Field evaluation of energy expenditure in women using Tritrac accelerometers
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PURPOSE: To investigate the use of Tritrac accelerometers to measure energy expenditure (EE) of various activities for women in the field setting, as compared with portable indirect calorimetry. METHODS: Twenty women (age 20-29) performed a choreographed routine of six activities (walking, jogging, stair climbing, walking on an incline, stationary cycling, and arm ergometry) while wearing a Tritrac-R3D accelerometer (Hemokinetics Inc., Madison WI) and the Cosmed K4b(2) portable metabolic cart (Cosmed, Rome, Italy). RESULTS: Comparing the mean error scores (K4b(2) - Tritrac), the Tritrac overestimated the EE (kcal x min(-1)) of walking (-1.45) and jogging (-1.75), whereas underestimating the EE of stair climbing (2.76), stationary cycling (2.75), and arm ergometry (1.20). Walking on an incline showed the lowest mean error score (-0.11). Intraclass correlations were moderate for walking (r = 0.568, < 0.05), jogging (r = 0.666, < 0.05), and stairs (r = 0.503, < 0.05) but for the other activities ranged from r = 0.290 ( > 0.05) to r = 0.480 ( < 0.05). The raw data from the Tritrac was applied to a previously developed nonlinear model to adjust the Tritrac scores to the standard of whole-room indirect calorimetry. This resulted in statistically significant improvements in the agreement between the adjusted Tritrac value and the K4b for walking, jogging, and walking on an incline ( < 0.05). CONCLUSION: When compared with portable indirect calorimetry, the Tritrac overestimates the EE of walking and jogging, whereas underestimating that of stair climbing, stationary cycling, and arm ergometry. This limits the use of such a technique to measure EE in the field. The main issues appear to be the type and intensity of the activity and the need for movement in order for the Tritrac to register EE. Activity specific linear regression equations are proposed as a tool to improve the measurement of EE using the Tritrac in the field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Leon, A. S. (1987) · JAMA · doi:10.1001/jama.258.17.2388 · Cited by 842
Cited by
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
WILSON, R. P., WHITE, C. R., QUINTANA, F., HALSEY, L. G., LIEBSCH, N., MARTIN, G. R., & BUTLER, P. J. (2006) · Journal of Animal Ecology · doi:10.1111/j.1365-2656.2006.01127.x · Cited by 797
“give the best correlation with which may, at least in part, explain our high correlation coefficients compared to those from other studies using mono- or biaxial transducers (Campbell et al. 2002; Hoos et al. 2003).”
ResultCalibration of Accelerometer Output for Adults
MATTHEW, C. E. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185659.11982.3d · Cited by 659
Practical Guide to Measuring Physical Activity
Sylvia, L. G., Bernstein, E. E., Hubbard, J. L., Keating, L., & Anderson, E. J. (2014) · Journal of the Academy of Nutrition and Dietetics · doi:10.1016/j.jand.2013.09.018 · Cited by 637
Quantifying physical activity in daily life with questionnaires and motion sensors in COPD
Pitta, F., Troosters, T., Probst, V. S., Spruit, M. A., Decramer, M., & Gosselink, R. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00064105 · Cited by 473
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
“1%)) [282, 328, 341, 358, 367, 369, 370, 375, 376, 380, 382, 383, 385, 387]; (METs over specified durations; Additional file 1: figure S3g (-67.”
BackgroundValidity of a Multi-Sensor Armband in Estimating Rest and Exercise Energy Expenditure
FRUIN, M. L., & RANKIN, J. W. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000128144.91337.38 · Cited by 342
Principles of Design and Analyses for the Calibration of Accelerometry-Based Activity Monitors
WELK, G. J. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185660.38335.de · Cited by 339
Ainslie, P. N., Reilly, T., & Westerterp, K. R. (2003) · Sports Medicine · doi:10.2165/00007256-200333090-00004 · Cited by 309
Brage, S., Ekelund, U., Brage, N., Hennings, M. A., Froberg, K., Franks, P. W., & Wareham, N. J. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00092.2006 · Cited by 303
Validity of activity monitors in health and chronic disease: a systematic review
Van Remoortel, H., Giavedoni, S., Raste, Y., Burtin, C., Louvaris, Z., Gimeno-Santos, E., Langer, D., Glendenning, A., Hopkinson, N. S., Vogiatzis, I., et al. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-84 · Cited by 277
Garcia-Rio, F., Lores, V., Mediano, O., Rojo, B., Hernanz, A., López-Collazo, E., & Alvarez-Sala, R. (2009) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200812-1873oc · Cited by 275
Adolescent Patterns of Physical ActivityDifferences by Gender, Day, and Time of Day
JAGO, R., ANDERSON, C., BARANOWSKI, T., & WATSON, K. (2005) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2005.02.007 · Cited by 250
Steele, B. G., Belza, B., Cain, K., Warms, C., Coppersmith, J., & Howard, J. (2003) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2003.10.0045 · Cited by 176
“For example, the Tritrac accelerometer has been shown to overestimate the energy expenditure of walking and jogging and to underestimate the energy expenditure of stair climbing, stationary cycling, and arm ergometry [24].”
BackgroundPosition-sensing technologies for movement analysis in stroke rehabilitation
Zheng, H., Black, N. D., & Harris, N. D. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344720 · Cited by 165
On Higher Ground: How Well Can Dynamic Body Acceleration Determine Speed in Variable Terrain?
Bidder, O. R., Qasem, L. A., & Wilson, R. P. (2012) · PLoS ONE · doi:10.1371/journal.pone.0050556 · Cited by 57
“Whilst equipped with accelerometers, they travelled a defined distance of 10 m, delineated by markers on the ground, at a range of speeds incorporating three different gaits employed by humans; walk, jog and run [64,65,66].”
Physical Activity and Preterm Birth: A Literature Review
Domingues, M. R., Matijasevich, A., & Barros, A. J. D. (2009) · Sports Medicine · doi:10.2165/11317900-000000000-00000 · Cited by 56
Metadata
- Authors
- CAMPBELL, K. L., CROCKER, P. R. E., & MCKENZIE, D. C.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2002-10
- Volume
- 34
- Issue
- 10
- Pages
- 1667-1674
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2093763097
- Cited by
- 107
- References
- 2
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.