Validity, reliability, and calibration of the Tritrac accelerometer as a measure of physical activity
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
PURPOSE: The purposes of this study were to assess the validity and reliability of the Tritrac R3D accelerometer during treadmill walking and running and then to calibrate the instrument. METHODS: The Tritrac was assessed on 60 young adults (23.4 +/- 2.9 yr) during treadmill walking and running at 3.2, 6.4, and 9.7 km x h(-1). The calibration was carried out by identifying ranges of Tritrac raw data (vector magnitude) values corresponding to light (2-3.9 MET), moderate (4-7 MET), and vigorous (>7 MET) physical activity. Energy expenditure (EE), measured by indirect calorimetry, served as the criterion measure. RESULTS: Interinstrument intraclass reliability coefficients for Tritracs worn on the right and left hip ranged from 0.73-0.87, while intersession coefficients demonstrated high reliability for all speeds (R = 0.87-0.92). Paired t-tests comparing mean accelerometer counts at 6.4 km x h(-1), 0% grade (2647 +/- 456), and 6.4 km x h(-1), 5% grade (2635 +/- 435) demonstrated no significant difference (P > 0.05). Mean differences between EE measured by indirect calorimetry and that estimated by the Tritrac ranged from 0.0082 kcal x kg(-1) x min(-1) at 3.2 km x h(-1) to 0.0320 kcal x kg(-1) x min(-1) at 9.7 km x h(-1), with the Tritrac consistently overestimating EE during horizontal treadmill walking. The relationship between vector magnitude and EE across all speeds was highly linear (R2 = 0.90, SEE = 0.014 kcal x kg(-1) x min(-1)), with little overlap between light, moderate, and vigorous categories. The mean vector magnitudes at 2, 4, and 7 MET were 650, 1772, and 3455, respectively. CONCLUSIONS: These data indicate that the Tritrac is highly reliable from day to day and is sensitive to changes in speed but not grade. Furthermore, the Tritrac accurately distinguishes various intensities of walking and jogging on level ground. With limitations, these cut-points can be used to categorize light, moderate, and vigorous physical activity and to estimate EE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessment of energy expenditure for physical activity using a triaxial accelerometer
BOUTEN, C. V., WESTERTERP, K. R., VERDUIN, M., & JANSSEN, J. D. (1994) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199412000-00016 · Cited by 451
SALLIS, J. F., STRIKMILLER, P. K., HARSHA, D. W., FELDMAN, H. A., EHLINGER, S., STONE, E. J., WILLISTON, J., & WOODS, S. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199607000-00011 · Cited by 426
Self-citationComparison of activity levels using the Caltrac?? accelerometer and five questionnaires
MILLER, D. J., FREEDSON, P. S., & KLINE, G. M. (1994) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199403000-00016 · Cited by 402
Estimation of energy expenditure by a portable accelerometer
MONTOYE, H. J., WASHBURN, R., SERVAIS, S., ERTL, A., WEBSTER, J. G., & NAGLE, F. J. (1983) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198315050-00010 · Cited by 225
The Caltrac accelerometer as a physical activity monitor for school-age children
SALLIS, J. F., BUONO, M. J., ROBY, J. J., CARLSON, D., & NELSON, J. A. (1990) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199010000-00023 · Cited by 201
Self-citationThe Validity of the Tritrac-R3D Activity Monitor for the Assessment of Physical Activity in Children
Welk, G. J., & Corbin, C. B. (1995) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.1995.10608834 · Cited by 144
Field trial of a three-dimensional activity monitor: comparison with self report
MATTHEWS, C. E., & FREEDSON, P. S. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199507000-00017 · Cited by 127
Accuracy and reliability of the Caltrac accelerometer for estimating energy expenditure
PAMBIANCO, G., WING, R. R., & ROBERTSON, R. (1990) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199012000-00020 · Cited by 93
Cited by
Assessment of physical activity by self-report: Status, limitations, and future directions
Sallis, J. F., & Saelens, B. E. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.11082780 · Cited by 2,351
Self-citationConducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Reliability and validity of the combined heart rate and movement sensor Actiheart
Brage, S., Brage, N., Franks, P. W., Ekelund, U., & Wareham, N. J. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602118 · Cited by 667
Calibration of Accelerometer Output for Adults
MATTHEW, C. E. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185659.11982.3d · Cited by 659
Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654
Practical Guide to Measuring Physical Activity
Sylvia, L. G., Bernstein, E. E., Hubbard, J. L., Keating, L., & Anderson, E. J. (2014) · Journal of the Academy of Nutrition and Dietetics · doi:10.1016/j.jand.2013.09.018 · Cited by 637
The Reliability of MinimaxX Accelerometers for Measuring Physical Activity in Australian Football
Boyd, L. J., Ball, K., & Aughey, R. J. (2011) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.6.3.311 · Cited by 556
Kumahara, H., Schutz, Y., Ayabe, M., Yoshioka, M., Yoshitake, Y., Shindo, M., Ishii, K., & Tanaka, H. (2004) · British Journal of Nutrition · doi:10.1079/bjn20031033 · Cited by 534
Physical activity levels in patients on hemodialysis and healthy sedentary controls
Johansen, K. L., Chertow, G. M., Ng, A. V., Mulligan, K., Carey, S., Schoenfeld, P. Y., & Kent-Braun, J. A. (2000) · Kidney International · doi:10.1046/j.1523-1755.2000.00116.x · Cited by 488
State of the Art Reviews: Measurement of Physical Activity in Children and Adolescents
Trost, S. G. (2007) · American Journal of Lifestyle Medicine · doi:10.1177/1559827607301686 · Cited by 404
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
“Study methodologies included the wearing of devices over the left and right hip [337, 370, 385, 387, 406, 413, 415, 417], over the hip and lower back [409], the wearing of devices side by side at the same location on the hip [301, 344, 411, 414, 416–418], devices worn at 3 intercostal space and just below the apex of…”
BackgroundMethodA comparative evaluation of three accelerometry-based physical activity monitors
WELK, G. J., BLAIR, S. N., WOOD, K., JONES, S., & THOMPSON, R. W. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00008 · Cited by 343
Validity of a Multi-Sensor Armband in Estimating Rest and Exercise Energy Expenditure
FRUIN, M. L., & RANKIN, J. W. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000128144.91337.38 · Cited by 342
Principles of Design and Analyses for the Calibration of Accelerometry-Based Activity Monitors
WELK, G. J. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185660.38335.de · Cited by 339
Skeletal muscle contractile and noncontractile components in young and older women and men
Kent-Braun, J. A., Ng, A. V., & Young, K. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.88.2.662 · Cited by 338
Accelerometer-based measures in physical activity surveillance: current practices and issues
Pedišić, Ž., & Bauman, A. (2015) · British Journal of Sports Medicine · doi:10.1136/bjsports-2013-093407 · Cited by 330
How Active Are People With Stroke?: Use of Accelerometers to Assess Physical Activity
Rand, D., Eng, J. J., Tang, P.-F., Jeng, J.-S., & Hung, C. (2009) · Stroke · doi:10.1161/strokeaha.108.523621 · Cited by 325
Talbot, L. A., Gaines, J. M., Huynh, T. N., & Metter, E. J. (2003) · Journal of the American Geriatrics Society · doi:10.1046/j.1532-5415.2003.51113.x · Cited by 315
Steinbeck, K. S. (2001) · Obesity Reviews · doi:10.1046/j.1467-789x.2001.00033.x · Cited by 312
Ainslie, P. N., Reilly, T., & Westerterp, K. R. (2003) · Sports Medicine · doi:10.2165/00007256-200333090-00004 · Cited by 309
The utility of the Digi-Walker step counter to assess daily physical activity patterns
WELK, G. J., DIFFERDING, J. A., THOMPSON, R. W., BLAIR, S. N., DZIURA, J., & HART, P. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00007 · Cited by 293
The Short-Term Effects of High-Dose Testosterone on Sleep, Breathing, and Function in Older Men
Liu, P. Y., Yee, B., Wishart, S. M., Jimenez, M., Jung, D. G., Grunstein, R. R., & Handelsman, D. J. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-030236 · Cited by 275
Johansen, K. L., Painter, P., Kent-Braun, J. A., Ng, A. V., Carey, S., Da Silva, M., & Chertow, G. M. (2001) · Kidney International · doi:10.1046/j.1523-1755.2001.00597.x · Cited by 265
Nichols, J. F., Morgan, C. G., Chabot, L. E., Sallis, J. F., & Calfas, K. J. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.10608878 · Cited by 203
Self-citationReliability, Validity, and Methodological Issues in Assessing Physical Activity in Older Adults
Rikli, R. E. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.11082791 · Cited by 180
Effect of chronic consumption of almonds on body weight in healthy humans
Hollis, J., & Mattes, R. (2007) · British Journal of Nutrition · doi:10.1017/s0007114507734608 · Cited by 176
“The accelerometer was worn on the waist from the time of rising in the morning to going to bed at night, and has been validated as a reliable method for measuring physical activity 14 .”
Validation of the Telephone and In-Person Interview Versions of the 7-Day PAR
HAYDEN-WADE, H. A., COLEMAN, K. J., SALLIS, J. F., & ARMSTRONG, C. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000064941.43869.4e · Cited by 164
Self-citationPhysical activity and exercise: Recent advances and current challenges.
Dubbert, P. M. (2002) · Journal of Consulting and Clinical Psychology · doi:10.1037//0022-006x.70.3.526 · Cited by 159
Liu, P. Y., Wishart, S. M., & Handelsman, D. J. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.87.7.8630 · Cited by 112
Weight Loss and Exercise: Implications for Muscle Lipid Metabolism and Insulin Action
BERGGREN, J. R., HULVER, M. W., DOHM, G. L., & HOUMARD, J. A. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000074670.03001.98 · Cited by 79
“In adults, other laboratory-based studies have compared accelerometers to energy expenditure during physical activity (5,15,26,27).”
BackgroundSlootmaker, S. M., Chin A Paw, M. J. M., Schuit, A. J., Van Mechelen, W., & Koppes, L. L. J. (2009) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2007.00740.x · Cited by 69
“The observed correlations for the PAM and Actigraph during walking are high compared with previous reports of accelerometers, where correlations (r2) were found ranging from 0.48 to 0.88 (Melanson & Freedson, 1995; Freedson et al., 1998; Nichols et al., 2000; Welk et al., 2000; Brooks et al., 2005).”
BackgroundResultInfluential
Metadata
- Authors
- NICHOLS, J. F., MORGAN, C. G., SARKIN, J. A., SALLIS, J. F., & CALFAS, K. J.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1999-06
- Volume
- 31
- Issue
- 6
- Pages
- 908-912
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2005442031
- Cited by
- 178
- References
- 9
- FWCI
- 4.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.