Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 164

The DOI matches its Crossref record.

Intraoperative Electrophysiologic Monitoring of the Recurrent Laryngeal Nerve

Eisele, David W.·1996·The Laryngoscope

Abstract

Intraoperative electrophysiologic monitoring of the recurrent laryngeal nerve was performed with a commercially available device consisting of an endotracheal tube with integrated stainless‐steel‐wire surface EMG electrodes positioned at the level of the true vocal cords. Forty‐two recurrent laryngeal nerves were successfully monitored with this system in 31 patients undergoing thyroidectomy or parathyroidectomy. In all cases, evoked EMG responses were elicited by direct electrical recurrent laryngeal nerve stimulation. Stimulus thresholds for evoked responses ranged from 0.2 to 0.6 mA (mean 0.3 mA) for the 37 nerves with preoperative ipsilateral normal vocal cord mobility. Mechanically evoked potentials with acoustic signals were also detected during the surgical procedures related to recurrent laryngeal nerve manipulation. It may be concluded that surface electrode monitoring of the recurrent laryngeal nerve with this system provides a simplified, noninvasive technique that is as sensitive as monitoring with intramuscular laryngeal electrodes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00005537-199604000-00010

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 164

Metadata

Authors
Eisele, D. W.
Venue
The Laryngoscope
Publisher
Wiley
Published
1996-04
Volume
106
Issue
4
Pages
443-449
ISSN
  • 0023-852X (ISSN-L)
  • 1531-4995
OpenAlex
W2057386745
Cited by
164
References
0
FWCI
3.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intraoperative Electrophysiologic Monitoring of the Recurrent Laryngeal Nerve. https://app.cochat.ai/papers/10.1097/00005537-199604000-00010
The paper
Eisele, D. W. (1996). Intraoperative Electrophysiologic Monitoring of the Recurrent Laryngeal Nerve. The Laryngoscope. https://doi.org/10.1097/00005537-199604000-00010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.