Calibration of Accelerometer Output for Adults
Abstract
This paper reviews the collective experience of monitor calibration studies in adults and seeks to answer the following questions: What has been done? What have we learned? What could be done to further enhance the comparability of results from future calibration research? Calibration studies in adults have typically used oxygen consumption as a criterion measure, similar types of source activities, and linear regression to obtain prediction equations that calibrate the activity counts to measured activity intensity levels. However, the methodological diversity of these studies has produced a great deal of variation in the resulting prediction equations and cut points, even when using the same monitor. Thus, data obtained from a relatively robust activity monitoring technology that captures many dynamic physical activities reasonably well have been splintered by the calibration process into a wide range of summary measures that are much less comparable than they could otherwise be. This heterogeneity in calibration results reduces our ability to interpret data obtained from accelerometers between different research groups, across the life span, between populations, and probably between the different monitor types. This report reviews and critiques methods typically used for developing calibration equations and determining activity count cut points for identifying specific intensities of PA among adults, and it highlights the need for flexible research methods that can enhance the comparability of results from future calibration studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Role of Nonexercise Activity Thermogenesis in Resistance to Fat Gain in Humans
Levine, J. A., Eberhardt, N. L., & Jensen, M. D. (1999) · Science · doi:10.1126/science.283.5399.212 · Cited by 997
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Interindividual variation in posture allocation: possible role in human obesity
Levine, J. A., Lanningham-Foster, L. M., McCrady, S. K., Krizan, A. C., Olson, L. R., Kane, P. H., Jensen, M. D., & Clark, M. M. (2005) · Science · doi:10.1126/science.1106561 · Cited by 705
Integration of physiological and accelerometer data to improve physical activity assessment
STRATH, S. J., BRAGE, S., & EKELUND, U. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185650.68232.3f · Cited by 126
Research works printed but not linked: 35
- Ainsworth, 2000, Comparison of three methods for measuring the time spent in physical activity., Med. Sci. Sports Exerc, 32, 457, 10.1097/00005768-200009001-00004 · DOI · Paper page
- Ayen, 1988, Estimation of energy expenditure with a simulated three-dimensional accelerometer., J. Ambul. Monit, 1, 293
- Bassett, 2000, Validity and reliability issues in objective monitoring of physical activity., Res. Q. Exerc. Sport, 71, S30, 10.1080/02701367.2000.11082783 · DOI · Paper page
- Bassett, 2000, Validity of four motion sensors in measuring moderate intensity physical activity., Med. Sci. Sports Exerc, 32, 471, 10.1097/00005768-200009001-00006 · DOI · Paper page
- Bouten, 1997, A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity., IEEE Trans. Biomed. Eng, 44, 136, 10.1109/10.554760 · DOI · Paper page
- Bouten, 1996, Daily physical activity assessment: comparison between movement registration and doubly labeled water., J. Appl. Physiol, 81, 1019, 10.1152/jappl.1996.81.2.1019 · DOI · Paper page
- Brage, 2003, Reexamination of validity and reliability of the CSA monitor in walking and running., Med. Sci. Sports Exerc, 35, 1447, 10.1249/01.MSS.0000079078.62035.EC · DOI · Paper page
- Campbell, 2002, Field evaluation of energy expenditure in women using Tritrac accelerometers., Med. Sci. Sports Exerc, 34, 1667, 10.1097/00005768-200210000-00020 · DOI
- Chen, 1997, Improving energy expenditure estimation by using a triaxial accelerometer., J. Appl. Physiol, 83, 2112, 10.1152/jappl.1997.83.6.2112 · DOI
- Freedson, 2000, Objective monitoring of physical activity using motion sensors and heart rate., Res. Q. Exerc. Sport, 71, S21, 10.1080/02701367.2000.11082782 · DOI · Paper page
- Hendelman, 2000, Validity of accelerometry for the assessment of moderate intensity physical activity in the field., Med. Sci. Sports Exerc, 32, 442, 10.1097/00005768-200009001-00002 · DOI · Paper page
- Jakicic, 2004, Evaluation of the SenseWear Pro Armband to assess energy expenditure during exercise., Med. Sci. Sports Exerc, 36, 897, 10.1249/01.MSS.0000126805.32659.43 · DOI · Paper page
- King, 2004, Comparison of activity monitors to estimate energy cost of treadmill exercise., Med. Sci. Sports Exerc, 36, 1244, 10.1249/01.MSS.0000132379.09364.F8 · DOI
- Laporte, 1985, Assessment of physical activity in epidemiologic research: problems and prospects., Public Health Rep, 100, 131
- Leenders, 2003, Ability of different physical activity monitors to detect movement during treadmill walking., Int. J. Sports Med, 24, 43, 10.1055/s-2003-37196 · DOI
- Matthews, 2005, Development and testing of a short physical activity recall questionnaire., Med. Sci. Sports Exerc, 37, 986
- Matthews, 2002, Sources of variance in daily physical activity levels as measured by an accelerometer., Med. Sci. Sports Exerc, 34, 1376, 10.1097/00005768-200208000-00021 · DOI · Paper page
- Matthews, 2000, Comparing physical activity assessment methods in the Seasonal Variation of Blood Cholesterol Levels Study., Med. Sci. Sports Exerc, 32, 976, 10.1097/00005768-200005000-00015 · DOI
- Montoye, 1971, Estimation of habitual physical activity by questionnaire and interview., Am. J. Clin. Nutr, 24, 1113, 10.1093/ajcn/24.9.1113 · DOI
- Montoye, 2000, Introduction: evaluation of some measurements of physical activity and energy expenditure., Med. Sci. Sports Exerc, 32, S439, 10.1097/00005768-200009001-00001 · DOI
- Montoye, 1983, Estimation of energy expenditure by a portable accelerometer., Med. Sci. Sports Exerc, 15, 403, 10.1249/00005768-198315050-00010 · DOI · Paper page
- Nichols, 2000, Assessment of physical activity with the Computer Science and Applications, Inc. accelerometer: Laboratory versus field validation., Res. Q. Exerc. Sport, 71, 36, 10.1080/02701367.2000.10608878 · DOI · Paper page
- Nichols, 1999, Validity, reliability, and calibration of the Tritrac accelerometer as a measure of physical activity., Med. Sci. Sports Exerc, 31, 908, 10.1097/00005768-199906000-00022 · DOI · Paper page
- Puyau, 2002, Validation and calibration of physical activity monitors in children., Obes. Res, 10, 150, 10.1038/oby.2002.24 · DOI · Paper page
- Servais, 1984, Estimating Human Energy Expenditure Using an Accelerometer Device., J. Clin. Eng, 159, 10.1097/00004669-198404000-00015 · doi:10.1097/00004669-198404000-00015
- Strath, 2002, Validity of the simultaneous heart rate-motion sensor technique for measuring energy expenditure., Med. Sci. Sports Exerc, 34, 888, 10.1097/00005768-200205000-00025 · DOI
- Swartz, 2000, Estimation of energy expenditure using CSA accelerometers at hip and wrist sites., Med. Sci. Sports Exerc, 32, 450, 10.1097/00005768-200009001-00003 · DOI · Paper page
- Treuth, 2004, Defining accelerometer thresholds for activity intensities in adolescent girls., Med. Sci. Sports Exerc, 36, 1259
- Trost, Conducting accelerometer-based activity assessments in field-based research., Med. Sci. Sports Exerc, 37, S531, 10.1249/01.mss.0000185657.86065.98 · DOI · Paper page
- Welk, 2000, A comparative evaluation of three accelerometry-based physical activity monitors., Med. Sci. Sports Exerc, 32, 489, 10.1097/00005768-200009001-00008 · DOI · Paper page
- Westerterp, 1999, Physical activity assessment with accelerometers., Int. J. Obes. Relat. Metab. Disord, 23, S45, 10.1038/sj.ijo.0800883 · DOI · Paper page
- Westerterp, 2001, Pattern and intensity of physical activity., Nature, 410, 539, 10.1038/35069142 · DOI · Paper page
- Wong, 2003, The detection of gene-environment interaction for continuous traits: should we deal with measurement error by bigger studies or better measurement, Int. J. Epidemiol, 32, 51, 10.1093/ije/dyg002 · DOI · Paper page
- Yngve, 2003, Effect of monitor placement and of activity setting on the MTI accelerometer output., Med. Sci. Sports Exerc, 35, 320, 10.1249/01.MSS.0000048829.75758.A0 · DOI
- Zurlo, 1992, Spontaneous physical activity and obesity: cross-sectional and longitudinal studies in Pima Indians., Am. J. Physiol, 263, 296
Cited by
Amount of Time Spent in Sedentary Behaviors in the United States, 2003-2004
Matthews, C. E., Chen, K. Y., Freedson, P. S., Buchowski, M. S., Beech, B. M., Pate, R. R., & Troiano, R. P. (2008) · American Journal of Epidemiology · doi:10.1093/aje/kwm390 · Cited by 2,631
Validation of Accelerometer Wear and Nonwear Time Classification Algorithm
CHOI, L., LIU, Z., MATTHEWS, C. E., & BUCHOWSKI, M. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181ed61a3 · Cited by 1,804
Pahor, M., Guralnik, J. M., Ambrosius, W. T., Blair, S., Bonds, D. E., Church, T. S., Espeland, M. A., Fielding, R. A., Gill, T. M., Groessl, E. J., et al. (2014) · JAMA · doi:10.1001/jama.2014.5616 · Cited by 1,427
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Metadata
- Authors
- MATTHEW, C. E.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2005-11
- Volume
- 37
- Issue
- 11
- Pages
- S512-S522
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1970820481
- Cited by
- 659
- References
- 5
- FWCI
- 8.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calibration of Accelerometer Output for Adults. https://app.cochat.ai/papers/10.1249/01.mss.0000185659.11982.3d
- The paper
- MATTHEW, C. E. (2005). Calibration of Accelerometer Output for Adults. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/01.mss.0000185659.11982.3d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.