CoChat

Technical reliability of the CSA activity monitor: The EarlyBird Study

Metcalf, BRAD S., Curnow, John S. H., Evans, Colin, Voss, Linda D., Wilkin, Terence J. · 2002 · Medicine & Science in Sports & Exercise
Cited by 142

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

PURPOSE: To evaluate the technical performance of the CSA accelerometer-based activity monitor. METHODS: Twenty-three CSA monitors were subjected to intra- and inter-instrument variability tests by controlled trials using a motorized turntable. The CSA monitor measures change in acceleration, and precision was tested by producing sinusoidal variations in speed around two fixed baseline speeds (fast and medium). The angle of the monitor to the line of force along the radius of the turntable was varied using tilted blocks. Three sets of tests were carried out. 1. Intra-instrument variability: seven monitors were tested three times in each of the four quadrants. 2. All 23 monitors were used for inter-instrument tests. 3. The effects of tilt at 15 degrees, 30 degrees, and 45 degrees were carried out on six monitors. RESULTS: Intra-instrument coefficients of variation (CV) never exceeded 2% for fast or medium speed and achieved "between run" intra-class correlation coefficients (ICC) of 0.92 and 0.84 respectively. There were no significant differences between the monitors in terms of repeatability (fast: = 0.97, medium: = 0.77). Although there were significant differences between monitors in terms of mean score, inter-instrument variability did not exceed 5% at either speed. Inter-batch ICCs ranged from 0.87 to 0.98 for fast and from 0.71 to 0.99 for medium. The angle test results corresponded closely to those predicted theoretically, with a loss in mean score of only 6% when the monitor was tilted from 0 degrees to 15 degrees. CONCLUSION: The CSA monitor provides a precise tool for measuring changes in acceleration in laboratory settings. Technically, the device performs well, and is likely to prove a useful tool in the assessment of physical activity in children and adults.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00005768-200209000-00022

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 142

Metadata

Authors
Metcalf, B. S., Curnow, J. S. H., Evans, C., Voss, L. D., & Wilkin, T. J.
Venue
Medicine & Science in Sports & Exercise
Published
2002-09
Volume
34
Issue
9
Pages
1533-1537
ISSN
0195-9131 (ISSN-L)
OpenAlex
W1970283917
Cited by
142
References
1
FWCI
3.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Technical reliability of the CSA activity monitor: The EarlyBird Study. https://app.cochat.ai/papers/10.1097/00005768-200209000-00022
The paper
Metcalf, B. S., Curnow, J. S. H., Evans, C., Voss, L. D., & Wilkin, T. J. (2002). Technical reliability of the CSA activity monitor: The EarlyBird Study. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-200209000-00022

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.