Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Slow breathing reduces chemoreflex response to hypoxia and hypercapnia, and increases baroreflex sensitivity

Abstract

OBJECTIVE: To investigate whether breathing more slowly modifies the sensitivity of the chemoreflex and baroreflex. DESIGN SETTING: University of Pavia, IRCCS Policlinico S. Matteo. PARTICIPANTS: Fifteen healthy individuals. INTERVENTIONS: Progressive isocapnic hypoxia and progressive hyperoxic hypercapnia were measured during spontaneous breathing and during a breathing rate fixed at 6 and 15 breaths per minute (b.p.m.). MAIN OUTCOME MEASURES: Variations in chemo- and baroreflex sensitivity (by monitoring ventilation, oxygen saturation, end-tidal carbon dioxide, R-R interval and blood pressure) induced by different breathing rates. RESULTS: Breathing at 6 b.p.m. depressed (P < 0.01) both hypoxic and hypercapnic chemoreflex responses, compared with spontaneous or 15 b.p.m. controlled breathing. Hypoxic and hypercapnic responses during spontaneous breathing correlated with baseline spontaneous breathing rate (r = -0.52 and r = +0.51, respectively; P = 0.05). Baroreflex sensitivity was greater (P < 0.05) during slow breathing at baseline and remained greater at end rebreathing. CONCLUSIONS: Slow breathing reduces the chemoreflex response to both hypoxia and hypercapnia. Enhanced baroreflex sensitivity might be one factor inhibiting the chemoreflex during slow breathing. A slowing breathing rate may be of benefit in conditions such as chronic heart failure that are associated with inappropriate chemoreflex activation.

Overview

Integrity signals

Registry

Crossref · 10.1097/00004872-200112000-00016

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 33 references

Research works printed but not linked: 5

  1. Rebuck, 1974, Am Rev Resp Dis, 109, 345
  2. Milic-Emili, 1975, N Engl J Med, 10, 864
  3. Shaw, 1982, Am Rev Respir Dis, 126, 37
  4. Sato, 1997, Circulation, 96, 274
  5. De Boer, 1987, Am J Physiol, 253, 680

Cited by

See all 243

Metadata

Authors
Bernardi, L., Gabutti, A., Porta, C., & Spicuzza, L.
Affiliations
  • University of Pavia (IT)
  • University of Catania (IT)
Corresponding author
Bernardi, Luciano
Venue
Journal of Hypertension
Published
2001-12
Volume
19
Issue
12
Pages
2221-2229
ISSN
0263-6352 (ISSN-L)
OpenAlex
W1994150913
Cited by
243
References
33
Citations by year
2026: 8 · 2025: 14 · 2024: 13 · 2023: 10 · 2022: 16 · 2021: 16 · 2020: 9 · 2019: 13 · 2018: 7 · 2017: 9 · 2016: 12 · 2015: 11 · 2014: 17 · 2013: 14 · 2012: 8
FWCI
2.61
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Hypertension (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Neuroscience of respiration and sleep
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
Keywords
slow-paced breathing, respiratory rate, chemoreflex sensitivity, baroreflex sensitivity, hypoxia, hypercapnia, isocapnic hypoxia, rebreathing, chronic heart failure
MeSH terms
Adult, Hypoxia, Blood Pressure, Chemoreceptor Cells, Female, Heart Rate, Humans, Hypercapnia, Male, Reflex, Respiration, Time Factors, Baroreflex

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Slow breathing reduces chemoreflex response to hypoxia and hypercapnia, and increases baroreflex sensitivity. https://app.cochat.ai/papers/10.1097/00004872-200112000-00016
The paper
Bernardi, L., Gabutti, A., Porta, C., & Spicuzza, L. (2001). Slow breathing reduces chemoreflex response to hypoxia and hypercapnia, and increases baroreflex sensitivity. Journal of Hypertension. https://doi.org/10.1097/00004872-200112000-00016

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.