The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Validity, reliability, and calibration of the Tritrac accelerometer as a measure of physical activity
Abstract
PURPOSE: The purposes of this study were to assess the validity and reliability of the Tritrac R3D accelerometer during treadmill walking and running and then to calibrate the instrument. METHODS: The Tritrac was assessed on 60 young adults (23.4 +/- 2.9 yr) during treadmill walking and running at 3.2, 6.4, and 9.7 km x h(-1). The calibration was carried out by identifying ranges of Tritrac raw data (vector magnitude) values corresponding to light (2-3.9 MET), moderate (4-7 MET), and vigorous (>7 MET) physical activity. Energy expenditure (EE), measured by indirect calorimetry, served as the criterion measure. RESULTS: Interinstrument intraclass reliability coefficients for Tritracs worn on the right and left hip ranged from 0.73-0.87, while intersession coefficients demonstrated high reliability for all speeds (R = 0.87-0.92). Paired t-tests comparing mean accelerometer counts at 6.4 km x h(-1), 0% grade (2647 +/- 456), and 6.4 km x h(-1), 5% grade (2635 +/- 435) demonstrated no significant difference (P > 0.05). Mean differences between EE measured by indirect calorimetry and that estimated by the Tritrac ranged from 0.0082 kcal x kg(-1) x min(-1) at 3.2 km x h(-1) to 0.0320 kcal x kg(-1) x min(-1) at 9.7 km x h(-1), with the Tritrac consistently overestimating EE during horizontal treadmill walking. The relationship between vector magnitude and EE across all speeds was highly linear (R2 = 0.90, SEE = 0.014 kcal x kg(-1) x min(-1)), with little overlap between light, moderate, and vigorous categories. The mean vector magnitudes at 2, 4, and 7 MET were 650, 1772, and 3455, respectively. CONCLUSIONS: These data indicate that the Tritrac is highly reliable from day to day and is sensitive to changes in speed but not grade. Furthermore, the Tritrac accurately distinguishes various intensities of walking and jogging on level ground. With limitations, these cut-points can be used to categorize light, moderate, and vigorous physical activity and to estimate EE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cited by
Assessment of physical activity by self-report: Status, limitations, and future directions
Sallis, J. F., & Saelens, B. E. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.11082780 · Cited by 2,351
Self-citationConducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654
Practical Guide to Measuring Physical Activity
Sylvia, L. G., Bernstein, E. E., Hubbard, J. L., Keating, L., & Anderson, E. J. (2014) · Journal of the Academy of Nutrition and Dietetics · doi:10.1016/j.jand.2013.09.018 · Cited by 637
Metadata
- Authors
- NICHOLS, J. F., MORGAN, C. G., SARKIN, J. A., SALLIS, J. F., & CALFAS, K. J.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1999-06
- Volume
- 31
- Issue
- 6
- Pages
- 908-912
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2005442031
- Cited by
- 178
- References
- 1
- FWCI
- 4.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validity, reliability, and calibration of the Tritrac accelerometer as a measure of physical activity. https://app.cochat.ai/papers/10.1097/00005768-199906000-00022
- The paper
- NICHOLS, J. F., MORGAN, C. G., SARKIN, J. A., SALLIS, J. F., & CALFAS, K. J. (1999). Validity, reliability, and calibration of the Tritrac accelerometer as a measure of physical activity. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-199906000-00022
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.