Facts and fiction of poor compliance as a cause of inadequate blood pressure control: a systematic review
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: (i) To obtain an overview of measured compliance with antihypertensive medication; (ii) to explore sources of variation in measured compliance percentages between studies; and (iii) to investigate whether studies can establish a relationship between compliance and achieved blood pressure. STUDY SELECTION: MEDLINE, PubMed and EMBASE databases were searched for studies, published between 1985 and 2003, in which patient compliance with antihypertensive medication was measured with electronic monitors. DATA EXTRACTION: A standard form was used to extract relevant data from the included articles. Two investigators extracted all data independently. RESULTS: Thirty studies were identified. The studies included were highly varied in their methods used to quantify compliance. Taking compliance and/or correct dosing were used in 20 studies. Mean taking compliance for a once-daily regimen was 94.0 +/- 4.4% and 88.2 +/- 6.5% for a twice-daily regimen. Mean correct dosing was 85.0 +/- 8.7% for a once-daily regimen and 75.3 +/- 6.5% for a twice-daily regimen. Proportions of patients with taking compliance or correct dosing </= 80% were provided by only five studies and ranged between 9 and 37%. Studies with a monitoring period exceeding 6 months showed a distinct decrease in compliance over time. Studies on the association between achieved blood pressure and compliance gave inconsistent results. CONCLUSIONS: Although poor compliance is assumed to be an important explanation for inadequate blood pressure control, any convincing empirical evidence to support this hypothesis is currently lacking. The relationship between patient compliance and blood pressure control has not yet been properly established.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1997) · Archives of Internal Medicine · doi:10.1001/archinte.1997.00440420033005 · Cited by 3,777
A systematic review of the associations between dose regimens and medication compliance
Claxton, A. J., Cramer, J., & Pierce, C. (2001) · Clinical Therapeutics · doi:10.1016/s0149-2918(01)80109-0 · Cited by 2,388
Burt, V. L., Cutler, J. A., Higgins, M., Horan, M. J., Labarthe, D., Whelton, P., Brown, C., & Roccella, E. J. (1995) · Hypertension · doi:10.1161/01.hyp.26.1.60 · Cited by 1,252
The Effect of Prescribed Daily Dose Frequency on Patient Medication Compliance
Eisen, S. A. (1990) · Archives of Internal Medicine · doi:10.1001/archinte.150.9.1881 · Cited by 817
Choo, P. W., Rand, C. S., Inui, T. S., Lee, M.-L. T., Cain, E., Cordeiro-Breault, M., Canning, C., & Platt, R. (1999) · Medical Care · doi:10.1097/00005650-199909000-00002 · Cited by 546
Iskedjian, M., Einarson, T. R., MacKeigan, L. D., Shear, N., Addis, A., Mittmann, N., & Ilersich, A. L. (2002) · Clinical Therapeutics · doi:10.1016/s0149-2918(02)85026-3 · Cited by 302
Burnier, M., Schneider, M. P., Chioléro, A., Stubi, C. L. F., & Brunner, H. R. (2001) · Journal of Hypertension · doi:10.1097/00004872-200102000-00022 · Cited by 262
Predictors of Uncontrolled Hypertension in Ambulatory Patients
Knight, E. L., Bohn, R. L., Wang, P. S., Glynn, R. J., Mogun, H., & Avorn, J. (2001) · Hypertension · doi:10.1161/hy0901.091681 · Cited by 212
Lee, J. (1996) · American Journal of Hypertension · doi:10.1016/0895-7061(96)00056-8 · Cited by 174
Microelectronic Systems for Monitoring and Enhancing Patient Compliance With Medication Regimens
Cramer, J. A. (1995) · Drugs · doi:10.2165/00003495-199549030-00001 · Cited by 172
Würzner, G., Gerster, J.-C., Chiolero, A., Maillard, M., Fallab-Stubi, C.-L., Brunner, H. R., & Burnier, M. (2001) · Journal of Hypertension · doi:10.1097/00004872-200110000-00021 · Cited by 158
Measuring Adherence in a Hypertension Clinical Trial
Hamilton, G. A. (2003) · European Journal of Cardiovascular Nursing · doi:10.1016/s1474-5151(03)00058-6 · Cited by 144
Improved compliance measures: Applications in an ambulatory hypertensive drug trial
Rudd, P., Ahmed, S., Zachary, V., Barton, C., & Bonduelle, D. (1990) · Clinical Pharmacology and Therapeutics · doi:10.1038/clpt.1990.211 · Cited by 133
Dynamics of drug regimen compliance ? its assessment by microprocessor-based monitoring
Kruse, W., & Weber, E. (1990) · European Journal of Clinical Pharmacology · doi:10.1007/bf00278582 · Cited by 131
Leenen, F. H. H., Wilson, T. W., Bolli, P., Larochelle, P. M., Myers, M. G., Handa, S., Boileau, G., & Tanner, J. (1997) · PubMed · Cited by 121
Impact of an Electronic Medication Compliance Aid on Long‐Term Blood Pressure Control
McKenney, J. M., Munroe, W. P., & Wright, J. T. (1992) · The Journal of Clinical Pharmacology · doi:10.1002/j.1552-4604.1992.tb03837.x · Cited by 120
Nuesch, R., Schroeder, K., Dieterle, T., Martina, B., & Battegay, E. (2001) · BMJ · doi:10.1136/bmj.323.7305.142 · Cited by 120
Mar, J., & Rodríguez‐Artalejo, F. (2001) · Journal of Hypertension · doi:10.1097/00004872-200101000-00020 · Cited by 117
Monitoring one-year compliance to antihypertension medication in the Seychelles.
Bovet, P., Burnier, M., Madeleine, G., Waeber, B., & Paccaud, F. M. (2002) · Europe PMC (PubMed Central) · Cited by 100
Mengden, T., Binswanger, B., Spühler, T., Weisser, B., & Vetter, W. (1993) · Journal of Hypertension · doi:10.1097/00004872-199312000-00013 · Cited by 95
Andrejak, M., Genes, N., Vaur, L., Poncelet, P., Clerson, P., & Carre, A. (2000) · American Journal of Hypertension · doi:10.1016/s0895-7061(99)00175-2 · Cited by 95
Measurement of patient compliance and the interpretation of randomized clinical trials
Stichele, R. V. (1991) · European Journal of Clinical Pharmacology · doi:10.1007/bf00280102 · Cited by 92
Kruse, W., Rampmaier, J., Ullrich, G., & Weber, E. (1994) · PubMed · Cited by 90
Compliance with aspirin or placebo in the hypertension optimal treatment (HOT) study
Waeber, B., Leonetti, G., Kolloch, R. E., & McInnes, G. T. (1999) · Journal of Hypertension · doi:10.1097/00004872-199917070-00022 · Cited by 83
Antihypertensive Medication-Taking Investigation of a Simple Regimen
Guerrero, D., Rudd, P., Bryant-Kosling, C., & Middleton, B. (1993) · American Journal of Hypertension · doi:10.1093/ajh/6.7.586 · Cited by 70
Girvin, B., McDermott, B. J., & Johnston, G. D. (1999) · Journal of Hypertension · doi:10.1097/00004872-199917110-00017 · Cited by 61
The Belgian Collaborative Study Group, Detry, J. M., Block, P., Backer, G. D., Degaute, J. P., & Six, R. O. (1995) · European Journal of Clinical Pharmacology · doi:10.1007/bf00193697 · Cited by 54
Mallion, J. M., Dutrey-Dupagne, C., Vaur, L., Genès, N., Renault, M., Elkik, F., Baguet, P., & Boutelant, S. (1996) · PubMed · Cited by 53
Why Objective Monitoring of Compliance is Important in the Management of Hypertension.
Bertholet, N., Favrat, B., Stubi, C.-L. F., Brunner, H. R., & Burnier, M. (2000) · PubMed · Cited by 51
IMPROVED BLOOD PRESSURE CONTROL BY MONITORING COMPLIANCE WITH ANTIHYPERTENSIVE THERAPY
Waeber, B., Vetter, W., Dariolp, R., Keller, U., & Brunner, H. (1999) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.1999.tb11657.x · Cited by 50
What to do when blood pressure is difficult to control
O’Rorke, J. E., & Richardson, W. S. (2001) · BMJ · doi:10.1136/bmj.322.7296.1229 · Cited by 46
Use of a Microprocessor-Equipped Tablet Box in Monitoring Compliance with Antihypertensive Treatment
Mallion, J. M., Meilhac, B., Tremel, F., Calvez, R., & Bertholom, N. (1992) · Journal of Cardiovascular Pharmacology · doi:10.1097/00005344-199219002-00011 · Cited by 32
Use of drugs with more than a twenty-four-hour duration of action
Waeber, B., Erné, P., Saxenhofer, H., & Heynen, G. (1994) · Journal of Hypertension · doi:10.1097/00004872-199412001-00014 · Cited by 29
Transdermal Clonidine as an Adjunct to Enalapril: An Evaluation of Efficacy and Patient Compliance
Weidler, D. J., Wallin, J. D., Cook, E., Dillard, D., Lewin, A. J., & Matzek, K. M. (1992) · The Journal of Clinical Pharmacology · doi:10.1002/j.1552-4604.1992.tb03860.x · Cited by 22
Lueg, M. C., Herron, J. R., & Zellner, S. R. (1991) · PubMed · Cited by 14
Patient compliance with beta‐blocker medication in general practice
Petri, H., & Urquhart, J. (1994) · Pharmacoepidemiology and Drug Safety · doi:10.1002/pds.2630030503 · Cited by 8
Cited by
Determinants of patient adherence: a review of systematic reviews
Kardas, P., Lewek, P., & Matyjaszczyk, M. (2013) · Frontiers in Pharmacology · doi:10.3389/fphar.2013.00091 · Cited by 809
Cramer, J. A., Benedict, Á., Muszbek, N., Keskinaslan, A., & Khan, Z. M. (2007) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2007.01630.x · Cited by 487
(2009) · PubMed · Cited by 359
Medication Adherence and Persistence as the Cornerstone of Effective Antihypertensive Therapy
BURNIER, M. (2006) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2006.04.006 · Cited by 358
Lee, G. K. Y., Wang, H. H. X., Liu, K. Q. L., Cheung, Y., Morisky, D. E., & Wong, M. C. S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0062775 · Cited by 234
Metadata
- Authors
- Wetzels, G. E., Nelemans, P., Schouten, J. S., & Prins, M. H.
- Venue
- Journal of Hypertension
- Published
- 2004-10
- Volume
- 22
- Issue
- 10
- Pages
- 1849-1855
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2085066808
- Cited by
- 172
- References
- 36
- FWCI
- 14.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.