The DOI matches its Crossref record; 11 of the 12 references it cites were found in a registry or an index.
Accuracy of five electronic pedometers for measuring distance walked
Abstract
This is a three-part study that examined the accuracy of five brands of electronic pedometers (Freestyle Pacer, Eddie Bauer, L.L. Bean, Yamax, and Accusplit) under a variety of different conditions. In Part I, 20 subjects walked a 4.88-km sidewalk course while wearing two devices of the same brand (on the left and right side of the body) for each of five different trials. There were significant differences among pedometers (P < 0.05), with the Yamax, Pacer, and Accusplit approximating the actual distance more closely than the other models. The Yamax pedometers showed close agreement, but the left and right Pacer pedometers differed significantly (P = 0.0003) and the Accusplit displayed a similar trend (P = 0.0657). In Part II, the effects of walking surface on pedometer accuracy were examined. Ten of the original subjects completed an additional five trials around a 400-m rubberized outdoor track. The devices showed similar values for sidewalk and track surfaces. In Part III, the effects of walking speed on pedometer accuracy were examined. Ten different subjects walked on a treadmill at various speeds (54, 67, 80, 94, and 107 m.min-1). Pedometers that displayed both distance and number of steps were examined. The Yamax was more accurate than the Pacer and Eddie Bauer at slow-to-moderate speeds (P < 0.05), though no significant differences were seen at the fastest speed. While there are variations among brands in terms of accuracy, electronic pedometers may prove useful in recording walking activities in free-living populations.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“One pedometer (Yamax DW-500) was found to be more accurate and reliable than others [12].”
From Step Counting: A Review of Measurement Considerations and Health-Related Applications (2017) · cites this paper as [12]
In the citing paper
“Good step counters can record steps within this range during walking at 80.4 m/min, or 3 mph [12, 18, 24, 38, 39].”
From Step Counting: A Review of Measurement Considerations and Health-Related Applications (2017) · cites this paper as [12]
Citations
Cites
Comprehensive evaluation of the Minnesota leisure time physical activity questionnaire
Richardson, M. T., Leon, A. S., Jacobs, D. R., Ainsworth, B. E., & SERFASS, R. C. (1994) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(94)90008-6 · Cited by 369
Self-citationYamanouchi, K., Shinozaki, T., Chikada, K., Nishikawa, T., Ito, K., Shimizu, S., Ozawa, N., Suzuki, Y., Maeno, H., Kato, K., et al. (1995) · Diabetes Care · doi:10.2337/diacare.18.6.775 · Cited by 330
Accuracy of the College Alumnus Physical Activity Questionnaire
Ainsworth, B. E., Leon, A. S., Richardson, M. T., Jacobs, D. R., & Paffenbarger, R. S. (1993) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(93)90140-v · Cited by 295
Self-citationMethods to assess physical activity with special reference to motion sensors and accelerometers
Meijer, G. A. L., Westerterp, K. R., Verhoeven, F. M. H., Koper, H. B. M., & ten Hoor, F. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.133202 · Cited by 162
Validation of a simple mechanical accelerometer (pedometer) for the estimation of walking activity
Bassey, E. J., Dallosso, H. M., Fentem, P. H., Irving, J. M., & Patrick, J. M. (1987) · European Journal of Applied Physiology · doi:10.1007/bf00690900 · Cited by 91
Saris, W. H. M., & BINKHORST, R. A. (1977) · European Journal of Applied Physiology · doi:10.1007/bf00421777 · Cited by 76
Kashiwazaki, H., Inaoka, T., Suzuki, T., & Kondo, Y. (1986) · European Journal of Applied Physiology · doi:10.1007/bf00943345 · Cited by 46
Validity and reliability of pedometers in habitual activity research
Kemper, H. C. G., & Verschuur, R. (1977) · European Journal of Applied Physiology · doi:10.1007/bf00421600 · Cited by 40
Estimation of energy expenditure during walking and jogging by using an electro-pedometer.
Mizuno, C. A., Yoshida, T., & Masao, U. D. O. (1990) · The Annals of physiological anthropology · doi:10.2114/ahs1983.9.283 · Cited by 14
Utilisation des compteurs de mouvements pour la mesure de l'activité physique
Montoye, H. J. (1988) · Science & Sports · doi:10.1016/s0765-1597(88)80043-1 · Cited by 9
Research works printed but not linked: 2
- Gayle, 1977, Res Q, 48, 632
- Washburn, 1980, Res Q, 51, 695
Cited by
Sorted by citations
Using Pedometers to Increase Physical Activity and Improve Health: A Systematic Review
Bravata, D. M., Smith-Spangler, C., Sundaram, V., Gienger, A. L., Lin, N., Lewis, R., Stave, C. D., Olkin, I., & Sirard, J. R. (2007) · JAMA · doi:10.1001/jama.298.19.2296 · Cited by 2,064
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Self-citationPhysical Activity Assessment in Children and Adolescents
Sirard, J. R., & Pate, R. R. (2001) · Sports Medicine · doi:10.2165/00007256-200131060-00004 · Cited by 1,044
Validity of accelerometry for the assessment of moderate intensity physical activity in the field
HENDELMAN, D., MILLER, K., BAGGETT, C., DEBOLD, E., & FREEDSON, P. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00002 · Cited by 516
Pedometer Measures of Free-Living Physical Activity: Comparison of 13 Models
SCHNEIDER, P. L., Crouter, S. E., & Bassett, D. R. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000113486.60548.e9 · Cited by 752
Self-citation
Metadata
- Authors
- BASSETT, D. R., AINSWORTH, B. E., LEGGETT, S. R., MATHIEN, C. A., MAIN, J. A., HUNTER, D. C., & DUNCAN, G. E.
- Affiliations
- University of South Carolina (US)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1996-08
- Volume
- 28
- Issue
- 8
- Pages
- 1071-1077
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2003135851
- Cited by
- 552
- References
- 12
- Citations by year
- 2025: 3 · 2024: 1 · 2023: 8 · 2022: 6 · 2021: 4 · 2020: 7 · 2019: 14 · 2018: 12 · 2017: 13 · 2016: 24 · 2015: 12 · 2014: 18 · 2013: 30 · 2012: 27
- FWCI
- 2.02
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- walking distance, walking speed, walking surfaces, step counting
- MeSH terms
- Adolescent, Adult, Aged, Electronics, Equipment and Supplies, Female, Humans, Male, Middle Aged, Exercise, Walking
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review