Validity, reliability, and calibration of the Tritrac accelerometer as a measure of physical activity
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
PURPOSE: The purposes of this study were to assess the validity and reliability of the Tritrac R3D accelerometer during treadmill walking and running and then to calibrate the instrument. METHODS: The Tritrac was assessed on 60 young adults (23.4 +/- 2.9 yr) during treadmill walking and running at 3.2, 6.4, and 9.7 km x h(-1). The calibration was carried out by identifying ranges of Tritrac raw data (vector magnitude) values corresponding to light (2-3.9 MET), moderate (4-7 MET), and vigorous (>7 MET) physical activity. Energy expenditure (EE), measured by indirect calorimetry, served as the criterion measure. RESULTS: Interinstrument intraclass reliability coefficients for Tritracs worn on the right and left hip ranged from 0.73-0.87, while intersession coefficients demonstrated high reliability for all speeds (R = 0.87-0.92). Paired t-tests comparing mean accelerometer counts at 6.4 km x h(-1), 0% grade (2647 +/- 456), and 6.4 km x h(-1), 5% grade (2635 +/- 435) demonstrated no significant difference (P > 0.05). Mean differences between EE measured by indirect calorimetry and that estimated by the Tritrac ranged from 0.0082 kcal x kg(-1) x min(-1) at 3.2 km x h(-1) to 0.0320 kcal x kg(-1) x min(-1) at 9.7 km x h(-1), with the Tritrac consistently overestimating EE during horizontal treadmill walking. The relationship between vector magnitude and EE across all speeds was highly linear (R2 = 0.90, SEE = 0.014 kcal x kg(-1) x min(-1)), with little overlap between light, moderate, and vigorous categories. The mean vector magnitudes at 2, 4, and 7 MET were 650, 1772, and 3455, respectively. CONCLUSIONS: These data indicate that the Tritrac is highly reliable from day to day and is sensitive to changes in speed but not grade. Furthermore, the Tritrac accurately distinguishes various intensities of walking and jogging on level ground. With limitations, these cut-points can be used to categorize light, moderate, and vigorous physical activity and to estimate EE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessment of energy expenditure for physical activity using a triaxial accelerometer
BOUTEN, C. V., WESTERTERP, K. R., VERDUIN, M., & JANSSEN, J. D. (1994) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199412000-00016 · Cited by 451
SALLIS, J. F., STRIKMILLER, P. K., HARSHA, D. W., FELDMAN, H. A., EHLINGER, S., STONE, E. J., WILLISTON, J., & WOODS, S. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199607000-00011 · Cited by 426
Self-citationComparison of activity levels using the Caltrac?? accelerometer and five questionnaires
MILLER, D. J., FREEDSON, P. S., & KLINE, G. M. (1994) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199403000-00016 · Cited by 402
Estimation of energy expenditure by a portable accelerometer
MONTOYE, H. J., WASHBURN, R., SERVAIS, S., ERTL, A., WEBSTER, J. G., & NAGLE, F. J. (1983) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198315050-00010 · Cited by 225
The Caltrac accelerometer as a physical activity monitor for school-age children
SALLIS, J. F., BUONO, M. J., ROBY, J. J., CARLSON, D., & NELSON, J. A. (1990) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199010000-00023 · Cited by 201
Self-citationThe Validity of the Tritrac-R3D Activity Monitor for the Assessment of Physical Activity in Children
Welk, G. J., & Corbin, C. B. (1995) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.1995.10608834 · Cited by 144
Field trial of a three-dimensional activity monitor: comparison with self report
MATTHEWS, C. E., & FREEDSON, P. S. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199507000-00017 · Cited by 127
Accuracy and reliability of the Caltrac accelerometer for estimating energy expenditure
PAMBIANCO, G., WING, R. R., & ROBERTSON, R. (1990) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199012000-00020 · Cited by 93
Cited by
Assessment of physical activity by self-report: Status, limitations, and future directions
Sallis, J. F., & Saelens, B. E. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.11082780 · Cited by 2,351
Self-citationConducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Reliability and validity of the combined heart rate and movement sensor Actiheart
Brage, S., Brage, N., Franks, P. W., Ekelund, U., & Wareham, N. J. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602118 · Cited by 667
Calibration of Accelerometer Output for Adults
MATTHEW, C. E. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185659.11982.3d · Cited by 659
Metadata
- Authors
- NICHOLS, J. F., MORGAN, C. G., SARKIN, J. A., SALLIS, J. F., & CALFAS, K. J.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1999-06
- Volume
- 31
- Issue
- 6
- Pages
- 908-912
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2005442031
- Cited by
- 178
- References
- 9
- FWCI
- 4.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.