Comparison of accelerometers with oxygen consumption in older adults during exercise
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PURPOSE: The purpose of this study was to compare two commercially available accelerometers with indirect calorimetry in a group of older adults (x +/- SD; 70.6+/-3.7 yr; N = 86, 44 males and 42 females). METHODS: The accelerometers (Caltrac and Tritrac, Hemokinetics, Madison, WI) were worn while performing three submaximal, discontinuous (5 min exercise, 2 min recovery), progressive levels of treadmill walking and bench stepping. The treadmill exercise averaged 3.4 mph, at 0.4% grade, 3.0% grade, and 5.1% grade, while the stepping work rates (24 steps x min(-1)) were performed on 15.2-, 20.3-, and 25.4-cm steps. Estimated energy expenditure (EE) from the two accelerometers was compared with EE as measured by indirect calorimetry. RESULTS: The Caltrac significantly (P < 0.05) overestimated EE at the three treadmill work rates (10-52% difference) and underestimated EE at the three stepping work rates (-19% to -28% difference). When comparing the changes in EE between work rates one, two and three, the Caltrac was not sensitive to the changes (increase in EE) that occurred during graded treadmill walking but did detect some changes in the stepping exercise. The Tritrac significantly (P < 0.05) underestimated EE for the three work rates of both the treadmill and stepping exercise when compared with indirect calorimetry but did detect differences in EE among work rates during stepping exercise (P < 0.05). CONCLUSIONS: These data indicate that the magnitude of the differences between measured and estimated EE is affected by exercise mode and intensity and that caution is warranted when using the accelerometers in an attempt to quantify EE in older adults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Accuracy of five electronic pedometers for measuring distance walked
BASSETT, D. R., AINSWORTH, B. E., LEGGETT, S. R., MATHIEN, C. A., MAIN, J. A., HUNTER, D. C., & DUNCAN, G. E. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199608000-00019 · Cited by 552
Calorimetric Validation of the Caltrac® Accelerometer during Level Walking
Balogun, J. A., Martin, D. A., & Clendenin, M. A. (1989) · Physical Therapy · doi:10.1093/ptj/69.6.501 · Cited by 57
Cited by
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Mathie, M. J., Coster, A. C. F., Lovell, N. H., & Celler, B. G. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/2/r01 · Cited by 829
Direct measurement of human movement by accelerometry
Godfrey, A., Conway, R., Meagher, D., & ÓLaighin, G. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.09.005 · Cited by 591
Kumahara, H., Schutz, Y., Ayabe, M., Yoshioka, M., Yoshitake, Y., Shindo, M., Ishii, K., & Tanaka, H. (2004) · British Journal of Nutrition · doi:10.1079/bjn20031033 · Cited by 534
Validity of accelerometry for the assessment of moderate intensity physical activity in the field
HENDELMAN, D., MILLER, K., BAGGETT, C., DEBOLD, E., & FREEDSON, P. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00002 · Cited by 516
Accelerometer Assessment of Physical Activity in Active, Healthy Older Adults
Copeland, J. L., & Esliger, D. W. (2009) · Journal of Aging and Physical Activity · doi:10.1123/japa.17.1.17 · Cited by 412
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
Actigraph GT3X: Validation and Determination of Physical Activity Intensity Cut Points
Santos-Lozano, A., Santín-Medeiros, F., Cardon, G., Torres-Luque, G., Bailón, R., Bergmeir, C., Ruiz, J., Lucia, A., & Garatachea, N. (2013) · International Journal of Sports Medicine · doi:10.1055/s-0033-1337945 · Cited by 383
A comparative evaluation of three accelerometry-based physical activity monitors
WELK, G. J., BLAIR, S. N., WOOD, K., JONES, S., & THOMPSON, R. W. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00008 · Cited by 343
Principles of Design and Analyses for the Calibration of Accelerometry-Based Activity Monitors
WELK, G. J. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185660.38335.de · Cited by 339
The utility of the Digi-Walker step counter to assess daily physical activity patterns
WELK, G. J., DIFFERDING, J. A., THOMPSON, R. W., BLAIR, S. N., DZIURA, J., & HART, P. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00007 · Cited by 293
Quantitating Physical Activity in COPD Using a Triaxial Accelerometer
Steele, B. G., Holt, L., Belza, B., Ferris, S., Lakshminaryan, S., & Buchner, D. M. (2000) · Chest · doi:10.1378/chest.117.5.1359 · Cited by 287
Validity of activity monitors in health and chronic disease: a systematic review
Van Remoortel, H., Giavedoni, S., Raste, Y., Burtin, C., Louvaris, Z., Gimeno-Santos, E., Langer, D., Glendenning, A., Hopkinson, N. S., Vogiatzis, I., et al. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-84 · Cited by 277
Comparison of Activity Monitors to Estimate Energy Cost of Treadmill Exercise
KING, G. A., TORRES, N., POTTER, C., BROOKS, T. J., & COLEMAN, K. J. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000132379.09364.f8 · Cited by 238
Kowalski, K., Rhodes, R., Naylor, P.-J., Tuokko, H., & MacDonald, S. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-148 · Cited by 212
“However, this was not a uniform finding; accelerometers both overestimated (10–52%) and underestimated (−12% to −60%) energy expenditure from indirect calorimetry in one study [58] and underestimated energy expenditure (−2%) in the other [62].”
BackgroundMethodInfluentialMicroprocessor-based ambulatory activity monitoring in stroke patients
MACKO, R. F., HAEUBER, E., SHAUGHNESSY, M., COLEMAN, K. L., BOONE, D. A., SMITH, G. V., & SILVER, K. H. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200203000-00002 · Cited by 185
Exercise training in adults with congenital heart disease: Feasibility and benefits
Dua, J. S., Cooper, A. R., Fox, K. R., & Graham Stuart, A. (2010) · International Journal of Cardiology · doi:10.1016/j.ijcard.2009.01.038 · Cited by 159
“It has been validated against the ‘doubly-labelled’ water method in healthy adults [45] and correlates well with other assessments of physical activity including treadmill walking [46].”
BackgroundPhysical activity and exercise: Recent advances and current challenges.
Dubbert, P. M. (2002) · Journal of Consulting and Clinical Psychology · doi:10.1037//0022-006x.70.3.526 · Cited by 159
Activity Monitoring and Energy Expenditure in COPD Patients: A Validation Study
Patel, S. A., Benzo, R. P., Slivka, W. A., & Sciurba, F. C. (2007) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.1080/15412550701246658 · Cited by 144
Reducing Cardiovascular Risk Factors in Postmenopausal Women through a Lifestyle Change Intervention
Carels, R. A., Darby, L. A., Cacciapaglia, H. M., & Douglass, O. M. (2004) · Journal of Women's Health · doi:10.1089/154099904323087105 · Cited by 85
“Pair-sample t tests indicated that daily calories expended from physical activity decreased significantly t(37) 3.”
A combined heart rate and movement sensor: proof of concept and preliminary testing study
Rennie, K., Rowsell, T., Jebb, S., Holburn, D., & Wareham, N. (2000) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1600973 · Cited by 83
“In addition there are questions about the accuracy of this technique (Fehling et al, 1999; Jakicic et al, 1999).”
MethodPredicting walking METs and energy expenditure from speed or accelerometry
BROOKS, A. G., GUNN, S. M., WITHERS, R. T., GORE, C. J., & PLUMMER, J. L. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000170074.19649.0e · Cited by 73
Carels, R. A., Young, K. M., Coit, C., Clayton, A. M., Spencer, A., & Hobbs, M. (2008) · Eating Behaviors · doi:10.1016/j.eatbeh.2007.12.003 · Cited by 50
Metadata
- Authors
- FEHLING, P. C., SMITH, D. L., WARNER, S. E., & DALSKY, G. P.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1999-01
- Volume
- 31
- Issue
- 1
- Pages
- 171-175
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2074924751
- Cited by
- 85
- References
- 2
- FWCI
- 1.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.