Technical reliability of the CSA activity monitor: The EarlyBird Study
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate the technical performance of the CSA accelerometer-based activity monitor. METHODS: Twenty-three CSA monitors were subjected to intra- and inter-instrument variability tests by controlled trials using a motorized turntable. The CSA monitor measures change in acceleration, and precision was tested by producing sinusoidal variations in speed around two fixed baseline speeds (fast and medium). The angle of the monitor to the line of force along the radius of the turntable was varied using tilted blocks. Three sets of tests were carried out. 1. Intra-instrument variability: seven monitors were tested three times in each of the four quadrants. 2. All 23 monitors were used for inter-instrument tests. 3. The effects of tilt at 15 degrees, 30 degrees, and 45 degrees were carried out on six monitors. RESULTS: Intra-instrument coefficients of variation (CV) never exceeded 2% for fast or medium speed and achieved "between run" intra-class correlation coefficients (ICC) of 0.92 and 0.84 respectively. There were no significant differences between the monitors in terms of repeatability (fast: = 0.97, medium: = 0.77). Although there were significant differences between monitors in terms of mean score, inter-instrument variability did not exceed 5% at either speed. Inter-batch ICCs ranged from 0.87 to 0.98 for fast and from 0.71 to 0.99 for medium. The angle test results corresponded closely to those predicted theoretically, with a loss in mean score of only 6% when the monitor was tilted from 0 degrees to 15 degrees. CONCLUSION: The CSA monitor provides a precise tool for measuring changes in acceleration in laboratory settings. Technically, the device performs well, and is likely to prove a useful tool in the assessment of physical activity in children and adults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Validity of the computer science and applications (CSA) activity monitor in children
TROST, S. G., WARD, D. S., MOOREHEAD, S. M., WATSON, P. D., RINER, W., & BURKE, J. R. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199804000-00023 · Cited by 769 · cited 2×
“Treadmill studies have concluded that the CSA monitor is reproducible (16), but as treadmills incur their own error they cannot reveal the intrinsic performance of the monitor.”
Background
Cited by
Calibration of two objective measures of physical activity for children
Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008) · Journal of Sports Sciences · doi:10.1080/02640410802334196 · Cited by 2,677
Conducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Physical activity levels and patterns of 9- and 15-yr-old European children
RIDDOCH, C. J., BO ANDERSEN, L., WEDDERKOPP, N., HARRO, M., KLASSON-HEGGEBØ, L., SARDINHA, L. B., COOPER, A. R., & EKELUND, U. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000106174.43932.92 · Cited by 900
Validation of the GENEA Accelerometer
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820513be · Cited by 625
Risk factors for childhood overweight: A prospective study from birth to 9.5 years
Agras, W. S., Hammer, L. D., McNicholas, F., & Kraemer, H. C. (2004) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2004.03.023 · Cited by 566
Esliger, D. W., Copeland, J. L., Barnes, J. D., & Tremblay, M. S. (2005) · Journal of Physical Activity and Health · doi:10.1123/jpah.2.3.366 · Cited by 388
Reexamination of Validity and Reliability of the CSA Monitor in Walking and Running
BRAGE, S., WEDDERKOPP, N., FRANKS, P. W., BO ANDERSEN, L., & FROBERG, K. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000079078.62035.ec · Cited by 347
Principles of Design and Analyses for the Calibration of Accelerometry-Based Activity Monitors
WELK, G. J. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185660.38335.de · Cited by 339
Accelerometer-based measures in physical activity surveillance: current practices and issues
Pedišić, Ž., & Bauman, A. (2015) · British Journal of Sports Medicine · doi:10.1136/bjsports-2013-093407 · Cited by 330
Reliability of the Actigraph GT3X+ Accelerometer in Adults under Free-Living Conditions
Aadland, E., & Ylvisåker, E. (2015) · PLOS ONE · doi:10.1371/journal.pone.0134606 · Cited by 313
Verloigne, M., Van Lippevelde, W., Maes, L., Yildirim, M., Chinapaw, M., Manios, Y., Androutsos, O., Kovacs, E., Bringolf-Isler, B., Brug, J., et al. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-34 · Cited by 258
Technical Reliability Assessment of Three Accelerometer Models in a Mechanical Setup
ESLIGER, D. W., & TREMBLAY, M. S. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000239394.55461.08 · Cited by 244
Metcalf, B. S., Hosking, J., Jeffery, A. N., Voss, L. D., Henley, W., & Wilkin, T. J. (2011) · Archives of Disease in Childhood · doi:10.1136/adc.2009.175927 · Cited by 241
Self-citationPortable Global Positioning Units to Complement Accelerometry-Based Physical Activity Monitors
RODRÍGUEZ, D. A., BROWN, A. L., & TROPED, P. J. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185297.72328.ce · Cited by 218
Riddoch, C., Edwards, D., Page, A., Froberg, K., Anderssen, S. A., Wedderkopp, N., Brage, S., Cooper, A. R., Sardinha, L. B., Harro, M., et al. (2005) · Journal of Physical Activity and Health · doi:10.1123/jpah.2.1.115 · Cited by 207
Technical variability of the GT3X accelerometer
Santos-Lozano, A., Marín, P. J., Torres-Luque, G., Ruiz, J. R., Lucía, A., & Garatachea, N. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.02.005 · Cited by 180
“In our study the ICC observed across frequencies for the Y, X, nd Z axes were relatively high [14], and are in agreement by those eported by other studies [7,12].”
BackgroundResultComparing the performance of three generations of ActiGraph accelerometers
Rothney, M. P., Apker, G. A., Song, Y., & Chen, K. Y. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90641.2008 · Cited by 177
Comparison of PAEE from Combined and Separate Heart Rate and Movement Models in Children
Corder, K., Brage, S., Wareham, N. J., & Ekelund, U. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000176466.78408.cc · Cited by 170
International children's accelerometry database (ICAD): Design and methods
Sherar, L. B., Griew, P., Esliger, D. W., Cooper, A. R., Ekelund, U., Judge, K., & Riddoch, C. (2011) · BMC Public Health · doi:10.1186/1471-2458-11-485 · Cited by 162
“These Actigraph models have demonstrated acceptable levels of technical reliability [25-28].”
BackgroundComparative validation of the IPAQ and the 7-Day PAR among women diagnosed with breast cancer
Johnson-Kozlow, M., Sallis, J. F., Gilpin, E. A., Rock, C. L., & Pierce, J. P. (2006) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-3-7 · Cited by 160
Rodríguez, D. A., Cho, G.-H., Evenson, K. R., Conway, T. L., Cohen, D., Ghosh-Dastidar, B., Pickrel, J. L., Veblen-Mortenson, S., & Lytle, L. A. (2012) · Health & Place · doi:10.1016/j.healthplace.2011.08.020 · Cited by 159
“Previous studies have demonstrated the ActiGraph to be a technically reliable instrument, able to detect differing levels of physical activity intensity (Metcalf et al., 2002; Welk et al., 2004).”
BackgroundProtocols for evaluating equivalency of accelerometry-based activity monitors
WELK, G. J., MCCLAIN, J., & AINSWORTH, B. E. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399d8f · Cited by 124
“, turntables, wheels, vibration tables, or shaker tables) to impart a standardized movement or acceleration to multiple units of a monitor model (6,10,14, 21,24,27).”
BackgroundDisparities in Youth Physical Activity in the United States: 2003–2006
GORTMAKER, S. L., LEE, R., CRADOCK, A. L., SOBOL, A. M., DUNCAN, D. T., & WANG, Y. C. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31823fb254 · Cited by 106
Slootmaker, S. M., Chin A Paw, M. J. M., Schuit, A. J., Van Mechelen, W., & Koppes, L. L. J. (2009) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2007.00740.x · Cited by 69
“80), which is similar to the range of values reported previously for the CSA (Metcalf et al., 2002) and Tritrac (Powell et al.”
BackgroundMethodResultInfluential
Metadata
- Authors
- Metcalf, B. S., Curnow, J. S. H., Evans, C., Voss, L. D., & Wilkin, T. J.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2002-09
- Volume
- 34
- Issue
- 9
- Pages
- 1533-1537
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1970283917
- Cited by
- 142
- References
- 1
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.