Intraoperative Electrophysiologic Monitoring of the Recurrent Laryngeal Nerve
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Intraoperative electrophysiologic monitoring of the recurrent laryngeal nerve was performed with a commercially available device consisting of an endotracheal tube with integrated stainless‐steel‐wire surface EMG electrodes positioned at the level of the true vocal cords. Forty‐two recurrent laryngeal nerves were successfully monitored with this system in 31 patients undergoing thyroidectomy or parathyroidectomy. In all cases, evoked EMG responses were elicited by direct electrical recurrent laryngeal nerve stimulation. Stimulus thresholds for evoked responses ranged from 0.2 to 0.6 mA (mean 0.3 mA) for the 37 nerves with preoperative ipsilateral normal vocal cord mobility. Mechanically evoked potentials with acoustic signals were also detected during the surgical procedures related to recurrent laryngeal nerve manipulation. It may be concluded that surface electrode monitoring of the recurrent laryngeal nerve with this system provides a simplified, noninvasive technique that is as sensitive as monitoring with intramuscular laryngeal electrodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Riddell, V. (1970) · British journal of surgery · doi:10.1002/bjs.1800570102 · Cited by 168
Recurrent Laryngeal Nerve Palsy in Thyroid Gland Surgery Related to Operations and Nerves at Risk
Mårtensson, H. (1985) · Archives of Surgery · doi:10.1001/archsurg.1985.01390280065014 · Cited by 143
COMPLICATIONS OF SECONDARY THYROIDECTOMY.
Beahrs, O. H., & Vandertoll, D. J. (1963) · PubMed · Cited by 133
Recurrent Laryngeal Nerve Localization Using a Microlaryngeal Electrode
Davis, W. E., Rea, J. L., & Templer, J. W. (1979) · Otolaryngology · doi:10.1177/019459987908700309 · Cited by 71
Cited by
Randolph, G. W., Dralle, H., with the International Intraoperative Monitoring Study Group, Abdullah, H., Barczynski, M., Bellantone, R., Brauckhoff, M., Carnaille, B., Cherenko, S., Chiang, F., et al. (2011) · The Laryngoscope · doi:10.1002/lary.21119 · Cited by 1,047
Intraoperative Monitoring of the Recurrent Laryngeal Nerve in Thyroid Surgery
Dralle, H., Sekulla, C., Lorenz, K., Brauckhoff, M., Machens, A., & the German IONM Study Group (2008) · World Journal of Surgery · doi:10.1007/s00268-008-9483-2 · Cited by 504
Clinical Practice Guideline: Improving Voice Outcomes after Thyroid Surgery
Chandrasekhar, S. S., Randolph, G. W., Seidman, M. D., Rosenfeld, R. M., Angelos, P., Barkmeier‐Kraemer, J., Benninger, M. S., Blumin, J. H., Dennis, G., Hanks, J., et al. (2013) · Otolaryngology–Head and Neck Surgery · doi:10.1177/0194599813487301 · Cited by 466
Intraoperative neuromonitoring of surgery for benign goiter
Thomusch, O., Sekulla, C., Walls, G., Machens, A., & Dralle, H. (2002) · The American Journal of Surgery · doi:10.1016/s0002-9610(02)00856-5 · Cited by 192
The Control of Vocal Pitch in Human Laryngeal Motor Cortex
Dichter, B. K., Breshears, J. D., Leonard, M. K., & Chang, E. F. (2018) · Cell · doi:10.1016/j.cell.2018.05.016 · Cited by 183
“In the first stimulation experiment, participants undergoing neurosurgical procedures with general anesthesia were intubated with a specialized endotracheal tube with electromyographic (EMG) non-penetrating wire electrodes (Eisele, 1996; Rea and Khan, 1998).”
Recurrent Laryngeal Nerve Injury in Thyroid Surgery
Zakaria (2011) · Oman Medical Journal · doi:10.5001/omj.2011.09 · Cited by 167
Metadata
- Authors
- Eisele, D. W.
- Venue
- The Laryngoscope
- Publisher
- Wiley
- Published
- 1996-04
- Volume
- 106
- Issue
- 4
- Pages
- 443-449
- ISSN
- 0023-852X (ISSN-L)
- 1531-4995
- OpenAlex
- W2057386745
- Cited by
- 164
- References
- 4
- FWCI
- 3.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.