Comparative Study of Cochlear Damage With Three Perimodiolar Electrode Designs
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Objective To describe intracochlear insertion trauma caused by three perimodiolar cochlear implant electrodes. Study Design Descriptive histological study of 15 human cadaver temporal bones. Methods Fifteen cadaver temporal bones underwent surface preparation and were implanted with one of the following perimodiolar electrode arrays: Combi 40+PM (MedEl Corporation), HiFocus II (Advanced Bionics Corporation), or Contour (Cochlear Corporation). A cryosectioning technique was used to study horizontal sections at 200‐μm intervals with the electrode in place. Image‐enhanced videofluoroscopy and computer‐assisted morphometrics were used to assess the mechanism of insertion trauma and to determine electrode position within the modiolus. Results Histological examination revealed varying degrees of damage to the spiral ligament, basilar membrane, and osseous spiral lamina. Using a novel grading system for electrode trauma, there was no statistically significant difference among the three electrodes. A literature search of histological studies of a commonly used “standard” electrode showed damage equal to or greater than that seen in the current study. Conclusions Insertion trauma caused by periomodiolar electrodes occurs to an acceptable degree. Refinement of electrodes based on mechanisms of trauma may be able to further reduce damage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitation
Shepherd, R. K., Hatsushika, S., & Clark, G. M. (1993) · Hearing Research · doi:10.1016/0378-5955(93)90265-3 · Cited by 360
Histopathology of Cochlear Implants in Humans
Nadol, J. B., Burgess, B. J., Gantz, B. J., Coker, N. J., Ketten, D. R., Kos, I., Roland, J. T., Shiao, J. Y., Eddington, D. K., Montandon, P., et al. (2001) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348940111000914 · Cited by 292
Comparison of electrode position in the human cochlea using various perimodiolar electrode arrays
Tykocinski, M., Cohen, L. T., Pyman, B. C., ROLANDJR, T., Treaba, C. G., Palamara, J. E. A., DAHM, M., Shepherd, R. K., Xu, J., & Cowan, R. S. (2000) · American Journal of Otolaryngology · doi:10.1016/s0196-0709(00)80010-1 · Cited by 112
Electrode Insertion Trauma in Cochlear Implantation
O'Leary, M. J., House, W. F., Fayad, J. N., & Linthicum, F. H. (1991) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348949110000901 · Cited by 97
Insertional trauma of multichannel cochlear implants
Welling, D. B., Hinojosa, R., Gantz, B. J., & Lee, J. (1993) · The Laryngoscope · doi:10.1288/00005537-199309000-00010 · Cited by 75
Electrode to modiolus proximity: A fluoroscopic and histologic analysis
Roland, J. T., Fishman, A. J., Alexiades, G., & Cohen, N. L. (2000) · American Journal of Otolaryngology · doi:10.1016/s0196-0709(00)80012-5 · Cited by 73
Modiolar Proximity of Three Perimodiolar Cochlear Implant Electrodes
Bałkany, T. J., Eshraghi, A. A., & Yang, N. W. (2002) · Acta Oto-Laryngologica · doi:10.1080/00016480260000021 · Cited by 54
Self-citation
Cited by
An overview of cochlear implant electrode array designs
Dhanasingh, A., & Jolly, C. (2017) · Hearing Research · doi:10.1016/j.heares.2017.10.005 · Cited by 311
The cochlear implant: historical aspects and future prospects
Eshraghi, A. A., Nazarian, R., Telischi, F. F., Rajguru, S. M., Truy, E., & Gupta, C. (2012) · The Anatomical Record · doi:10.1002/ar.22580 · Cited by 285
“Several studies have been performed, which include the use of commercial and experimental perimodiolar electrode models (Eshraghi et al., 2003, Wardrop et al., 2005, Adunka et al., 2006).”
BackgroundMethodAdunka, O., Unkelbach, M. H., MacK, M., Hambek, M., Gstoettner, W., & Kiefer, J. (2004) · Acta Oto-Laryngologica · doi:10.1080/00016480410018179 · Cited by 228
Multichannel Cochlear Implants: Relation of Histopathology to Performance
Fayad, J. N., & Linthicum, F. H. (2006) · The Laryngoscope · doi:10.1097/01.mlg.0000227176.09500.28 · Cited by 222
Rebscher, S. J. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.08.0119 · Cited by 169
Metadata
- Authors
- Eshraghi, A. A., Yang, N. W., & Balkany, T. J.
- Venue
- The Laryngoscope
- Publisher
- Wiley
- Published
- 2003-03
- Volume
- 113
- Issue
- 3
- Pages
- 415-419
- ISSN
- 0023-852X (ISSN-L)
- 1531-4995
- OpenAlex
- W1987080528
- Cited by
- 257
- References
- 7
- FWCI
- 5.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.