Clinical value of ambulatory blood pressure monitoring
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Ambulatory blood pressure monitoring (ABPM) has now become an established clinical tool. It is appropriate to take stock and assess the situation of this technique. UPDATE ON EQUIPMENT: Important improvements in equipment have occurred, with reductions in weight, in awkwardness and in noisiness of the machines, better acceptability and tolerance by the patients, and better reliability. Validation programmes have been proposed and should be referred to. Limitations of the technique persist with intermittent recording in current practice. The reproducibility is limited in the short-term while recording over 24 h is acceptable. DIAGNOSIS AND PROGNOSIS: White-coat effect (WCE) is manifested as a transient elevation in blood pressure during the medical visit The frequency of this phenomenon, the size of the effect, age, sex and level of blood pressure (BP) or the situation of occurrence (general practitioner, specialist or nurse) have been interpreted differently. It does not seem that WCE predicts cardiovascular morbidity or mortality. White-coat hypertension (WCH) is diagnosed on the evidence of abnormal clinical measures of BP and normal ABPM. The latest upper limits of normality by ABPM recommended by the JNCVI are < 135/85 mmHg while patients are awake and < 120/75 mmHg while patients are asleep. If we accept these upper limits of normality in ABPM, WCH does not appear to be a real problem as regards risk factors or end-organ effects. In terms of prognosis, data are limited. Cardiovascular morbidity seems low in WCH but identical to that of hypertensive subjects in these studies. However, further studies are needed to confirm these results. WCH does not appear to benefit from anti-hypertensive treatment. It is obvious that the lower the BP regarded as the limit of normality, the less likely the occurrence of secondary effects of metabolism, or end-organ effects or complications in those classified as hypertensive. 24 HOUR CYCLE: One of the most specific characteristics of ABPM is the possibility of being able to discover modification or alteration of the 24 h cycle of BP. Non-dippers are classically defined as those who show a reduction in BP of less than 10/5 mmHg or 10% between the day (06.00-22.00 h) and the night, or an elevation in BP. In contrast, extreme dippers are those in whom the BP reduction is greater than 20%. CARDIOVASCULAR SYSTEM: The data remain inconclusive with regard to the existence of a consistent relationship between the lack of a nocturnal dip in blood pressure and target organ damage. As regards prognosis, it seems that an inversion of the day-night cycle is of pejorative significance. CEREBROVASCULAR SYSTEM: Almost all studies have shown that non-dippers had a significantly higher frequency of stroke than dippers. In contrast, too great a fall in nocturnal BP may be responsible for more marked cerebral ischaemia. RENAL SYSTEM: Non-dippers have a significantly elevated median urinary excretion of albumin. There is a significant correlation between the systolic BP and nocturnal diastolic BP, and urinary excretion of albumin. Various studies have confirmed the increased frequency of change in the 24 h cycle in hypertensive subjects at the stage of renal failure. DIABETES: BP abnormalities should be considered as markers of an elevated risk in diabetic subjects but cannot be considered at present as predictive of the appearance of micro-albuminuria or other abnormalities. ABPM is thus of interest in type I or type II diabetes both in the initial assessment and in the follow-up and adaptation of treatment. PHARMACO-THERAPEUTIC USES: The introduction of ABPM has truly changed the means and possibilities of approach to the study of the effects of anti-hypertensive medications, with new possibilities of analysis such as trough-peak ratio smoothness index, etc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Staessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Parati, G., Pomidossi, G., Albini, F., Malaspina, D., & Mancia, G. (1987) · Journal of Hypertension · doi:10.1097/00004872-198702000-00013 · Cited by 952
Parati, G., Saul, J. P., Di Rienzo, M., & Mancia, G. (1995) · Hypertension · doi:10.1161/01.hyp.25.6.1276 · Cited by 849
Prognostic value of 24-hour blood pressure variability
Frattola, A., Parati, G., Cuspidi, C., Albini, F., & Mancia, G. (1993) · Journal of Hypertension · doi:10.1097/00004872-199310000-00019 · Cited by 659
Mancia, G., Zanchetti, A., Agebiti-Rosei, E., Benemio, G., De Cesaris, R., Fogari, R., Pessino, A., Porcellati, C., Salvetti, A., & Trimarco, B. (1997) · Circulation · doi:10.1161/01.cir.95.6.1464 · Cited by 596
Ayman, D., & Goldshine, A. D. (1940) · The American Journal of the Medical Sciences · doi:10.1097/00000441-194010000-00005 · Cited by 293
Continuous vs intermittent blood pressure measurements in estimating 24-hour average blood pressure.
di Rienzo, M., Grassi, G., Pedotti, A., & Mancia, G. (1983) · Hypertension · doi:10.1161/01.hyp.5.2.264 · Cited by 239
White coat hypertension.: No harm for the heart.
Gosse, P., Promax, H., Durandet, P., & Clementy, J. (1993) · Hypertension · doi:10.1161/01.hyp.22.5.766 · Cited by 125
Cited by
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Self-citationPrognostic Value of Ambulatory Blood Pressure: Current Evidence and Clinical Implications
Verdecchia, P. (2000) · Hypertension · doi:10.1161/01.hyp.35.3.844 · Cited by 621
O'Brien, E. (2000) · BMJ · doi:10.1136/bmj.320.7242.1128 · Cited by 452
Inflammation, sleep, obesity and cardiovascular disease
Miller, M., & Cappuccio, F. (2007) · Current Vascular Pharmacology · doi:10.2174/157016107780368280 · Cited by 233
Behan, L.-A., Carmody, D., Rogers, B., Hannon, M. J., Davenport, C., Tormey, W., Smith, D., Thompson, C. J., Stanton, A., & Agha, A. (2016) · European Journal of Endocrinology · doi:10.1530/eje-15-1187 · Cited by 28
Metadata
- Authors
- Mallion, J.-M., Baguet, J.-P., Siché, J.-P., Tremel, F., & Gaudemaris, R. D.
- Venue
- Journal of Hypertension
- Published
- 1999-05
- Volume
- 17
- Issue
- 5
- Pages
- 585-595
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2324383715
- Cited by
- 108
- References
- 8
- FWCI
- 6.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical value of ambulatory blood pressure monitoring. https://app.cochat.ai/papers/10.1097/00004872-199917050-00001
- The paper
- Mallion, J.-M., Baguet, J.-P., Siché, J.-P., Tremel, F., & Gaudemaris, R. D. (1999). Clinical value of ambulatory blood pressure monitoring. Journal of Hypertension. https://doi.org/10.1097/00004872-199917050-00001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.