Comparison of accelerometers with oxygen consumption in older adults during exercise
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PURPOSE: The purpose of this study was to compare two commercially available accelerometers with indirect calorimetry in a group of older adults (x +/- SD; 70.6+/-3.7 yr; N = 86, 44 males and 42 females). METHODS: The accelerometers (Caltrac and Tritrac, Hemokinetics, Madison, WI) were worn while performing three submaximal, discontinuous (5 min exercise, 2 min recovery), progressive levels of treadmill walking and bench stepping. The treadmill exercise averaged 3.4 mph, at 0.4% grade, 3.0% grade, and 5.1% grade, while the stepping work rates (24 steps x min(-1)) were performed on 15.2-, 20.3-, and 25.4-cm steps. Estimated energy expenditure (EE) from the two accelerometers was compared with EE as measured by indirect calorimetry. RESULTS: The Caltrac significantly (P < 0.05) overestimated EE at the three treadmill work rates (10-52% difference) and underestimated EE at the three stepping work rates (-19% to -28% difference). When comparing the changes in EE between work rates one, two and three, the Caltrac was not sensitive to the changes (increase in EE) that occurred during graded treadmill walking but did detect some changes in the stepping exercise. The Tritrac significantly (P < 0.05) underestimated EE for the three work rates of both the treadmill and stepping exercise when compared with indirect calorimetry but did detect differences in EE among work rates during stepping exercise (P < 0.05). CONCLUSIONS: These data indicate that the magnitude of the differences between measured and estimated EE is affected by exercise mode and intensity and that caution is warranted when using the accelerometers in an attempt to quantify EE in older adults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Accuracy of five electronic pedometers for measuring distance walked
BASSETT, D. R., AINSWORTH, B. E., LEGGETT, S. R., MATHIEN, C. A., MAIN, J. A., HUNTER, D. C., & DUNCAN, G. E. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199608000-00019 · Cited by 552
Calorimetric Validation of the Caltrac® Accelerometer during Level Walking
Balogun, J. A., Martin, D. A., & Clendenin, M. A. (1989) · Physical Therapy · doi:10.1093/ptj/69.6.501 · Cited by 57
Cited by
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Mathie, M. J., Coster, A. C. F., Lovell, N. H., & Celler, B. G. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/2/r01 · Cited by 829
Direct measurement of human movement by accelerometry
Godfrey, A., Conway, R., Meagher, D., & ÓLaighin, G. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.09.005 · Cited by 591
Kumahara, H., Schutz, Y., Ayabe, M., Yoshioka, M., Yoshitake, Y., Shindo, M., Ishii, K., & Tanaka, H. (2004) · British Journal of Nutrition · doi:10.1079/bjn20031033 · Cited by 534
Validity of accelerometry for the assessment of moderate intensity physical activity in the field
HENDELMAN, D., MILLER, K., BAGGETT, C., DEBOLD, E., & FREEDSON, P. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00002 · Cited by 516
Metadata
- Authors
- FEHLING, P. C., SMITH, D. L., WARNER, S. E., & DALSKY, G. P.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1999-01
- Volume
- 31
- Issue
- 1
- Pages
- 171-175
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2074924751
- Cited by
- 85
- References
- 2
- FWCI
- 1.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of accelerometers with oxygen consumption in older adults during exercise. https://app.cochat.ai/papers/10.1097/00005768-199901000-00026
- The paper
- FEHLING, P. C., SMITH, D. L., WARNER, S. E., & DALSKY, G. P. (1999). Comparison of accelerometers with oxygen consumption in older adults during exercise. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-199901000-00026
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.