The DOI matches its Crossref record; 109 of the 109 references it cites were found in a registry or an index.
A Review of Risk Factors for Catheter-Related Bloodstream Infection Caused by Percutaneously Inserted, Noncuffed Central Venous Catheters: Implications for Preventive Strategies
Abstract
Strategies for preventing central venous catheter (CVC)-related bloodstream infection are most likely to be effective if guided by an understanding of the risk factors associated with these infections. In this critical review of published studies of risk factors for CVC-related bloodstream infection that were prospective and used multivariable techniques of data analysis or that were randomized trials of a preventive measure, a significantly increased risk of catheter-related bloodstream infection was associated with inexperience of the operator and nurse-to-patient ratio in the intensive care unit, catheter insertion with less than maximal sterile barriers, placement of a CVC in the internal jugular or femoral vein rather than subclavian vein, placement in an old site by guidewire exchange, heavy colonization of the insertion site or contamination of a catheter hub, and duration of CVC placement > 7 days. Prospective studies or randomized trials of control measures focusing on these risk factors have been shown to reduce risk significantly: formal training in CVC insertion and care, use of maximal sterile barriers at insertion, use of chlorhexidine rather than povidone-iodine for cutaneous antisepsis, applying a topical anti-infective cream or ointment or a chlorhexidine-impregnated dressing to the insertion site, and the use of novel catheters with an anti-infective surface or a contamination resistant hub. Better prospective studies of sufficient size to address all potential risk factors, including insertion site and hub colonization, insertion technique, and details of follow-up care, would enhance our understanding of the pathogenesis of CVC-related bloodstream infection and guide efforts to develop more effective strategies for prevention.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Szer, J. (1999) · Medical Journal of Australia · doi:10.5694/j.1326-5377.1999.tb127745.x · Cited by 3,353
Biomaterial-Centered Infection: Microbial Adhesion Versus Tissue Integration
Gristina, A. G. (1987) · Science · doi:10.1126/science.3629258 · Cited by 2,156
Merrer, J. (2001) · JAMA · doi:10.1001/jama.286.6.700 · Cited by 1,187
Pittet, D. (1994) · JAMA · doi:10.1001/jama.1994.03510440058033 · Cited by 926
Prevention of Intravascular Catheter–Related Infections
Mermel, L. A. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-132-5-200003070-00009 · Cited by 919
Secular trends in nosocomial primary bloodstream infections in the United States, 1980–1989.
Banerjee, S. N., Emori, T. G., Culver, D. H., Gaynes, R. P., Jarvis, W. R., Horan, T., Edwards, J. R., Tolson, J., Henderson, T., Martone, W. J., et al. (1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)90349-3 · Cited by 880
Prevention of Intravascular Catheter-Related Infections
(2021) · Indian Journal of Continuing Nursing Education · doi:10.4103/2230-7354.320831 · Cited by 855
Maki, D. G., Alvarado, C. J., & Ringer, M. (1991) · The Lancet · doi:10.1016/0140-6736(91)90479-9 · Cited by 845
Self-citationA Comparison of Two Antimicrobial-Impregnated Central Venous Catheters
Darouiche, R. O., Raad, I. I., Heard, S. O., Thornby, J. I., Wenker, O. C., Gabrielli, A., Berg, J., Khardori, N., Hanna, H., Hachem, R., et al. (1999) · New England Journal of Medicine · doi:10.1056/nejm199901073400101 · Cited by 804
Raad, I. I., Hohn, D. C., Gilbreath, B. J., Suleiman, N., Hill, L. A., Bruso, P. A., Marts, K., Mansfield, P. F., & Bodey, G. P. (1994) · Infection Control & Hospital Epidemiology · doi:10.1086/646902 · Cited by 774
Cited by
Guidelines for the prevention of intravascular catheter-related infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2011.01.003 · Cited by 1,066
Guidelines for the Prevention of Intravascular Catheter–Related Infections
O'Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Infection Control & Hospital Epidemiology · doi:10.1017/s0195941700080577 · Cited by 319
Self-citationGarnacho-Montero, J., Aldabó-Pallás, T., Palomar-Martínez, M., Vallés, J., Almirante, B., Garcés, R., Grill, F., Pujol, M., Arenas-Giménez, C., Mesalles, E., et al. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1204-7 · Cited by 150
A mouse model to evaluate the interface between skin and a percutaneous device
Isenhath, S. N., Fukano, Y., Usui, M. L., Underwood, R. A., Irvin, C. A., Marshall, A. J., Hauch, K. D., Ratner, B. D., Fleckman, P., & Olerud, J. E. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31391 · Cited by 59
Underwood, R. A., Usui, M. L., Zhao, G., Hauch, K. D., Takeno, M. M., Ratner, B. D., Marshall, A. J., Shi, X., Olerud, J. E., & Fleckman, P. (2011) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.33125 · Cited by 52
Metadata
- Authors
- SAFDAR, N., KLUGER, D. M., & MAKI, D. G.
- Venue
- Medicine
- Published
- 2002-11
- Volume
- 81
- Issue
- 6
- Pages
- 466-479
- ISSN
- 0025-7974 (ISSN-L)
- OpenAlex
- W2020990310
- Cited by
- 261
- References
- 109
- FWCI
- 12.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Review of Risk Factors for Catheter-Related Bloodstream Infection Caused by Percutaneously Inserted, Noncuffed Central Venous Catheters: Implications for Preventive Strategies. https://app.cochat.ai/papers/10.1097/00005792-200211000-00007
- The paper
- SAFDAR, N., KLUGER, D. M., & MAKI, D. G. (2002). A Review of Risk Factors for Catheter-Related Bloodstream Infection Caused by Percutaneously Inserted, Noncuffed Central Venous Catheters: Implications for Preventive Strategies. Medicine. https://doi.org/10.1097/00005792-200211000-00007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.