Validity, reliability, and calibration of the Tritrac accelerometer as a measure of physical activity

NICHOLS, JEANNE F., MORGAN, CINDY G., SARKIN, JULIE A., SALLIS, JAMES F., CALFAS, KAREN J.·1999·Medicine & Science in Sports & Exercise

Abstract

PURPOSE: The purposes of this study were to assess the validity and reliability of the Tritrac R3D accelerometer during treadmill walking and running and then to calibrate the instrument. METHODS: The Tritrac was assessed on 60 young adults (23.4 +/- 2.9 yr) during treadmill walking and running at 3.2, 6.4, and 9.7 km x h(-1). The calibration was carried out by identifying ranges of Tritrac raw data (vector magnitude) values corresponding to light (2-3.9 MET), moderate (4-7 MET), and vigorous (>7 MET) physical activity. Energy expenditure (EE), measured by indirect calorimetry, served as the criterion measure. RESULTS: Interinstrument intraclass reliability coefficients for Tritracs worn on the right and left hip ranged from 0.73-0.87, while intersession coefficients demonstrated high reliability for all speeds (R = 0.87-0.92). Paired t-tests comparing mean accelerometer counts at 6.4 km x h(-1), 0% grade (2647 +/- 456), and 6.4 km x h(-1), 5% grade (2635 +/- 435) demonstrated no significant difference (P > 0.05). Mean differences between EE measured by indirect calorimetry and that estimated by the Tritrac ranged from 0.0082 kcal x kg(-1) x min(-1) at 3.2 km x h(-1) to 0.0320 kcal x kg(-1) x min(-1) at 9.7 km x h(-1), with the Tritrac consistently overestimating EE during horizontal treadmill walking. The relationship between vector magnitude and EE across all speeds was highly linear (R2 = 0.90, SEE = 0.014 kcal x kg(-1) x min(-1)), with little overlap between light, moderate, and vigorous categories. The mean vector magnitudes at 2, 4, and 7 MET were 650, 1772, and 3455, respectively. CONCLUSIONS: These data indicate that the Tritrac is highly reliable from day to day and is sensitive to changes in speed but not grade. Furthermore, the Tritrac accurately distinguishes various intensities of walking and jogging on level ground. With limitations, these cut-points can be used to categorize light, moderate, and vigorous physical activity and to estimate EE.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00005768-199906000-00022

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 178

Metadata

Authors
NICHOLS, J. F., MORGAN, C. G., SARKIN, J. A., SALLIS, J. F., & CALFAS, K. J.
Venue
Medicine & Science in Sports & Exercise
Published
1999-06
Volume
31
Issue
6
Pages
908-912
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2005442031
Cited by
178
References
1
FWCI
4.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validity, reliability, and calibration of the Tritrac accelerometer as a measure of physical activity. https://app.cochat.ai/papers/10.1097/00005768-199906000-00022
The paper
NICHOLS, J. F., MORGAN, C. G., SARKIN, J. A., SALLIS, J. F., & CALFAS, K. J. (1999). Validity, reliability, and calibration of the Tritrac accelerometer as a measure of physical activity. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-199906000-00022

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.