The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
With the increasing manufacture of expensive systems for the measurement of ambulatory blood pressure there is a need for potential purchasers to be able to satisfy themselves that the systems have been evaluated according to agreed criteria. The British Hypertension Society has, therefore, drawn up a protocol of requirements for the evaluation of these devices. This protocol incorporates many features of the American National Standard for Non-Automated Sphygmomanometers but includes many additional features, such as strict criteria for observer training, interdevice variability testing before and after a month of ambulatory use, and a new system of analysis which permits the test system to be graded. It is recommended that manufacturers of ambulatory blood pressure measuring devices should obtain an unbiased evaluation according to a recognized standard before a device is marketed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Self-citationPickering, T. G. (1982) · JAMA · doi:10.1001/jama.247.7.992 · Cited by 526
Recommendations on blood pressure measurement.
Petrie, J. C., O'Brien, E. T., Littler, W. A., & de Swiet, M. (1986) · BMJ · doi:10.1136/bmj.293.6547.611 · Cited by 396
Self-citationA RANDOM-ZERO SPHYGMOMANOMETER
Weight, B. M., & Dore, C. F. (1970) · The Lancet · doi:10.1016/s0140-6736(70)90709-9 · Cited by 319
Prognostic value of ambulatory blood pressure measurements: further analyses.
Perloff, D. L., Sokolow, M., Cowan, R., & Juster, R. P. (1989) · PubMed · Cited by 209
Circadian blood pressure patterns in ambulatory hypertensive patients
Drayer, J. I. M., Weber, M. A., Deyoung, J. L., & Wyle, F. A. (1982) · The American Journal of Medicine · doi:10.1016/0002-9343(82)90327-8 · Cited by 137
Evaluation of performance of selected devices for measuring blood pressure
Labarthe, D. R., HAWKINS, C. M., & Remington, R. D. (1973) · The American Journal of Cardiology · doi:10.1016/s0002-9149(73)80046-3 · Cited by 118
Inaccuracy of seven popular sphygmomanometers for home measurement of blood pressure
O??Brien, E., Mee, F., Atkins, N., & O??Malley, K. (1990) · Journal of Hypertension · doi:10.1097/00004872-199007000-00005 · Cited by 71
Self-citationde Swiet, M., Dillon, M. J., Littler, W. A., O'Brien, E. T., Padfield, P. L., & Petrie, J. C. (1989) · BMJ · doi:10.1136/bmj.299.6697.497 · Cited by 64
Self-citation
Cited by
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Self-citationStaessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Human blood pressure determination by sphygmomanometry.
Perloff, D., Grim, C., Flack, J., Frohlich, E. D., Hill, M., McDonald, M., & Morgenstern, B. Z. (1993) · Circulation · doi:10.1161/01.cir.88.5.2460 · Cited by 1,591
Blood pressure measuring devices: recommendations of the European Society of Hypertension
O'Brien, E., Waeber, B., Parati, G., Staessen, J., & Myers, M. G. (2001) · BMJ · doi:10.1136/bmj.322.7285.531 · Cited by 903
Self-citationParati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Self-citationOʼBrien, E., Pickering, T., Asmar, R., Myers, M., Parati, G., Staessen, J., Mengden, T., Imai, Y., Waeber, B., Palatini, P., et al. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200202000-00002 · Cited by 744
Self-citationCuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring
Kachuee, M., Kiani, M. M., Mohammadzade, H., & Shabany, M. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2580904 · Cited by 621
O'Brien, E., Atkins, N., Stergiou, G., Karpettas, N., Parati, G., Asmar, R., Imai, Y., Wang, J., Mengden, T., & Shennan, A. (2010) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283360e98 · Cited by 610
Self-citationPrinciples and Techniques of Blood Pressure Measurement
Ogedegbe, G., & Pickering, T. (2010) · Cardiology Clinics · doi:10.1016/j.ccl.2010.07.006 · Cited by 554
Effects of Insufficient Sleep on Blood Pressure Monitored by a New Multibiomedical Recorder
Tochikubo, O., Ikeda, A., Miyajima, E., & Ishii, M. (1996) · Hypertension · doi:10.1161/01.hyp.27.6.1318 · Cited by 473
Stergiou, G. S., Alpert, B., Mieke, S., Asmar, R., Atkins, N., Eckert, S., Frick, G., Friedman, B., Graßl, T., Ichikawa, T., et al. (2018) · Hypertension · doi:10.1161/hypertensionaha.117.10237 · Cited by 469
Self-citationWhite, W. B., Berson, A. S., Robbins, C., Jamieson, M. J., Prisant, L. M., Roccella, E., & Sheps, S. G. (1993) · Hypertension · doi:10.1161/01.hyp.21.4.504 · Cited by 385
Self-citationSPECIAL ARTICLE COMPARING METHODS OF MEASUREMENT
Ludbrook, J. (1997) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.1997.tb01807.x · Cited by 363
V Diretrizes Brasileiras de Hipertensão Arterial
(2007) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x2007001500012 · Cited by 351
Avolio, A. P., Butlin, M., & Walsh, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/r01 · Cited by 310
Jananese Society of Hypertension (JSH) Guidelines for Self-Monitoring of Blood Pressure at Home
IMAI, Y., OTSUKA, K., KAWANO, Y., SHIMADA, K., HAYASHI, H., TOCHIKUBO, O., MIYAKAWA, M., & FUKIYAMA, K. (2003) · Hypertension Research · doi:10.1291/hypres.26.771 · Cited by 309
Hedner, J., Darpo, B., Ejnell, H., Carlson, J., & Caidahl, K. (1995) · European Respiratory Journal · doi:10.1183/09031936.95.08020222 · Cited by 302
Validation of the Omron HEM-907 device for blood pressure measurement
El Assaad, M. A., Topouchian, J. A., Darné, B. M., & Asmar, R. G. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200208000-00006 · Cited by 279
Stergiou, G. S., Alpert, B., Mieke, S., Asmar, R., Atkins, N., Eckert, S., Frick, G., Friedman, B., Graßl, T., Ichikawa, T., et al. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001634 · Cited by 278
“In 1990, the British Hypertension Society (BHS) published a protocol dedicated to the validation of BP monitors in the clinical setting, which incorporated many of the features of the AAMI validation standard, but also had many important differences.(3) The AAMI standard was revised in 1992 and 2002 and the BHS protoc…”
Self-citationComparing Methods of Clinical Measurement: Reporting Standards for Bland and Altman Analysis
Mantha, S., Roizen, M. F., Fleisher, L. A., Thisted, R., & Foss, J. (2000) · Anesthesia & Analgesia · doi:10.1097/00000539-200003000-00018 · Cited by 266
Validation of the mobil-O-Graph: 24 h-blood pressure measurement device
Wei, W., Tölle, M., Zidek, W., & van der Giet, M. (2010) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e328338892f · Cited by 260
Feasibility of ambulatory, continuous 24-hour finger arterial pressure recording.
Imholz, B. P., Langewouters, G. J., van Montfrans, G. A., Parati, G., van Goudoever, J., Wesseling, K. H., Wieling, W., & Mancia, G. (1993) · Hypertension · doi:10.1161/01.hyp.21.1.65 · Cited by 259
Monitoring blood glucose control in diabetes mellitus: a systematic review.
Coster, Gulliford, Seed, Powrie, & Swaminathan (2000) · Health Technology Assessment · doi:10.3310/hta4120 · Cited by 245
Prognostic relevance of pathological sympathetic activation after acute thromboembolic stroke
Sander, D., Winbeck, K., Klingelhöfer, J., Etgen, T., & Conrad, B. (2001) · Neurology · doi:10.1212/wnl.57.5.833 · Cited by 235
El Assaad, M. A., Topouchian, J. A., & Asmar, R. G. (2003) · Blood Pressure Monitoring · doi:10.1097/00126097-200306000-00006 · Cited by 224
Comparison of Auscultatory and Oscillometric Blood Pressures
Park, M. K., Menard, S. W., & Yuan, C. (2001) · Archives of Pediatrics & Adolescent Medicine · doi:10.1001/archpedi.155.1.50 · Cited by 216
“A grade of A indicates the differences to be relatively small in most comparisons, whereas B and C grades indicate a progressively lower degree of agreement.(12) A grade of D indicates an even lower degree of agreement, (less than 45% of the measurement difference is less than 5 mm Hg(12)).”
BackgroundHome Blood Pressure Measurement
Verberk, W. J., Kroon, A. A., Kessels, A. G. H., & de Leeuw, P. W. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.058 · Cited by 212
as members of the Japanese Society of Hypertension Committee for Guidelines for Self-monitoring of Blood Pressure at Home, Imai, Y., Kario, K., Shimada, K., Kawano, Y., Hasebe, N., Matsuura, H., Tsuchihashi, T., Ohkubo, T., Kuwajima, I., et al. (2012) · Hypertension Research · doi:10.1038/hr.2012.56 · Cited by 203
Flynn, J. T., Urbina, E. M., Brady, T. M., Baker-Smith, C., Daniels, S. R., Hayman, L. L., Mitsnefes, M., Tran, A., Zachariah, J. P., & on behalf of the Atherosclerosis, H. (2022) · Hypertension · doi:10.1161/hyp.0000000000000215 · Cited by 202
Blood pressure centiles for Great Britain
Jackson, L. V., Thalange, N. K. S., & Cole, T. J. (2007) · Archives of Disease in Childhood · doi:10.1136/adc.2005.081216 · Cited by 199
Oscillometric Blood Pressure Estimation: Past, Present, and Future
Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolic, M., Rajan, S., & Batkin, I. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2434215 · Cited by 196
Tanveer, M. S., & Hasan, M. K. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.02.028 · Cited by 188
“BHS grades BP measurement devices based on their cumulative frequency percentage of errors less than three different thresholds, i.e., 5, 10, and 15 mmHg [45].”
BackgroundClinical Utility of Aortic Pulses and Pressures Calculated From Applanated Radial-Artery Pulses
Smulyan, H., Siddiqui, D. S., Carlson, R. J., London, G. M., & Safar, M. E. (2003) · Hypertension · doi:10.1161/01.hyp.0000084051.34269.a9 · Cited by 179
van Popele, N. M., Bos, W. J. W., de Beer, N. A. M., van der Kuip, D. A. M., Hofman, A., Grobbee, D. E., & Witteman, J. C. M. (2000) · Hypertension · doi:10.1161/01.hyp.36.4.484 · Cited by 170
Palatini, P., Casiglia, E., Pauletto, P., Staessen, J., Kaciroti, N., & Julius, S. (1997) · Hypertension · doi:10.1161/01.hyp.30.5.1267 · Cited by 165
Asmar, R. (2011) · Vascular Health and Risk Management · doi:10.2147/vhrm.s27193 · Cited by 163
Zheng, L., Sun, Z., Li, J., Zhang, R., Zhang, X., Liu, S., Li, J., Xu, C., Hu, D., & Sun, Y. (2008) · Stroke · doi:10.1161/strokeaha.107.510677 · Cited by 161
Topouchian, J. A., El Assaad, M. A., Orobinskaia, L. V., El Feghali, R. N., & Asmar, R. G. (2006) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000209078.17246.34 · Cited by 158
State of the Market: A Review of Ambulatory Blood Pressure Monitoring Devices
O’Brien, E., Atkins, N., & Staessen, J. (1995) · Hypertension · doi:10.1161/01.hyp.26.5.835 · Cited by 158
Self-citationSharman, J. E., O’Brien, E., Alpert, B., Schutte, A. E., Delles, C., Hecht Olsen, M., Asmar, R., Atkins, N., Barbosa, E., Calhoun, D., et al. (2020) · Journal of Hypertension · doi:10.1097/hjh.0000000000002246 · Cited by 139
“In 1987, the US Association for the advancement of medical instrumentation (AAMI) developed a clinical validation protocol for BP devices [28,29], which was followed by a similar protocol from the British Hypertension Society [30,31].”
MethodSelf-citationOrthostatic hypotension: framework of the syndrome
Naschitz, J. E., & Rosner, I. (2007) · Postgraduate Medical Journal · doi:10.1136/pgmj.2007.058198 · Cited by 137
Howorka, K. (1997) · Cardiovascular Research · doi:10.1016/s0008-6363(97)00040-0 · Cited by 133
Automated blood pressure measurement in atrial fibrillation: a systematic review and meta-analysis
Stergiou, G. S., Kollias, A., Destounis, A., & Tzamouranis, D. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e32835850d7 · Cited by 120
Reactivity of Ambulatory Blood Pressure to Physical Activity Varies With Time of Day
Jones, H., Atkinson, G., Leary, A., George, K., Murphy, M., & Waterhouse, J. (2006) · Hypertension · doi:10.1161/01.hyp.0000206421.09642.b5 · Cited by 96
Validation protocols for blood pressure measuring devices in the 21st century
Stergiou, G. S., Alpert, B. S., Mieke, S., Wang, J., & O'Brien, E. (2018) · The Journal of Clinical Hypertension · doi:10.1111/jch.13294 · Cited by 92
Cameron, J. D., Stevenson, I., Reed, E., McGrath, B. P., Dart, A. M., & Kingwell, B. A. (2004) · Blood Pressure Monitoring · doi:10.1097/00126097-200410000-00007 · Cited by 75
Stergiou, G. S., Lourida, P., Tzamouranis, D., & Baibas, N. M. (2009) · Journal of Human Hypertension · doi:10.1038/jhh.2009.20 · Cited by 74
Stergiou, G. S., O'Brien, E., Myers, M., Palatini, P., Parati, G., Kollias, A., Birmpas, D., Kyriakoulis, K., Bountzona, I., Stambolliu, E., et al. (2019) · The Journal of Clinical Hypertension · doi:10.1111/jch.13710 · Cited by 53
Self-citationvan Ittersum, F. J., Wijering, R. M. J., Lambert, J., Donker, A. J. M., & Stehouwer, C. D. A. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816080-00007 · Cited by 52
The pursuit of accurate blood pressure measurement: A 35‐year travail
O'Brien, E., & Stergiou, G. S. (2017) · The Journal of Clinical Hypertension · doi:10.1111/jch.13005 · Cited by 39
Self blood pressure monitoring: a worthy substitute for ambulatory blood pressure?
McGowan, N., & Padfield, P. L. (2010) · Journal of Human Hypertension · doi:10.1038/jhh.2010.15 · Cited by 31
Self-citationZweiker, R., Schumacher, M., Fruhwald, F. M., Watzinger, N., & Klein, W. (2000) · Journal of Hypertension · doi:10.1097/00004872-200018080-00004 · Cited by 29
Novel methods of testing and calibration of oscillometric blood pressure monitors
Celler, B. G., Argha, A., Le, P. N., & Ambikairajah, E. (2018) · PLOS ONE · doi:10.1371/journal.pone.0201123 · Cited by 28
Validation of the Stabil-O-Graph blood pressure self-measurement device
Westhoff, T. H., Schmidt, S., Zidek, W., & van der Giet, M. (2008) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1002287 · Cited by 26
G. Celler, B., Butlin, M., Argha, A., Tan, I., Yong, A., & Avolio, A. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3079578 · Cited by 24
Stergiou, G. S., Lourida, P., & Tzamouranis, D. (2011) · Journal of Human Hypertension · doi:10.1038/jhh.2010.107 · Cited by 18
Park, S.-H., & Choi, Y.-K. (2020) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000414 · Cited by 14
Automated blood pressure measuring devices: how are they clinically validated for accuracy?
Ringrose, J. S., & Padwal, R. (2022) · Journal of Human Hypertension · doi:10.1038/s41371-022-00761-2 · Cited by 9
“This was followed in 1990 by the British Hypertension Society (BHS) protocol [14], in 1999 by the German Hypertension League (DHL) standard [15] and in 2002 by the European Society of Hypertension International Protocol (ESH-IP) [16].”
Method
Metadata
- Authors
- O??Brien, E., Petrie, J., Littler, W., de Swiet, M., Padfield, P. L., O??Malley, K., Jamieson, M., Altman, D., Bland, M., & Atkins, N.
- Venue
- Journal of Hypertension
- Published
- 1990-07
- Volume
- 8
- Issue
- 7
- Pages
- 607-619
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2166451543
- Cited by
- 772
- References
- 17
- FWCI
- 17.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.