brain [1], [2] is an increasingly useful tool in the study of neurodegenerative conditions [3]–[10].”
MethodGauthier, C. J., & Hoge, R. D. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.056 · Cited by 160
“Strongly hyperoxic manipulations could also create confounding effects by altering the MRI signal in the cerebrospinal fluid (CSF) due to T1 shortening (Hajnal et al., 1995).”
BackgroundFreeborough, P. A., Woods, R. P., & Fox, N. C. (1996) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199611000-00030 · Cited by 158
Metadata
- Authors
- Hajnal, J. V., Saeed, N., Oatridge, A., Williams, E. J., Young, I. R., & Bydder, G. M.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1995-09
- Volume
- 19
- Issue
- 5
- Pages
- 677-691
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W1974104848
- Cited by
- 154
- References
- 0
- FWCI
- 15.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.