CoChat

Home blood pressure: variability, comparison with office readings and proposal for reference values

de Gaudemaris, R??gis, Chau, Nguyen Phong, Mallion, Jean-Michel · 1994 · Journal of Hypertension
Cited by 83

The DOI matches its Crossref record.

Abstract

PURPOSE: A multicentre study was performed on 390 healthy subjects (210 male, 180 female) to evaluate home blood pressure versus office blood pressure. METHODS: The patients, aged 20-59 years, not on antihypertensive treatment, were not preselected by blood pressure levels. Blood pressure was measured in the doctor's office, using a mercury manometer at the fifth, sixth and seventh minute of rest, and at home by self-measurement using a validated electronic oscillometric device at the fifth, sixth and seventh minute of rest, in the morning and evening, on three consecutive days. RESULTS: The analysis of office and home measurements at the fifth, sixth and seventh minute of rest showed a significant decrease in blood pressure, mostly between the fifth and sixth minute. There was no significant variation in home pressure over the three consecutive days of measurement. Blood pressures were significantly higher in the evening than in the morning; the mean differences were 3 mmHg for systolic and 1.5 mmHg for diastolic blood pressure. Compared with office blood pressure measurement, home measurement provided significantly lower systolic and diastolic blood pressure means. Of the subjects, 78% showed a higher systolic and 69.9% a higher diastolic blood pressure with office measurement than with home measurement. Systolic and diastolic blood pressure differences were non-significantly higher for females than for males and did not differ with age. CONCLUSIONS: The comparison of the office and home measurement distributions allowed us to propose reference values for home blood pressure measurement. These were established by choosing blood pressure at the identical percentile for home measurement as we found for office measurement using the World Health Organization criteria (140/90 and 160/95 mmHg). Using this approach, the upper limit for normotension by home measurement would be 127/83 mmHg and for hypertension 147/86 mmHg. Although this approach has no prognostic value, it could be useful for the interpretation of home blood pressure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004872-199407000-00016

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 83

Metadata

Authors
de Gaudemaris, R., Chau, N. P., & Mallion, J.-M.
Venue
Journal of Hypertension
Published
1994-07
Volume
12
Issue
7
Pages
831???838
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2078371791
Cited by
83
References
0
FWCI
1.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Home blood pressure: variability, comparison with office readings and proposal for reference values. https://app.cochat.ai/papers/10.1097/00004872-199407000-00016
The paper
de Gaudemaris, R., Chau, N. P., & Mallion, J.-M. (1994). Home blood pressure: variability, comparison with office readings and proposal for reference values. Journal of Hypertension. https://doi.org/10.1097/00004872-199407000-00016

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.