The smoothness index: A new, reproducible and clinically relevant measure of the homogeneity of the blood pressure reduction with treatment for hypertension
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To introduce a new method, the smoothness index, for assessing the homogeneity of 24 h blood pressure reduction by antihypertensive treatment and to compare it with the trough : peak ratio; and to assess the ability of both indices to predict a reduction in the left ventricular mass index induced by treatment. PATIENTS AND METHODS: In 174 patients with essential hypertension and left ventricular hypertrophy, enrolled in the Study on Ambulatory Monitoring of Pressure and Lisinopril Evaluation (SAMPLE), aged 20-65 years, we measured clinic blood pressure, 24 h ambulatory blood pressure and the left ventricular mass index (echocardiography) before and after treatment with lisinopril at 20 mg with the addition of 12.5 or 25 mg hydrochlorothiazide as needed to reach a sufficient blood pressure reduction. The following parameters were computed for systolic and diastolic ambulatory blood pressure: (1) hourly and 24 h blood pressure averages (+/- SD) at baseline and after 3 and 12 months of treatment; (2) hourly blood pressure changes from baseline after 3 and 12 months of treatment, and their average (+/- SD) over 24 h; (3) the trough : peak ratio after 3 and 12 months of treatment; and (4) the smoothness index after 3 and 12 months of treatment Similar calculations were also performed at the end of a final study month during which active treatment was withdrawn and placebo was substituted (n = 164). RESULTS: The smoothness index for systolic and diastolic ambulatory blood pressure computed after 3 months of treatment was more closely related to its corresponding values after 12 months of treatment than the trough : peak ratio values computed after the same time periods were (r = 0.68 versus 0.38 for systolic and 0.68 versus 0.42 for diastolic blood pressure, respectively). The smoothness index showed an inverse correlation with the 24 h standard deviation of systolic and diastolic blood pressure (r = -0.25 and -0.16, P < 0.01 and < 0.05, respectively, for 12 months of treatment), while the trough : peak ratio did not (r = -0.01 to -0.12, NS). A treatment-induced reduction in the left ventricular mass index was related to the smoothness index for systolic and diastolic blood pressure (r = -0.35 and -0.32, P< 0.001 with 12 months of treatment), but not to the corresponding trough : peak ratios. CONCLUSIONS: The smoothness index identifies the occurrence of a balanced 24 h blood pressure reduction with treatment and correlates with the favourable effects of treatment on left ventricular hypertrophy better than the commonly used trough : peak ratio.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Sahn, D. J., DeMaria, A., Kisslo, J., & Weyman, A. (1978) · Circulation · doi:10.1161/01.cir.58.6.1072 · Cited by 7,430
Levy, D., Garrison, R. J., Savage, D. D., Kannel, W. B., & Castelli, W. P. (1990) · New England Journal of Medicine · doi:10.1056/nejm199005313222203 · Cited by 5,699
Echocardiographic determination of left ventricular mass in man. Anatomic validation of the method.
Devereux, R. B., & Reichek, N. (1977) · Circulation · doi:10.1161/01.cir.55.4.613 · Cited by 4,485
CASALE, P. N., DEVEREUX, R. B., MILNER, M., ZULLO, G., HARSHFIELD, G. A., PICKERING, T. G., & LARAGH, J. H. (1986) · Annals of Internal Medicine · doi:10.7326/0003-4819-105-2-173 · Cited by 1,078
Parati, G., Pomidossi, G., Albini, F., Malaspina, D., & Mancia, G. (1987) · Journal of Hypertension · doi:10.1097/00004872-198702000-00013 · Cited by 952
Self-citationPrognostic value of 24-hour blood pressure variability
Frattola, A., Parati, G., Cuspidi, C., Albini, F., & Mancia, G. (1993) · Journal of Hypertension · doi:10.1097/00004872-199310000-00019 · Cited by 659
Self-citationMancia, G., Zanchetti, A., Agebiti-Rosei, E., Benemio, G., De Cesaris, R., Fogari, R., Pessino, A., Porcellati, C., Salvetti, A., & Trimarco, B. (1997) · Circulation · doi:10.1161/01.cir.95.6.1464 · Cited by 596
Clinical Relevance of Nighttime Blood Pressure and of Daytime Blood Pressure Variability
Palatini, P. (1992) · Archives of Internal Medicine · doi:10.1001/archinte.152.9.1855 · Cited by 424
Muiesan, M. L., Salvetti, M., Rizzoni, D., Castellano, M., Donato, F., & Agabiti-Rosei, E. (1995) · Journal of Hypertension · doi:10.1097/00004872-199510000-00003 · Cited by 328
Self-citationFeasibility of ambulatory, continuous 24-hour finger arterial pressure recording.
Imholz, B. P., Langewouters, G. J., van Montfrans, G. A., Parati, G., van Goudoever, J., Wesseling, K. H., Wieling, W., & Mancia, G. (1993) · Hypertension · doi:10.1161/01.hyp.21.1.65 · Cited by 259
Self-citationContinuous vs intermittent blood pressure measurements in estimating 24-hour average blood pressure.
di Rienzo, M., Grassi, G., Pedotti, A., & Mancia, G. (1983) · Hypertension · doi:10.1161/01.hyp.5.2.264 · Cited by 239
Ambulatory blood pressure monitoring use in hypertension research and clinical practice.
Mancia, G., Di Rienzo, M., & Parati, G. (1993) · Hypertension · doi:10.1161/01.hyp.21.4.510 · Cited by 222
Self-citationTrazzi, S., Mutti, E., Frattola, A., Imholz, B., Parati, G., & Mancia, G. (1991) · Journal of Hypertension · doi:10.1097/00004872-199102000-00003 · Cited by 158
Self-citationGroppelli, A., Omboni, S., Parati, G., & Mancia, G. (1992) · Hypertension · doi:10.1161/01.hyp.20.2.227 · Cited by 157
Self-citationOmboni, S., Parati, G., Zanchetti, A., & Mancia, G. (1995) · Journal of Hypertension · doi:10.1097/00004872-199510000-00005 · Cited by 96
Self-citationEstimation of Blood Pressure Variability From 24-Hour Ambulatory Finger Blood Pressure
Omboni, S., Parati, G., Castiglioni, P., Rienzo, M. D., Imholz, B. P. M., Langewouters, G. J., Wesseling, K. H., & Mancia, G. (1998) · Hypertension · doi:10.1161/01.hyp.32.1.52 · Cited by 69
Self-citationValue of ambulatory blood pressure monitoring in clinical pharmacology.
Conway, J., & Coats, A. J. S. (1989) · PubMed · Cited by 69
Blood pressure variability, cardiovascular risk and antihypertensive treatment
Parati, G., Ulian, L., Santucciu, C., Omboni, S., & Mancia, G. (1995) · Journal of Hypertension · doi:10.1097/00004872-199512002-00005 · Cited by 50
Self-citationLipicky, R. J. (1994) · PubMed · Cited by 46
Omboni, S., Fogari, R., Palatini, P., RAPPELLI, A., & Mancia, G. (1998) · Hypertension · doi:10.1161/01.hyp.32.3.424 · Cited by 43
Self-citationTrough-To-Peak Versus Surface Ratio in the Assessment of Antihypertensive Agents
Bieniaszewski, L., Staessen, J. A., Byttebier, G., de Leeuw, P. W., Hedent, T. V., & Fagard, R. (1995) · Blood Pressure · doi:10.3109/08037059509077620 · Cited by 13
Cited by
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,655
Mancia, G., De Backer, G., Dominiczak, A., Cifkova, R., Fagard, R., Germano, G., Grassi, G., Heagerty, A. M., Kjeldsen, S. E., Laurent, S., et al. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e3281fc975a · Cited by 5,824
Mancia, G., Fagard, R., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Journal of Hypertension · doi:10.1097/01.hjh.0000431740.32696.cc · Cited by 5,655
Mancia, G., Kreutz, R., Brunström, M., Burnier, M., Grassi, G., Januszewicz, A., Muiesan, M. L., Tsioufis, K., Agabiti-Rosei, E., Algharably, E. A. E., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003480 · Cited by 3,473
Self-citationAuthors/Task Force Members:, Mancia, G., De Backer, G., Dominiczak, A., Cifkova, R., Fagard, R., Germano, G., Grassi, G., Heagerty, A. M., Kjeldsen, S. E., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehm236 · Cited by 2,384
Self-citation
Metadata
- Authors
- Parati, G., Omboni, S., Rizzoni, D., Agabiti-Rosei, E., & Manciaa, G.
- Venue
- Journal of Hypertension
- Published
- 1998-11
- Volume
- 16
- Issue
- 11
- Pages
- 1685-1691
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2071626971
- Cited by
- 198
- References
- 22
- FWCI
- 4.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.