CoChat

Comparison of accelerometers with oxygen consumption in older adults during exercise

FEHLING, PATRICIA C., SMITH, DENISE L., WARNER, SARAH E., DALSKY, GAIL P. · 1999 · Medicine & Science in Sports & Exercise
Cited by 85

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

PURPOSE: The purpose of this study was to compare two commercially available accelerometers with indirect calorimetry in a group of older adults (x +/- SD; 70.6+/-3.7 yr; N = 86, 44 males and 42 females). METHODS: The accelerometers (Caltrac and Tritrac, Hemokinetics, Madison, WI) were worn while performing three submaximal, discontinuous (5 min exercise, 2 min recovery), progressive levels of treadmill walking and bench stepping. The treadmill exercise averaged 3.4 mph, at 0.4% grade, 3.0% grade, and 5.1% grade, while the stepping work rates (24 steps x min(-1)) were performed on 15.2-, 20.3-, and 25.4-cm steps. Estimated energy expenditure (EE) from the two accelerometers was compared with EE as measured by indirect calorimetry. RESULTS: The Caltrac significantly (P < 0.05) overestimated EE at the three treadmill work rates (10-52% difference) and underestimated EE at the three stepping work rates (-19% to -28% difference). When comparing the changes in EE between work rates one, two and three, the Caltrac was not sensitive to the changes (increase in EE) that occurred during graded treadmill walking but did detect some changes in the stepping exercise. The Tritrac significantly (P < 0.05) underestimated EE for the three work rates of both the treadmill and stepping exercise when compared with indirect calorimetry but did detect differences in EE among work rates during stepping exercise (P < 0.05). CONCLUSIONS: These data indicate that the magnitude of the differences between measured and estimated EE is affected by exercise mode and intensity and that caution is warranted when using the accelerometers in an attempt to quantify EE in older adults.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00005768-199901000-00026

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 85

Metadata

Authors
FEHLING, P. C., SMITH, D. L., WARNER, S. E., & DALSKY, G. P.
Venue
Medicine & Science in Sports & Exercise
Published
1999-01
Volume
31
Issue
1
Pages
171-175
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2074924751
Cited by
85
References
2
FWCI
1.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of accelerometers with oxygen consumption in older adults during exercise. https://app.cochat.ai/papers/10.1097/00005768-199901000-00026
The paper
FEHLING, P. C., SMITH, D. L., WARNER, S. E., & DALSKY, G. P. (1999). Comparison of accelerometers with oxygen consumption in older adults during exercise. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-199901000-00026

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.