Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 178

The DOI matches its Crossref record.

Inter-arm differences in blood pressure: when are they clinically significant?

Lane, Deirdre, Beevers, Michele, Barnes, Nicola, Bourne, James, John, Andrew, Malins, Simon, Beevers, D. Gareth·2002·Journal of Hypertension

Abstract

OBJECTIVE: To determine whether there is significant disparity in blood pressure between the two arms. DESIGN: Prospective, observational study. SETTING: One general hospital in Birmingham, England. PARTICIPANTS: Four hundred participants [age 56.3 +/- 19.7 years (mean +/- SD), 50% male] were recruited from staff and patients. Simultaneous bilateral blood pressure measurements were obtained using Omron HEM-705CP automated oscillatory devices; with two measurements taken in each arm. MAIN OUTCOME MEASURES: Mean inter-arm blood pressure differences and frequency of clinically important disparities. RESULTS: Mean +/- SD inter-arm differences in systolic and diastolic blood pressure were 1.81 +/- 8.6 mmHg and -0.23 +/- 8.3 mmHg, respectively. The analogous figures for mean +/- SD absolute differences were 6.32 +/- 6.12 mmHg and 5.06 +/- 6.57 mmHg, respectively. Significant differences were present between the mean right and left arm systolic blood pressure [t(399) = 4.20, P < 0.0001], and the mean absolute difference for both systolic [t(399) = 20.65; P < 0.0001] and diastolic [t(399) = 15.39; P < 0.0001] blood pressure. The variation in mean inter-arm blood pressure was unrelated to age, sex, ethnicity, arm circumference, handedness, being hypertensive, diabetic, or previous history of cardiovascular disease. Clinically significant inter-arm differences in systolic blood pressure of > 10 and > 20 mmHg were found in 20 and 3.5%, respectively; diastolic differences of > 10 and > 20 mmHg were present in 11 and 3.5%, respectively. Age was the only significant predictor of clinically significant variations in inter-arm blood pressures and mean absolute blood pressure differences. CONCLUSIONS: Significant differences in mean inter-arm systolic blood pressure, and mean absolute inter-arm systolic and diastolic blood pressure are present. This emphasizes the importance of measuring blood pressure in both arms initially to prevent this misdiagnosis of hypertension, due to normal differences in blood pressure between the arms.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004872-200206000-00019

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 178

Metadata

Authors
Lane, D., Beevers, M., Barnes, N., Bourne, J., John, A., Malins, S., & Beevers, D. G.
Venue
Journal of Hypertension
Published
2002-06
Volume
20
Issue
6
Pages
1089-1095
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2043090180
Cited by
178
References
0
FWCI
5.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Inter-arm differences in blood pressure: when are they clinically significant? https://app.cochat.ai/papers/10.1097/00004872-200206000-00019
The paper
Lane, D., Beevers, M., Barnes, N., Bourne, J., John, A., Malins, S., & Beevers, D. G. (2002). Inter-arm differences in blood pressure: when are they clinically significant? Journal of Hypertension. https://doi.org/10.1097/00004872-200206000-00019

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.