Histopathologic and Physiologic Effects of Chronic Implantation of Microelectrodes in Sacral Spinal Cord of the Cat
Open accessThe DOI matches its Crossref record.
Abstract
Active microelectrodes were implanted for a period of 2 weeks to 3 months into the sacral spinal cord of 10 male cats in order to test the feasibility and the safety of discrete stimulation of the parasympathetic preganglionic nucleus for future clinical applications of microelectrode technology in micturition control. An array of four 50 microns-diameter iridium microelectrodes was inserted beneath the dura in each cat. At weekly intervals, bladder pressure was measured as hydrostatic pressure on an intraluminal catheter. At the end of the period, histopathology was evaluated with serial transverse epoxy sections. Observations included diffuse and focal axonal degeneration in white matter and possible neuronal loss around the electrode in the gray matter, meningeal ensheathment of the shafts, and occasional aseptic inflammation of tissue and apparent movement of the electrodes after implantation. Increased bladder pressure responses to individually pulsed electrodes located within the sacral parasympathetic nucleus were not consistent, and, surprisingly, at least 2 different sites were also effective. As long as 3 months after implantation, in 2 out of 5 animals, pulsing of electrodes consistently produced micturition. We conclude that while microelectrode implants are feasible, further modifications in electrode design are needed to eliminate movement and inflammation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S., Spence, A. J., Isaacson, M., Craighead, H. G., Turner, J. N., & Shain, W. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 796
Cerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M., & Craighead, H. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 592
Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301
“spinal cord [3]–[5], peripheral nerve fibers [6]–[17], and the motor end plates of the muscles directly [18]–[20].”
BackgroundNo tissue damage by chronic deep brain stimulation in Parkinson's disease
Haberler, C., Alesch, F., Mazal, P. R., Pilz, P., Jellinger, K., Pinter, M. M., Hainfellner, J. A., & Budka, H. (2000) · Annals of Neurology · doi:10.1002/1531-8249(200009)48:3<372::aid-ana12>3.0.co;2-0 · Cited by 258
Tapping into spinal circuits to restore motor function
Barbeau, H., McCrea, D. A., O'Donovan, M. J., Rossignol, S., Grill, W. M., & Lemay, M. A. (1999) · Brain Research Reviews · doi:10.1016/s0165-0173(99)00008-9 · Cited by 212
Biocompatibility of intracortical microelectrodes: current status and future prospects
Marin, C. (2010) · Frontier in Neuroengineering · doi:10.3389/fneng.2010.00008 · Cited by 160
“…are acute and chronic inflammatory reactions which affect both the neural tissue and the surface of the microelectrodes (Hoogerwerf and Wise, 1994; Woodford et al., 1996; Heiduschka and Thanos, 1998; Agnew et al., 1999; Liu et al., 1999; Majji et al., 1999; Turner et al., 1999; McCreery et al.,…”
Maynard, E. M. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.145 · Cited by 126
Implantable bioelectronic interfaces for lost nerve functions
Heiduschka, P., & Thanos, S. (1998) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00013-6 · Cited by 126
Development of a cortical visual neuroprosthesis for the blind: the relevance of neuroplasticity
Fernández, E., Pelayo, F., Romero, S., Bongard, M., Marin, C., Alfaro, A., & Merabet, L. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/r01 · Cited by 105
“Although it has been reported that silicon-based shafts, silicon oxide based surfaces and other glass based products are highly biocompatible [94], there are acute and chronic inflammatory reactions which affect both the neural tissue and the surface of the microelectrodes [1, 44, 45, 57, 61, 65, 104, 113].”
BackgroundJezernik, S., Craggs, M., Grill, W. M., Creasey, G., & Rijkhoff, N. J. M. (2002) · Neurological Research · doi:10.1179/016164102101200294 · Cited by 102
Biotolerability of Intracortical Microelectrodes
Fernández, E., & Botella, P. (2018) · Advanced Biosystems · doi:10.1002/adbi.201700115 · Cited by 11
Metadata
- Authors
- Woodford, B. J., Carter, R. R., McCreery, D., Bullara, L. A., & Agnew, W. F.
- Venue
- Journal of Neuropathology and Experimental Neurology
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-09
- Volume
- 55
- Issue
- 9
- Pages
- 982-991
- ISSN
- 0022-3069 (ISSN-L)
- OpenAlex
- W2045196723
- Cited by
- 47
- References
- 0
- FWCI
- 0.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.